{"title":"利用环形线技术释放楔形对接按钮,用标准取物导管取出Aveir无铅起搏器。","authors":"Kensuke Yano, Masaya Shinohara, Hideto Sasaki, Takuto Suzuki, Hosei Kikushima, Ryo Wada, Shintaro Yao, Hideki Koike, Tadashi Fujino, Takanori Ikeda","doi":"10.1111/jce.16556","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>The docking button of the Aveir leadless pacemaker (LP) is occasionally difficult to access due to its inappropriate position in the right ventricle (RV).</p>\n </section>\n \n <section>\n \n <h3> Methods and Results</h3>\n \n <p>We report a case where the Aveir LP was successfully retrieved by releasing the wedged docking button in the inferior wall of the RV using a loop wire technique.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The loop wire technique may be useful to change the position of the Aveir LP. This may be helpful to retrieve the Aveir LP even in a case where the docking button is wedged in the inferior wall of the RV.</p>\n </section>\n </div>","PeriodicalId":15178,"journal":{"name":"Journal of Cardiovascular Electrophysiology","volume":"36 3","pages":"700-704"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Retrieval of an Aveir Leadless Pacemaker With a Standard Retrieval Catheter by Releasing the Wedged Docking Button Using a Loop Wire Technique\",\"authors\":\"Kensuke Yano, Masaya Shinohara, Hideto Sasaki, Takuto Suzuki, Hosei Kikushima, Ryo Wada, Shintaro Yao, Hideki Koike, Tadashi Fujino, Takanori Ikeda\",\"doi\":\"10.1111/jce.16556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>The docking button of the Aveir leadless pacemaker (LP) is occasionally difficult to access due to its inappropriate position in the right ventricle (RV).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods and Results</h3>\\n \\n <p>We report a case where the Aveir LP was successfully retrieved by releasing the wedged docking button in the inferior wall of the RV using a loop wire technique.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>The loop wire technique may be useful to change the position of the Aveir LP. This may be helpful to retrieve the Aveir LP even in a case where the docking button is wedged in the inferior wall of the RV.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15178,\"journal\":{\"name\":\"Journal of Cardiovascular Electrophysiology\",\"volume\":\"36 3\",\"pages\":\"700-704\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-01-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jce.16556\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jce.16556","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Retrieval of an Aveir Leadless Pacemaker With a Standard Retrieval Catheter by Releasing the Wedged Docking Button Using a Loop Wire Technique
Introduction
The docking button of the Aveir leadless pacemaker (LP) is occasionally difficult to access due to its inappropriate position in the right ventricle (RV).
Methods and Results
We report a case where the Aveir LP was successfully retrieved by releasing the wedged docking button in the inferior wall of the RV using a loop wire technique.
Conclusion
The loop wire technique may be useful to change the position of the Aveir LP. This may be helpful to retrieve the Aveir LP even in a case where the docking button is wedged in the inferior wall of the RV.
期刊介绍:
Journal of Cardiovascular Electrophysiology (JCE) keeps its readership well informed of the latest developments in the study and management of arrhythmic disorders. Edited by Bradley P. Knight, M.D., and a distinguished international editorial board, JCE is the leading journal devoted to the study of the electrophysiology of the heart.