A Scott Emmert, Tiffany Ruan, Michael G Sherenian, Amal H Assa'ad, Nichole Leitsinger, Lindsay Schultz, Viral V Jain, Peter F Sturm, Alvin C Jones
{"title":"小儿脊柱外科金属过敏的患病率。","authors":"A Scott Emmert, Tiffany Ruan, Michael G Sherenian, Amal H Assa'ad, Nichole Leitsinger, Lindsay Schultz, Viral V Jain, Peter F Sturm, Alvin C Jones","doi":"10.1007/s43390-024-01030-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Delayed metal hypersensitivity reactions can cause complications in spine surgery. Currently, there is no information on the prevalence of metal hypersensitivity in pediatric patients undergoing spine surgery. The objective of this study is to determine the prevalence of metal hypersensitivity in pediatric patients undergoing spinal instrumentation.</p><p><strong>Methods: </strong>Retrospective chart review of patients who underwent spinal instrumentation with or without fusion at a single institution, from January 1, 2014, to December 31, 2020, was performed. Patients were pre-screened for history of allergic diseases, including previous reaction to metals, prior to surgery. Patch metal allergy testing (PMAT) for metal hypersensitivity was also performed.</p><p><strong>Results: </strong>Of the 796 pediatric patients who underwent spinal instrumentation procedures from 2014 to 2020, 118 (15%) screened positive for metal hypersensitivity. However, the number of patients with documented evidence of metal hypersensitivity diminished to 26 (3%) after PMAT verification. Nickel hypersensitivity was most prevalent, with 20 patients (16.9% of positive screening; 2.5% of all instrumented patients) demonstrating positive skin patch tests. The other most prevalent metal hypersensitivities included cobalt in 9 patients (7.6%; 1.1%), manganese in 3 patients (2.5%; 0.4%), and copper in 1 patient (0.8%; 0.1%). with a number needed to treat (NNT) of 5.</p><p><strong>Conclusions: </strong>This study suggests that routine pre-operative PMAT is not necessary in all pediatric spine patients yet should be considered if patients report a history of prior metal hypersensitivity reactions.</p>","PeriodicalId":21796,"journal":{"name":"Spine deformity","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prevalence of metal hypersensitivity in pediatric spine surgery.\",\"authors\":\"A Scott Emmert, Tiffany Ruan, Michael G Sherenian, Amal H Assa'ad, Nichole Leitsinger, Lindsay Schultz, Viral V Jain, Peter F Sturm, Alvin C Jones\",\"doi\":\"10.1007/s43390-024-01030-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Delayed metal hypersensitivity reactions can cause complications in spine surgery. Currently, there is no information on the prevalence of metal hypersensitivity in pediatric patients undergoing spine surgery. The objective of this study is to determine the prevalence of metal hypersensitivity in pediatric patients undergoing spinal instrumentation.</p><p><strong>Methods: </strong>Retrospective chart review of patients who underwent spinal instrumentation with or without fusion at a single institution, from January 1, 2014, to December 31, 2020, was performed. Patients were pre-screened for history of allergic diseases, including previous reaction to metals, prior to surgery. Patch metal allergy testing (PMAT) for metal hypersensitivity was also performed.</p><p><strong>Results: </strong>Of the 796 pediatric patients who underwent spinal instrumentation procedures from 2014 to 2020, 118 (15%) screened positive for metal hypersensitivity. However, the number of patients with documented evidence of metal hypersensitivity diminished to 26 (3%) after PMAT verification. Nickel hypersensitivity was most prevalent, with 20 patients (16.9% of positive screening; 2.5% of all instrumented patients) demonstrating positive skin patch tests. The other most prevalent metal hypersensitivities included cobalt in 9 patients (7.6%; 1.1%), manganese in 3 patients (2.5%; 0.4%), and copper in 1 patient (0.8%; 0.1%). with a number needed to treat (NNT) of 5.</p><p><strong>Conclusions: </strong>This study suggests that routine pre-operative PMAT is not necessary in all pediatric spine patients yet should be considered if patients report a history of prior metal hypersensitivity reactions.</p>\",\"PeriodicalId\":21796,\"journal\":{\"name\":\"Spine deformity\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2025-01-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spine deformity\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s43390-024-01030-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spine deformity","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s43390-024-01030-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Prevalence of metal hypersensitivity in pediatric spine surgery.
Purpose: Delayed metal hypersensitivity reactions can cause complications in spine surgery. Currently, there is no information on the prevalence of metal hypersensitivity in pediatric patients undergoing spine surgery. The objective of this study is to determine the prevalence of metal hypersensitivity in pediatric patients undergoing spinal instrumentation.
Methods: Retrospective chart review of patients who underwent spinal instrumentation with or without fusion at a single institution, from January 1, 2014, to December 31, 2020, was performed. Patients were pre-screened for history of allergic diseases, including previous reaction to metals, prior to surgery. Patch metal allergy testing (PMAT) for metal hypersensitivity was also performed.
Results: Of the 796 pediatric patients who underwent spinal instrumentation procedures from 2014 to 2020, 118 (15%) screened positive for metal hypersensitivity. However, the number of patients with documented evidence of metal hypersensitivity diminished to 26 (3%) after PMAT verification. Nickel hypersensitivity was most prevalent, with 20 patients (16.9% of positive screening; 2.5% of all instrumented patients) demonstrating positive skin patch tests. The other most prevalent metal hypersensitivities included cobalt in 9 patients (7.6%; 1.1%), manganese in 3 patients (2.5%; 0.4%), and copper in 1 patient (0.8%; 0.1%). with a number needed to treat (NNT) of 5.
Conclusions: This study suggests that routine pre-operative PMAT is not necessary in all pediatric spine patients yet should be considered if patients report a history of prior metal hypersensitivity reactions.
期刊介绍:
Spine Deformity the official journal of the?Scoliosis Research Society is a peer-refereed publication to disseminate knowledge on basic science and clinical research into the?etiology?biomechanics?treatment?methods and outcomes of all types of?spinal deformities. The international members of the Editorial Board provide a worldwide perspective for the journal's area of interest.The?journal?will enhance the mission of the Society which is to foster the optimal care of all patients with?spine?deformities worldwide. Articles published in?Spine Deformity?are Medline indexed in PubMed.? The journal publishes original articles in the form of clinical and basic research. Spine Deformity will only publish studies that have institutional review board (IRB) or similar ethics committee approval for human and animal studies and have strictly observed these guidelines. The minimum follow-up period for follow-up clinical studies is 24 months.