Relationship of maternal ophthalmic artery Doppler with uterine artery Doppler, hemodynamic indices and gestational age: prospective MATERA study.
Objectives: To examine the relationship of ophthalmic artery (OA) Doppler indices with uterine artery (UtA) Doppler indices, selected maternal hemodynamic parameters and gestational age, and to evaluate the intraobserver reproducibility of OA Doppler indices.
Methods: This was a prospective cohort study of women recruited between 11 + 0 and 23 + 6 weeks' gestation using a stratified and random sampling approach to ensure adequate distribution across the gestational-age range. OA pulsatility index (PI), first peak systolic velocity (PSV1), second peak systolic velocity (PSV2) and peak systolic velocity ratio (PSV ratio), calculated as PSV2/PSV1, were measured twice in each eye by the same observer. UtA-PI was also measured twice on each side by the same observer. Maternal hemodynamic assessment was undertaken using an ultrasonic cardiac output monitor (USCOM 1A). Pearson's and Spearman's rank correlation coefficients were used to assess the correlations between variables, and Bland-Altman plots were used to evaluate the intraobserver reproducibility of OA Doppler indices.
Results: Of 194 women invited to participate in the study, 169 were eligible for inclusion, of whom 16 were excluded following an obstetric ultrasound scan and a further three owing to inadequate or incomplete OA or UtA Doppler assessment, leaving 150 women in the final analysis. Log UtA-PI had a weak correlation with both OA-PI (r = -0.19 (95% CI, -0.34 to -0.03), P = 0.021) and OA-PSV ratio (r = 0.31 (95% CI, 0.15-0.45), P < 0.001). The correlation between gestational age and OA-PI was non-significant (r = 0.14 (95% CI, -0.03 to 0.29), P = 0.097), and that between gestational age and OA-PSV ratio was weak (r = -0.23 (95% CI, -0.38 to -0.07), P = 0.004), as opposed to the strong correlation between gestational age and UtA-PI (r = -0.68 (95% CI, -0.76 to -0.58), P < 0.001). No strong correlations were observed between OA-PI or OA-PSV ratio and maternal hemodynamic indices. The correlations were unaltered by adjustment for maternal age and body mass index. The intraobserver reproducibility of OA-PI and OA-PSV ratio in the same eye was high. The correlation between the right and left eyes was moderate for OA-PI (r = 0.63 (95% CI, 0.53-0.72), P < 0.001) and strong for OA-PSV ratio (r = 0.81 (95% CI, 0.75-0.86), P < 0.001).
期刊介绍:
Ultrasound in Obstetrics & Gynecology (UOG) is the official journal of the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) and is considered the foremost international peer-reviewed journal in the field. It publishes cutting-edge research that is highly relevant to clinical practice, which includes guidelines, expert commentaries, consensus statements, original articles, and systematic reviews. UOG is widely recognized and included in prominent abstract and indexing databases such as Index Medicus and Current Contents.