Thomas W Martens, Holly J Willis, Richard M Bergenstal, Davida F Kruger, Esra Karslioglu-French, Devin W Steenkamp
{"title":"一项使用连续血糖监测指导未使用胰岛素的2型糖尿病患者的食物选择和糖尿病自我护理的随机对照试验","authors":"Thomas W Martens, Holly J Willis, Richard M Bergenstal, Davida F Kruger, Esra Karslioglu-French, Devin W Steenkamp","doi":"10.1089/dia.2024.0579","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Objective:</i></b> Continuous glucose monitoring (CGM) is an effective tool for individuals with type 2 diabetes (T2D) on insulin. This study evaluated the effect of using CGM to reduce hyperglycemia, by focusing on food and lifestyle choices, in people with T2D not taking insulin. <b><i>Methods:</i></b> A 6-month randomized, prospective four-center study was conducted. The primary end point was a within-group reduction in time above range >180 mg/dL (TAR180) at 3 months. Participants were asked not to make diabetes medication changes in the first 3 months. Seventy-two adults not on insulin or sulfonylurea therapy, with glycated hemoglobin (HbA1c) 7.5%-12%, were randomized to use CGM alone (<i>n</i> = 31) or CGM plus a food logging app (<i>n</i> = 41) to aid diabetes management. Participants attended guided education visits. Differences in CGM metrics, HbA1c, and body weight were compared. <b><i>Results:</i></b> The CGM alone group decreased TAR180 from 55% at baseline to 27% at 3 months (<i>P</i> < 0.001) and 21% at 6 months (<i>P</i> < 0.001); the CGM plus food logging app group decreased TAR180 from 53% at baseline to 30% at both 3 and 6 months (<i>P</i> < 0.001 for both). For all participants, time in range (70-180 mg/dL) increased from 46% at baseline to 71% at 3 months (<i>P</i> < 0.001) and to 72% at 6 months (<i>P</i> < 0.001). HbA1c and weight were reduced by 1.3% (<i>P</i> < 0.001) and 7 pounds (lbs.) (<i>P</i> < 0.001) for all participants at 6 months. <b><i>Conclusion:</i></b> People with T2D not taking insulin showed large, clinically significant improvements in CGM metrics and HbA1c when using either CGM alone or with a food logging app. This occurred with a near absence of medication changes in the first 3 months and were therefore likely due to changes in food and/or lifestyle choices.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Randomized Controlled Trial Using Continuous Glucose Monitoring to Guide Food Choices and Diabetes Self-Care in People with Type 2 Diabetes not Taking Insulin.\",\"authors\":\"Thomas W Martens, Holly J Willis, Richard M Bergenstal, Davida F Kruger, Esra Karslioglu-French, Devin W Steenkamp\",\"doi\":\"10.1089/dia.2024.0579\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Objective:</i></b> Continuous glucose monitoring (CGM) is an effective tool for individuals with type 2 diabetes (T2D) on insulin. This study evaluated the effect of using CGM to reduce hyperglycemia, by focusing on food and lifestyle choices, in people with T2D not taking insulin. <b><i>Methods:</i></b> A 6-month randomized, prospective four-center study was conducted. The primary end point was a within-group reduction in time above range >180 mg/dL (TAR180) at 3 months. Participants were asked not to make diabetes medication changes in the first 3 months. Seventy-two adults not on insulin or sulfonylurea therapy, with glycated hemoglobin (HbA1c) 7.5%-12%, were randomized to use CGM alone (<i>n</i> = 31) or CGM plus a food logging app (<i>n</i> = 41) to aid diabetes management. Participants attended guided education visits. Differences in CGM metrics, HbA1c, and body weight were compared. <b><i>Results:</i></b> The CGM alone group decreased TAR180 from 55% at baseline to 27% at 3 months (<i>P</i> < 0.001) and 21% at 6 months (<i>P</i> < 0.001); the CGM plus food logging app group decreased TAR180 from 53% at baseline to 30% at both 3 and 6 months (<i>P</i> < 0.001 for both). For all participants, time in range (70-180 mg/dL) increased from 46% at baseline to 71% at 3 months (<i>P</i> < 0.001) and to 72% at 6 months (<i>P</i> < 0.001). HbA1c and weight were reduced by 1.3% (<i>P</i> < 0.001) and 7 pounds (lbs.) (<i>P</i> < 0.001) for all participants at 6 months. <b><i>Conclusion:</i></b> People with T2D not taking insulin showed large, clinically significant improvements in CGM metrics and HbA1c when using either CGM alone or with a food logging app. This occurred with a near absence of medication changes in the first 3 months and were therefore likely due to changes in food and/or lifestyle choices.</p>\",\"PeriodicalId\":11159,\"journal\":{\"name\":\"Diabetes technology & therapeutics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2025-01-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes technology & therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/dia.2024.0579\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2024.0579","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
A Randomized Controlled Trial Using Continuous Glucose Monitoring to Guide Food Choices and Diabetes Self-Care in People with Type 2 Diabetes not Taking Insulin.
Objective: Continuous glucose monitoring (CGM) is an effective tool for individuals with type 2 diabetes (T2D) on insulin. This study evaluated the effect of using CGM to reduce hyperglycemia, by focusing on food and lifestyle choices, in people with T2D not taking insulin. Methods: A 6-month randomized, prospective four-center study was conducted. The primary end point was a within-group reduction in time above range >180 mg/dL (TAR180) at 3 months. Participants were asked not to make diabetes medication changes in the first 3 months. Seventy-two adults not on insulin or sulfonylurea therapy, with glycated hemoglobin (HbA1c) 7.5%-12%, were randomized to use CGM alone (n = 31) or CGM plus a food logging app (n = 41) to aid diabetes management. Participants attended guided education visits. Differences in CGM metrics, HbA1c, and body weight were compared. Results: The CGM alone group decreased TAR180 from 55% at baseline to 27% at 3 months (P < 0.001) and 21% at 6 months (P < 0.001); the CGM plus food logging app group decreased TAR180 from 53% at baseline to 30% at both 3 and 6 months (P < 0.001 for both). For all participants, time in range (70-180 mg/dL) increased from 46% at baseline to 71% at 3 months (P < 0.001) and to 72% at 6 months (P < 0.001). HbA1c and weight were reduced by 1.3% (P < 0.001) and 7 pounds (lbs.) (P < 0.001) for all participants at 6 months. Conclusion: People with T2D not taking insulin showed large, clinically significant improvements in CGM metrics and HbA1c when using either CGM alone or with a food logging app. This occurred with a near absence of medication changes in the first 3 months and were therefore likely due to changes in food and/or lifestyle choices.
期刊介绍:
Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.