以肱骨近端为例的基于形状匹配的骨折复位辅助概念-一项试点研究。

IF 2.3 3区 医学 Q3 ENGINEERING, BIOMEDICAL
Karen Mys, Luke Visscher, Sara Lindenmann, Torsten Pastor, Paolo Antonacci, Matthias Knobe, Martin Jaeger, Simon Lambert, Peter Varga
{"title":"以肱骨近端为例的基于形状匹配的骨折复位辅助概念-一项试点研究。","authors":"Karen Mys, Luke Visscher, Sara Lindenmann, Torsten Pastor, Paolo Antonacci, Matthias Knobe, Martin Jaeger, Simon Lambert, Peter Varga","doi":"10.1007/s11548-024-03318-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Optimizing fracture reduction quality is key to achieve successful osteosynthesis, especially for epimetaphyseal regions such as the proximal humerus (PH), but can be challenging, partly due to the lack of a clear endpoint. We aimed to develop the prototype for a novel intraoperative C-arm-based aid to facilitate true anatomical reduction of fractures of the PH.</p><p><strong>Methods: </strong>The proposed method designates the reduced endpoint position of fragments by superimposing the outer boundary of the premorbid bone shape on intraoperative C-arm images, taking the mirrored intact contralateral PH from the preoperative CT scan as a surrogate. The accuracy of the algorithm was tested on 60 synthetic C-arm images created from the preoperative CT images of 20 complex PH fracture cases (Dataset A) and on 12 real C-arm images of a prefractured human anatomical specimen (Dataset B). The predicted outer boundary shape was compared with the known exact solution by (1) a calculated matching error and (2) two experienced shoulder trauma surgeons.</p><p><strong>Results: </strong>A prediction accuracy of 88% (with 73% 'good') was achieved according to the calculation method and an 87% accuracy (68% 'good') by surgeon assessment in Dataset A. Accuracy was 100% by both assessments for Dataset B.</p><p><strong>Conclusion: </strong>By seamlessly integrating into the standard perioperative workflow and imaging, the intuitive shape-matching-based aid, once developed as a medical device, has the potential to optimize the accuracy of the reduction of PH fractures while reducing the number of X-rays and surgery time. Further studies are required to demonstrate the applicability and efficacy of this method in optimizing fracture reduction quality.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shape-matching-based fracture reduction aid concept exemplified on the proximal humerus-a pilot study.\",\"authors\":\"Karen Mys, Luke Visscher, Sara Lindenmann, Torsten Pastor, Paolo Antonacci, Matthias Knobe, Martin Jaeger, Simon Lambert, Peter Varga\",\"doi\":\"10.1007/s11548-024-03318-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Optimizing fracture reduction quality is key to achieve successful osteosynthesis, especially for epimetaphyseal regions such as the proximal humerus (PH), but can be challenging, partly due to the lack of a clear endpoint. We aimed to develop the prototype for a novel intraoperative C-arm-based aid to facilitate true anatomical reduction of fractures of the PH.</p><p><strong>Methods: </strong>The proposed method designates the reduced endpoint position of fragments by superimposing the outer boundary of the premorbid bone shape on intraoperative C-arm images, taking the mirrored intact contralateral PH from the preoperative CT scan as a surrogate. The accuracy of the algorithm was tested on 60 synthetic C-arm images created from the preoperative CT images of 20 complex PH fracture cases (Dataset A) and on 12 real C-arm images of a prefractured human anatomical specimen (Dataset B). The predicted outer boundary shape was compared with the known exact solution by (1) a calculated matching error and (2) two experienced shoulder trauma surgeons.</p><p><strong>Results: </strong>A prediction accuracy of 88% (with 73% 'good') was achieved according to the calculation method and an 87% accuracy (68% 'good') by surgeon assessment in Dataset A. Accuracy was 100% by both assessments for Dataset B.</p><p><strong>Conclusion: </strong>By seamlessly integrating into the standard perioperative workflow and imaging, the intuitive shape-matching-based aid, once developed as a medical device, has the potential to optimize the accuracy of the reduction of PH fractures while reducing the number of X-rays and surgery time. Further studies are required to demonstrate the applicability and efficacy of this method in optimizing fracture reduction quality.</p>\",\"PeriodicalId\":51251,\"journal\":{\"name\":\"International Journal of Computer Assisted Radiology and Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-01-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computer Assisted Radiology and Surgery\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s11548-024-03318-5\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03318-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:优化骨折复位质量是成功进行骨合成的关键,尤其是对于肱骨近端(PH)等骺区,但这可能具有挑战性,部分原因是缺乏明确的终点。我们旨在开发一种基于 C 臂的新型术中辅助工具原型,以促进 PH 骨折的真正解剖复位:方法:所提出的方法通过在术中 C 臂图像上叠加原骨形状的外边界来指定骨折片的缩小端点位置,并以术前 CT 扫描中的完整对侧 PH 镜像作为替代物。该算法的准确性在 20 个复杂 PH 骨折病例(数据集 A)的术前 CT 图像制作的 60 张合成 C 臂图像和 12 张骨折前人体解剖标本的真实 C 臂图像(数据集 B)上进行了测试。通过(1)计算匹配误差和(2)两名经验丰富的肩部创伤外科医生,将预测的外部边界形状与已知的精确解进行比较:结果:根据计算方法,数据集 A 的预测准确率为 88%(73% 为 "良好"),根据外科医生的评估,准确率为 87%(68% 为 "良好"):通过无缝集成到标准围手术期工作流程和成像中,这种基于形状匹配的直观辅助工具一旦作为医疗设备开发出来,就有可能优化 PH 骨折复位的准确性,同时减少 X 射线的数量和手术时间。要证明这种方法在优化骨折复位质量方面的适用性和有效性,还需要进一步的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Shape-matching-based fracture reduction aid concept exemplified on the proximal humerus-a pilot study.

Purpose: Optimizing fracture reduction quality is key to achieve successful osteosynthesis, especially for epimetaphyseal regions such as the proximal humerus (PH), but can be challenging, partly due to the lack of a clear endpoint. We aimed to develop the prototype for a novel intraoperative C-arm-based aid to facilitate true anatomical reduction of fractures of the PH.

Methods: The proposed method designates the reduced endpoint position of fragments by superimposing the outer boundary of the premorbid bone shape on intraoperative C-arm images, taking the mirrored intact contralateral PH from the preoperative CT scan as a surrogate. The accuracy of the algorithm was tested on 60 synthetic C-arm images created from the preoperative CT images of 20 complex PH fracture cases (Dataset A) and on 12 real C-arm images of a prefractured human anatomical specimen (Dataset B). The predicted outer boundary shape was compared with the known exact solution by (1) a calculated matching error and (2) two experienced shoulder trauma surgeons.

Results: A prediction accuracy of 88% (with 73% 'good') was achieved according to the calculation method and an 87% accuracy (68% 'good') by surgeon assessment in Dataset A. Accuracy was 100% by both assessments for Dataset B.

Conclusion: By seamlessly integrating into the standard perioperative workflow and imaging, the intuitive shape-matching-based aid, once developed as a medical device, has the potential to optimize the accuracy of the reduction of PH fractures while reducing the number of X-rays and surgery time. Further studies are required to demonstrate the applicability and efficacy of this method in optimizing fracture reduction quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信