多内标在线定标在ICP-MS测定碘中的应用。

IF 1.9 3区 化学 Q3 BIOCHEMICAL RESEARCH METHODS
Long-Hua Zhou, Xing-Chen Lin, Li-Li Suo, Li-Fang Ma, Gui-Xiang Hu, Xiang Xia, Ming Li, Wei-Hua Huang, Yong-Jiu Jin
{"title":"多内标在线定标在ICP-MS测定碘中的应用。","authors":"Long-Hua Zhou,&nbsp;Xing-Chen Lin,&nbsp;Li-Li Suo,&nbsp;Li-Fang Ma,&nbsp;Gui-Xiang Hu,&nbsp;Xiang Xia,&nbsp;Ming Li,&nbsp;Wei-Hua Huang,&nbsp;Yong-Jiu Jin","doi":"10.1002/jms.5109","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>This study presents a comprehensive evaluation of the application of online multi-internal standard calibration (M.ISC) in determining iodine concentrations through inductively coupled plasma mass spectrometry (ICP-MS). Notably, M.ISC streamlines the calibration process by requiring only a single standard solution, thereby enhancing sample throughput and minimizing liquid waste. In addition, unlike conventional internal standard (IS) methods, M.ISC omits the need for time-consuming species identification by utilizing multiple IS species simultaneously to minimize signal biases. The effectiveness of M.ISC was validated through the analysis of six standard reference samples, with the results of LOD and LOQ also being calculated by the error propagation approach. The traditional chemical analytical methods (TCAM), external standard calibration (EC) and single IS methods were also evaluated as comparative purpose. Nonetheless, M.ISC emerges as a straightforward matrix-correction strategy, offering a simple and efficient alternative to traditional calibration methods for iodine detection by ICP-MS.</p>\n </div>","PeriodicalId":16178,"journal":{"name":"Journal of Mass Spectrometry","volume":"60 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of Online Multi-Internal Standard Calibration for Determination of Iodine by ICP-MS\",\"authors\":\"Long-Hua Zhou,&nbsp;Xing-Chen Lin,&nbsp;Li-Li Suo,&nbsp;Li-Fang Ma,&nbsp;Gui-Xiang Hu,&nbsp;Xiang Xia,&nbsp;Ming Li,&nbsp;Wei-Hua Huang,&nbsp;Yong-Jiu Jin\",\"doi\":\"10.1002/jms.5109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>This study presents a comprehensive evaluation of the application of online multi-internal standard calibration (M.ISC) in determining iodine concentrations through inductively coupled plasma mass spectrometry (ICP-MS). Notably, M.ISC streamlines the calibration process by requiring only a single standard solution, thereby enhancing sample throughput and minimizing liquid waste. In addition, unlike conventional internal standard (IS) methods, M.ISC omits the need for time-consuming species identification by utilizing multiple IS species simultaneously to minimize signal biases. The effectiveness of M.ISC was validated through the analysis of six standard reference samples, with the results of LOD and LOQ also being calculated by the error propagation approach. The traditional chemical analytical methods (TCAM), external standard calibration (EC) and single IS methods were also evaluated as comparative purpose. Nonetheless, M.ISC emerges as a straightforward matrix-correction strategy, offering a simple and efficient alternative to traditional calibration methods for iodine detection by ICP-MS.</p>\\n </div>\",\"PeriodicalId\":16178,\"journal\":{\"name\":\"Journal of Mass Spectrometry\",\"volume\":\"60 1\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jms.5109\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jms.5109","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

本研究对在线多内标校准(m.s isc)在电感耦合等离子体质谱(ICP-MS)测定碘浓度中的应用进行了综合评价。值得注意的是,m.s isc简化了校准过程,只需要一个标准溶液,从而提高了样品吞吐量,最大限度地减少了液体浪费。此外,与传统的内部标准(IS)方法不同,M.ISC通过同时利用多个IS物种来减少信号偏差,从而省去了耗时的物种识别的需要。通过对6个标准参比样品的分析,验证了m.s isc的有效性,并通过误差传播法计算了LOD和LOQ的结果。并对传统的化学分析方法(TCAM)、外部标准校准(EC)和单一IS方法进行了比较。尽管如此,M.ISC作为一种直接的矩阵校正策略出现,为ICP-MS检测碘提供了一种简单有效的替代传统校准方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of Online Multi-Internal Standard Calibration for Determination of Iodine by ICP-MS

This study presents a comprehensive evaluation of the application of online multi-internal standard calibration (M.ISC) in determining iodine concentrations through inductively coupled plasma mass spectrometry (ICP-MS). Notably, M.ISC streamlines the calibration process by requiring only a single standard solution, thereby enhancing sample throughput and minimizing liquid waste. In addition, unlike conventional internal standard (IS) methods, M.ISC omits the need for time-consuming species identification by utilizing multiple IS species simultaneously to minimize signal biases. The effectiveness of M.ISC was validated through the analysis of six standard reference samples, with the results of LOD and LOQ also being calculated by the error propagation approach. The traditional chemical analytical methods (TCAM), external standard calibration (EC) and single IS methods were also evaluated as comparative purpose. Nonetheless, M.ISC emerges as a straightforward matrix-correction strategy, offering a simple and efficient alternative to traditional calibration methods for iodine detection by ICP-MS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry
Journal of Mass Spectrometry 化学-光谱学
CiteScore
5.10
自引率
0.00%
发文量
84
审稿时长
1.5 months
期刊介绍: The Journal of Mass Spectrometry publishes papers on a broad range of topics of interest to scientists working in both fundamental and applied areas involving the study of gaseous ions. The aim of JMS is to serve the scientific community with information provided and arranged to help senior investigators to better stay abreast of new discoveries and studies in their own field, to make them aware of events and developments in associated fields, and to provide students and newcomers the basic tools with which to learn fundamental and applied aspects of mass spectrometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信