{"title":"验证clearcalc对患者特异性QA的有效性。","authors":"Ignatius Komakech, Denis Okello, Awusi Kavuma, Bonny Abal, Annette Wygoda","doi":"10.1016/j.meddos.2024.12.003","DOIUrl":null,"url":null,"abstract":"<p><p>Uganda's only radiotherapy center is a very busy facility treating about 210 patients daily on three linear accelerators making it sometimes hard to have machine time for pretreatment QAs. This study was aimed at validating an independent calculation software, ClearCalc (ICS) for second checks of the treatment planning system (TPS) calculations. The validation of ICS started with simple phantom test plans consisting of square, irregular, open and wedged fields designed in the TPS and measured in phantoms. Doses and monitor units (MUs) calculated by ICS were compared with TPS calculated doses and with measured doses. ICS was then validated on clinically approved treatment plans: comparison with TPS calculations and with pretreatment QA measurements performed with electronic portal imaging devices (EPIDs) and analyzed using Gamma passing criteria of 3%/3 mm and 3%/2 mm. Results for test plans were within the passing level of 3.0% except for 2 outliers (-3.1% and 3.1%). As for the clinically approved treatment plans, they show good agreement between MUs (0.2 ± 1.8%), reference point doses (0.2 ±1.5%) and mean PTV doses (0.5 ± 1.4%). ICS calculated (3D) mean gamma pass rates were 98.1±1.6% and 98.4±1.0% for 3%/2 mm and 3%/3 mm criteria. No correlation was seen between gamma analysis results from ICS and EPID. This study validated ClearCalc on phantom and clinically approved plans. The result show that ICS based patients specific QA is quick, promising and potentially allows significant time saving that can be utilized for patient treatments.</p>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of clearcalc for efficient patient specific QA.\",\"authors\":\"Ignatius Komakech, Denis Okello, Awusi Kavuma, Bonny Abal, Annette Wygoda\",\"doi\":\"10.1016/j.meddos.2024.12.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Uganda's only radiotherapy center is a very busy facility treating about 210 patients daily on three linear accelerators making it sometimes hard to have machine time for pretreatment QAs. This study was aimed at validating an independent calculation software, ClearCalc (ICS) for second checks of the treatment planning system (TPS) calculations. The validation of ICS started with simple phantom test plans consisting of square, irregular, open and wedged fields designed in the TPS and measured in phantoms. Doses and monitor units (MUs) calculated by ICS were compared with TPS calculated doses and with measured doses. ICS was then validated on clinically approved treatment plans: comparison with TPS calculations and with pretreatment QA measurements performed with electronic portal imaging devices (EPIDs) and analyzed using Gamma passing criteria of 3%/3 mm and 3%/2 mm. Results for test plans were within the passing level of 3.0% except for 2 outliers (-3.1% and 3.1%). As for the clinically approved treatment plans, they show good agreement between MUs (0.2 ± 1.8%), reference point doses (0.2 ±1.5%) and mean PTV doses (0.5 ± 1.4%). ICS calculated (3D) mean gamma pass rates were 98.1±1.6% and 98.4±1.0% for 3%/2 mm and 3%/3 mm criteria. No correlation was seen between gamma analysis results from ICS and EPID. This study validated ClearCalc on phantom and clinically approved plans. The result show that ICS based patients specific QA is quick, promising and potentially allows significant time saving that can be utilized for patient treatments.</p>\",\"PeriodicalId\":49837,\"journal\":{\"name\":\"Medical Dosimetry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Dosimetry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.meddos.2024.12.003\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.meddos.2024.12.003","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
Validation of clearcalc for efficient patient specific QA.
Uganda's only radiotherapy center is a very busy facility treating about 210 patients daily on three linear accelerators making it sometimes hard to have machine time for pretreatment QAs. This study was aimed at validating an independent calculation software, ClearCalc (ICS) for second checks of the treatment planning system (TPS) calculations. The validation of ICS started with simple phantom test plans consisting of square, irregular, open and wedged fields designed in the TPS and measured in phantoms. Doses and monitor units (MUs) calculated by ICS were compared with TPS calculated doses and with measured doses. ICS was then validated on clinically approved treatment plans: comparison with TPS calculations and with pretreatment QA measurements performed with electronic portal imaging devices (EPIDs) and analyzed using Gamma passing criteria of 3%/3 mm and 3%/2 mm. Results for test plans were within the passing level of 3.0% except for 2 outliers (-3.1% and 3.1%). As for the clinically approved treatment plans, they show good agreement between MUs (0.2 ± 1.8%), reference point doses (0.2 ±1.5%) and mean PTV doses (0.5 ± 1.4%). ICS calculated (3D) mean gamma pass rates were 98.1±1.6% and 98.4±1.0% for 3%/2 mm and 3%/3 mm criteria. No correlation was seen between gamma analysis results from ICS and EPID. This study validated ClearCalc on phantom and clinically approved plans. The result show that ICS based patients specific QA is quick, promising and potentially allows significant time saving that can be utilized for patient treatments.
期刊介绍:
Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.