{"title":"弧模拟角分辨率在单等心多靶点立体定向放射手术中的剂量学影响。","authors":"Perumal Murugan, Ravikumar Manickam, Tamilarasan Rajamanickam, Sivakumar Muthu, C Dinesan, Karthik Appunu, Abishake Murali","doi":"10.1007/s12194-024-00876-w","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.5 cm, 1 cm, and 2 cm at distances of 2.5 cm, 5 cm, and 7.5 cm from the isocentre using conformal arc and VMAT plans. Clinical validation involved 32 patients with 2-8 brain metastases, comparing plans recalculated at 1° and 2° resolutions. Dosimetric parameters included: D<sub>near-Min</sub>, D<sub>near-Max</sub>, D<sub>mean</sub>, D<sub>median</sub>, TV<sub>PIV</sub>, CI<sub>Paddick</sub>, GI, and Brain-GTV 12 Gy. For the 0.5 cm diameter target located at 7.5 cm distance from isocentre, phantom results showed TV<sub>PIV</sub>, D<sub>mean</sub>, and GI deviations of 7.91%, 1.8%, and 0.85 for single-conformal arcs, which decreased to 4.84%, 1.3%, and 0.77 with 4-conformal arcs, and 3.4%, 0.96%, and 0.5 for 4-arc VMAT. Deviations varied based on target size, isocentre distance, number of arcs, and arc type. Clinical results mirrored the phantom study, with maximum TV<sub>PIV</sub> and GI deviations of 2.76% and 0.65 for the smallest target (0.6 cm) located at 7.5 cm distance for four-arc VMAT. Other dosimetric parameters showed minimal variations (< 1%). Correlation analysis revealed strong associations between dosimetric differences, target size, and distance (r = 0.6-0.78 for small targets). MANOVA identified TV<sub>PIV</sub> as the only significant parameter (p = 0.01). A 1° angular resolution significantly improves dosimetric accuracy for small, distally located targets in SIMT SRS.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dosimetric impact of arc simulation angular resolution in single-isocentre multi-target stereotactic radiosurgery.\",\"authors\":\"Perumal Murugan, Ravikumar Manickam, Tamilarasan Rajamanickam, Sivakumar Muthu, C Dinesan, Karthik Appunu, Abishake Murali\",\"doi\":\"10.1007/s12194-024-00876-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.5 cm, 1 cm, and 2 cm at distances of 2.5 cm, 5 cm, and 7.5 cm from the isocentre using conformal arc and VMAT plans. Clinical validation involved 32 patients with 2-8 brain metastases, comparing plans recalculated at 1° and 2° resolutions. Dosimetric parameters included: D<sub>near-Min</sub>, D<sub>near-Max</sub>, D<sub>mean</sub>, D<sub>median</sub>, TV<sub>PIV</sub>, CI<sub>Paddick</sub>, GI, and Brain-GTV 12 Gy. For the 0.5 cm diameter target located at 7.5 cm distance from isocentre, phantom results showed TV<sub>PIV</sub>, D<sub>mean</sub>, and GI deviations of 7.91%, 1.8%, and 0.85 for single-conformal arcs, which decreased to 4.84%, 1.3%, and 0.77 with 4-conformal arcs, and 3.4%, 0.96%, and 0.5 for 4-arc VMAT. Deviations varied based on target size, isocentre distance, number of arcs, and arc type. Clinical results mirrored the phantom study, with maximum TV<sub>PIV</sub> and GI deviations of 2.76% and 0.65 for the smallest target (0.6 cm) located at 7.5 cm distance for four-arc VMAT. Other dosimetric parameters showed minimal variations (< 1%). Correlation analysis revealed strong associations between dosimetric differences, target size, and distance (r = 0.6-0.78 for small targets). MANOVA identified TV<sub>PIV</sub> as the only significant parameter (p = 0.01). A 1° angular resolution significantly improves dosimetric accuracy for small, distally located targets in SIMT SRS.</p>\",\"PeriodicalId\":46252,\"journal\":{\"name\":\"Radiological Physics and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiological Physics and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12194-024-00876-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-024-00876-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Dosimetric impact of arc simulation angular resolution in single-isocentre multi-target stereotactic radiosurgery.
This study evaluates the dosimetric impact of arc simulation angular resolution in VMAT-based Single Isocentre Multiple Target (SIMT) SRS, focusing on their dependence on target size, isocentre distance, number of arcs, and arc type. A phantom study analysed angular resolution (0.5°, 1°, 2°) effects on dosimetric accuracy for PTVs of 0.5 cm, 1 cm, and 2 cm at distances of 2.5 cm, 5 cm, and 7.5 cm from the isocentre using conformal arc and VMAT plans. Clinical validation involved 32 patients with 2-8 brain metastases, comparing plans recalculated at 1° and 2° resolutions. Dosimetric parameters included: Dnear-Min, Dnear-Max, Dmean, Dmedian, TVPIV, CIPaddick, GI, and Brain-GTV 12 Gy. For the 0.5 cm diameter target located at 7.5 cm distance from isocentre, phantom results showed TVPIV, Dmean, and GI deviations of 7.91%, 1.8%, and 0.85 for single-conformal arcs, which decreased to 4.84%, 1.3%, and 0.77 with 4-conformal arcs, and 3.4%, 0.96%, and 0.5 for 4-arc VMAT. Deviations varied based on target size, isocentre distance, number of arcs, and arc type. Clinical results mirrored the phantom study, with maximum TVPIV and GI deviations of 2.76% and 0.65 for the smallest target (0.6 cm) located at 7.5 cm distance for four-arc VMAT. Other dosimetric parameters showed minimal variations (< 1%). Correlation analysis revealed strong associations between dosimetric differences, target size, and distance (r = 0.6-0.78 for small targets). MANOVA identified TVPIV as the only significant parameter (p = 0.01). A 1° angular resolution significantly improves dosimetric accuracy for small, distally located targets in SIMT SRS.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.