凸性特征的测量:一个跨学科的共识会议。

IF 1.7 3区 医学 Q2 NURSING
Janice M Beitz, Jan Colwell, Dorothy Doughty, Laurie McNichol, Mikel Gray
{"title":"凸性特征的测量:一个跨学科的共识会议。","authors":"Janice M Beitz, Jan Colwell, Dorothy Doughty, Laurie McNichol, Mikel Gray","doi":"10.1097/WON.0000000000001139","DOIUrl":null,"url":null,"abstract":"<p><p>While convex skin barriers have been used in patient care for decades, regulatory bodies and manufacturers have not established consistent parameters for measuring the most essential characteristics of a convex skin barrier. A transdisciplinary panel of manufacturers, engineers, marketing specialists and clinical subject matter experts from the United States was convened to address this gap. An initial consensus meeting was held to establish consensus around measurement parameters for 5 characteristics of convex skin barriers: depth, slope, flexibility, compressibility, and tension location. Consensus around 3 characteristics (depth, slope, and tension location) was achieved. In contrast, while multiple possible techniques for establishing measurement parameters for the remaining 2 characteristics (flexibility and compressibility) were discussed, final consensus for standardized measurement parameters was not achieved. The proceedings of this initial and novel approach to achieving consensus on measurement parameters for essential convexity characteristics lay the groundwork for development of international clinical practice standards on convex ostomy products. These standards aim to ensure predictable outcomes for persons with ostomies who use these products.</p>","PeriodicalId":49950,"journal":{"name":"Journal of Wound Ostomy and Continence Nursing","volume":"52 1","pages":"36-44"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of Convexity Characteristics: A Transdisciplinary Consensus Conference.\",\"authors\":\"Janice M Beitz, Jan Colwell, Dorothy Doughty, Laurie McNichol, Mikel Gray\",\"doi\":\"10.1097/WON.0000000000001139\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>While convex skin barriers have been used in patient care for decades, regulatory bodies and manufacturers have not established consistent parameters for measuring the most essential characteristics of a convex skin barrier. A transdisciplinary panel of manufacturers, engineers, marketing specialists and clinical subject matter experts from the United States was convened to address this gap. An initial consensus meeting was held to establish consensus around measurement parameters for 5 characteristics of convex skin barriers: depth, slope, flexibility, compressibility, and tension location. Consensus around 3 characteristics (depth, slope, and tension location) was achieved. In contrast, while multiple possible techniques for establishing measurement parameters for the remaining 2 characteristics (flexibility and compressibility) were discussed, final consensus for standardized measurement parameters was not achieved. The proceedings of this initial and novel approach to achieving consensus on measurement parameters for essential convexity characteristics lay the groundwork for development of international clinical practice standards on convex ostomy products. These standards aim to ensure predictable outcomes for persons with ostomies who use these products.</p>\",\"PeriodicalId\":49950,\"journal\":{\"name\":\"Journal of Wound Ostomy and Continence Nursing\",\"volume\":\"52 1\",\"pages\":\"36-44\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Wound Ostomy and Continence Nursing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/WON.0000000000001139\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/1/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"NURSING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Wound Ostomy and Continence Nursing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WON.0000000000001139","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0

摘要

虽然凸皮肤屏障已经在患者护理中使用了几十年,但监管机构和制造商尚未建立一致的参数来测量凸皮肤屏障的最基本特征。一个由来自美国的制造商、工程师、营销专家和临床主题专家组成的跨学科小组召开会议,以解决这一差距。召开初步共识会议,围绕凸蒙皮屏障的5个特征:深度、坡度、柔韧性、压缩性和张力位置的测量参数达成共识。在3个特征(深度、坡度和张力位置)上达成了共识。相比之下,虽然讨论了为其余2个特征(灵活性和可压缩性)建立测量参数的多种可能技术,但没有达成标准化测量参数的最终共识。这一初步和新颖的方法在基本凸性特征的测量参数上达成共识,为凸口造口产品的国际临床实践标准的发展奠定了基础。这些标准旨在确保使用这些产品的造口患者的可预测结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of Convexity Characteristics: A Transdisciplinary Consensus Conference.

While convex skin barriers have been used in patient care for decades, regulatory bodies and manufacturers have not established consistent parameters for measuring the most essential characteristics of a convex skin barrier. A transdisciplinary panel of manufacturers, engineers, marketing specialists and clinical subject matter experts from the United States was convened to address this gap. An initial consensus meeting was held to establish consensus around measurement parameters for 5 characteristics of convex skin barriers: depth, slope, flexibility, compressibility, and tension location. Consensus around 3 characteristics (depth, slope, and tension location) was achieved. In contrast, while multiple possible techniques for establishing measurement parameters for the remaining 2 characteristics (flexibility and compressibility) were discussed, final consensus for standardized measurement parameters was not achieved. The proceedings of this initial and novel approach to achieving consensus on measurement parameters for essential convexity characteristics lay the groundwork for development of international clinical practice standards on convex ostomy products. These standards aim to ensure predictable outcomes for persons with ostomies who use these products.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
34.60%
发文量
186
审稿时长
6-12 weeks
期刊介绍: ​​The Journal of Wound, Ostomy and Continence Nursing (JWOCN), the official journal of the Wound, Ostomy and Continence Nurses Society™ (WOCN®), is the premier publication for wound, ostomy and continence practice and research. The Journal’s mission is to publish current best evidence and original research to guide the delivery of expert health care. The WOCN Society is a professional nursing society which supports its members by promoting educational, clinical and research opportunities to advance the practice and guide the delivery of expert health care to individuals with wounds, ostomies and continence care needs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信