795例桡骨远端骨折内固定物取出与骨折特征的关系

IF 2.3 3区 医学 Q2 ORTHOPEDICS
Yener Yoğun, Uğur Bezirgan, Mehmet Batu Ertan, Mehmet Can Gezer, Mehmet Armangil
{"title":"795例桡骨远端骨折内固定物取出与骨折特征的关系","authors":"Yener Yoğun, Uğur Bezirgan, Mehmet Batu Ertan, Mehmet Can Gezer, Mehmet Armangil","doi":"10.1016/j.otsr.2025.104172","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.</p><p><strong>Hypothesis: </strong>The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.</p><p><strong>Materials and methods: </strong>We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022. The patients were divided into two groups: implant removed, and implant retained. The groups were examined for demographic data, follow-up periods, fracture classifications, and radiological parameters. Additionally, the patients were divided into groups and compared according to the Soong classification, which was determined according to implant placement. Indications for implant removal were also included in this study, and their relationships with other parameters were evaluated.</p><p><strong>Results: </strong>A total of 123 and 672 patients were included in the implant removed and retained groups, respectively. The average age of the implant removed group was significantly lower (p = 0.005). There were no significant differences between the two groups in terms of fracture classification or other radiological parameters. In the implant removed group, the rate of grade 2, according to the Soong classification, was statistically higher than that in the other groups (p = 0.019). Flexor tenosynovitis was the most common reason for implant removal.</p><p><strong>Conclusion: </strong>The Soong classification system is an important risk factor associated with implant removal. This risk may increase, particularly among young patients. Surgeons should consider placing the distal radius locking plate as proximally as possible to reduce the frequency of implant removal.</p><p><strong>Level of evidence: </strong>III; retrospective comparative study.</p>","PeriodicalId":54664,"journal":{"name":"Orthopaedics & Traumatology-Surgery & Research","volume":" ","pages":"104172"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The relationship between soong classification and fracture characteristics with implant removal for distal radius fractures: a comparative study of 795 cases.\",\"authors\":\"Yener Yoğun, Uğur Bezirgan, Mehmet Batu Ertan, Mehmet Can Gezer, Mehmet Armangil\",\"doi\":\"10.1016/j.otsr.2025.104172\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.</p><p><strong>Hypothesis: </strong>The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.</p><p><strong>Materials and methods: </strong>We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022. The patients were divided into two groups: implant removed, and implant retained. The groups were examined for demographic data, follow-up periods, fracture classifications, and radiological parameters. Additionally, the patients were divided into groups and compared according to the Soong classification, which was determined according to implant placement. Indications for implant removal were also included in this study, and their relationships with other parameters were evaluated.</p><p><strong>Results: </strong>A total of 123 and 672 patients were included in the implant removed and retained groups, respectively. The average age of the implant removed group was significantly lower (p = 0.005). There were no significant differences between the two groups in terms of fracture classification or other radiological parameters. In the implant removed group, the rate of grade 2, according to the Soong classification, was statistically higher than that in the other groups (p = 0.019). Flexor tenosynovitis was the most common reason for implant removal.</p><p><strong>Conclusion: </strong>The Soong classification system is an important risk factor associated with implant removal. This risk may increase, particularly among young patients. Surgeons should consider placing the distal radius locking plate as proximally as possible to reduce the frequency of implant removal.</p><p><strong>Level of evidence: </strong>III; retrospective comparative study.</p>\",\"PeriodicalId\":54664,\"journal\":{\"name\":\"Orthopaedics & Traumatology-Surgery & Research\",\"volume\":\" \",\"pages\":\"104172\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthopaedics & Traumatology-Surgery & Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.otsr.2025.104172\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedics & Traumatology-Surgery & Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.otsr.2025.104172","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

引言:虽然文献中没有共识,但人们认为song分类系统和骨折类型是桡骨远端骨折钢板取出的危险因素。假设:这项大规模研究的目的是评估桡骨远端骨折的song分类、骨折类型和植入物移除之间的关系。材料和方法:我们回顾性评估了2005年至2022年在我们诊所使用掌侧锁定钢板治疗桡骨远端骨折的795例患者。患者分为移除种植体组和保留种植体组。研究人员检查了这些组的人口统计数据、随访时间、骨折分类和放射学参数。此外,根据种植体放置位置确定的Soong分类对患者进行分组比较。本研究还包括种植体移除的指征,并评估其与其他参数的关系。结果:拔出种植体组123例,保留种植体组672例。拔除种植体组的平均年龄明显降低(p = 0.005)。两组在骨折分型或其他放射学参数方面无显著差异。拔除种植体组按Soong分级2级率显著高于其他组(p = 0.019)。屈肌腱滑膜炎是植入物移除的最常见原因。结论:Soong分类系统是种植体拔除的重要危险因素。这种风险可能会增加,尤其是在年轻患者中。外科医生应考虑将远端桡骨锁定钢板放置在尽可能近的位置,以减少内固定物取出的频率。证据等级:III;回顾性比较研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The relationship between soong classification and fracture characteristics with implant removal for distal radius fractures: a comparative study of 795 cases.

Introduction: Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.

Hypothesis: The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.

Materials and methods: We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022. The patients were divided into two groups: implant removed, and implant retained. The groups were examined for demographic data, follow-up periods, fracture classifications, and radiological parameters. Additionally, the patients were divided into groups and compared according to the Soong classification, which was determined according to implant placement. Indications for implant removal were also included in this study, and their relationships with other parameters were evaluated.

Results: A total of 123 and 672 patients were included in the implant removed and retained groups, respectively. The average age of the implant removed group was significantly lower (p = 0.005). There were no significant differences between the two groups in terms of fracture classification or other radiological parameters. In the implant removed group, the rate of grade 2, according to the Soong classification, was statistically higher than that in the other groups (p = 0.019). Flexor tenosynovitis was the most common reason for implant removal.

Conclusion: The Soong classification system is an important risk factor associated with implant removal. This risk may increase, particularly among young patients. Surgeons should consider placing the distal radius locking plate as proximally as possible to reduce the frequency of implant removal.

Level of evidence: III; retrospective comparative study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
26.10%
发文量
329
审稿时长
12.5 weeks
期刊介绍: Orthopaedics & Traumatology: Surgery & Research (OTSR) publishes original scientific work in English related to all domains of orthopaedics. Original articles, Reviews, Technical notes and Concise follow-up of a former OTSR study are published in English in electronic form only and indexed in the main international databases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信