Heithem Jeddou, Stylianos Tzedakis, Mohamed Ali Chaouch, Laurent Sulpice, Michel Samson, Karim Boudjema
{"title":"常温机器肝灌注过程中生存能力评估:文献综述。","authors":"Heithem Jeddou, Stylianos Tzedakis, Mohamed Ali Chaouch, Laurent Sulpice, Michel Samson, Karim Boudjema","doi":"10.1111/liv.16244","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background and Objective</h3>\n \n <p>The discrepancy between donor organ availability and demand leads to a significant waiting-list dropout rate and mortality. Although quantitative tools such as the Donor Risk Index (DRI) help assess organ suitability, many potentially viable organs are still discarded due to the lack of universally accepted markers to predict post-transplant outcomes. Normothermic machine perfusion (NMP) offers a platform to assess viability before transplantation. Thus, livers considered unsuitable for transplantation based on the DRI can be evaluated and potentially transplanted. During NMP, various viability criteria have been proposed. These criteria are neither homogeneous nor consensual. In this review, we aimed to describe the viability criteria during NMP and evaluate their ability to predict hepatic graft function following transplantation. We conducted a PubMed search using the terms ‘liver transplantation’, ‘normothermic machine perfusion’ and ‘assessment’, including only English publications up to February 2024. Viability assessment during NMP includes multiple hepatocellular and cholangiocellular criteria. Lactate clearance and bile production are commonly used indicators, but their ability to predict post-transplant outcomes varies significantly. The predictive value of cholangiocellular criteria such as bile pH, bicarbonate and glucose levels remains under investigation. Novel markers, such as microRNAs and proteomic profiles, offer the potential to enhance graft evaluation accuracy and provide insights into the molecular mechanisms underlying liver viability. Combining perfusion parameters with biomarkers may improve the prediction of long-term graft survival. Future research should focus on standardising viability assessment protocols and exploring real-time biomarker evaluations, which could enhance transplantation outcomes and expand the donor pool.</p>\n </section>\n </div>","PeriodicalId":18101,"journal":{"name":"Liver International","volume":"45 2","pages":""},"PeriodicalIF":6.0000,"publicationDate":"2025-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11740183/pdf/","citationCount":"0","resultStr":"{\"title\":\"Viability Assessment During Normothermic Machine Liver Perfusion: A Literature Review\",\"authors\":\"Heithem Jeddou, Stylianos Tzedakis, Mohamed Ali Chaouch, Laurent Sulpice, Michel Samson, Karim Boudjema\",\"doi\":\"10.1111/liv.16244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background and Objective</h3>\\n \\n <p>The discrepancy between donor organ availability and demand leads to a significant waiting-list dropout rate and mortality. Although quantitative tools such as the Donor Risk Index (DRI) help assess organ suitability, many potentially viable organs are still discarded due to the lack of universally accepted markers to predict post-transplant outcomes. Normothermic machine perfusion (NMP) offers a platform to assess viability before transplantation. Thus, livers considered unsuitable for transplantation based on the DRI can be evaluated and potentially transplanted. During NMP, various viability criteria have been proposed. These criteria are neither homogeneous nor consensual. In this review, we aimed to describe the viability criteria during NMP and evaluate their ability to predict hepatic graft function following transplantation. We conducted a PubMed search using the terms ‘liver transplantation’, ‘normothermic machine perfusion’ and ‘assessment’, including only English publications up to February 2024. Viability assessment during NMP includes multiple hepatocellular and cholangiocellular criteria. Lactate clearance and bile production are commonly used indicators, but their ability to predict post-transplant outcomes varies significantly. The predictive value of cholangiocellular criteria such as bile pH, bicarbonate and glucose levels remains under investigation. Novel markers, such as microRNAs and proteomic profiles, offer the potential to enhance graft evaluation accuracy and provide insights into the molecular mechanisms underlying liver viability. Combining perfusion parameters with biomarkers may improve the prediction of long-term graft survival. Future research should focus on standardising viability assessment protocols and exploring real-time biomarker evaluations, which could enhance transplantation outcomes and expand the donor pool.</p>\\n </section>\\n </div>\",\"PeriodicalId\":18101,\"journal\":{\"name\":\"Liver International\",\"volume\":\"45 2\",\"pages\":\"\"},\"PeriodicalIF\":6.0000,\"publicationDate\":\"2025-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11740183/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Liver International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/liv.16244\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Liver International","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/liv.16244","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Viability Assessment During Normothermic Machine Liver Perfusion: A Literature Review
Background and Objective
The discrepancy between donor organ availability and demand leads to a significant waiting-list dropout rate and mortality. Although quantitative tools such as the Donor Risk Index (DRI) help assess organ suitability, many potentially viable organs are still discarded due to the lack of universally accepted markers to predict post-transplant outcomes. Normothermic machine perfusion (NMP) offers a platform to assess viability before transplantation. Thus, livers considered unsuitable for transplantation based on the DRI can be evaluated and potentially transplanted. During NMP, various viability criteria have been proposed. These criteria are neither homogeneous nor consensual. In this review, we aimed to describe the viability criteria during NMP and evaluate their ability to predict hepatic graft function following transplantation. We conducted a PubMed search using the terms ‘liver transplantation’, ‘normothermic machine perfusion’ and ‘assessment’, including only English publications up to February 2024. Viability assessment during NMP includes multiple hepatocellular and cholangiocellular criteria. Lactate clearance and bile production are commonly used indicators, but their ability to predict post-transplant outcomes varies significantly. The predictive value of cholangiocellular criteria such as bile pH, bicarbonate and glucose levels remains under investigation. Novel markers, such as microRNAs and proteomic profiles, offer the potential to enhance graft evaluation accuracy and provide insights into the molecular mechanisms underlying liver viability. Combining perfusion parameters with biomarkers may improve the prediction of long-term graft survival. Future research should focus on standardising viability assessment protocols and exploring real-time biomarker evaluations, which could enhance transplantation outcomes and expand the donor pool.
期刊介绍:
Liver International promotes all aspects of the science of hepatology from basic research to applied clinical studies. Providing an international forum for the publication of high-quality original research in hepatology, it is an essential resource for everyone working on normal and abnormal structure and function in the liver and its constituent cells, including clinicians and basic scientists involved in the multi-disciplinary field of hepatology. The journal welcomes articles from all fields of hepatology, which may be published as original articles, brief definitive reports, reviews, mini-reviews, images in hepatology and letters to the Editor.