Xinsong Du, Amanda Dobrowolski, Mathias Brochhausen, Timothy J Garrett, William R Hogan, Dominick J Lemas
{"title":"Nextflow4MS-DIAL:可重复的液相色谱-质谱代谢组学数据处理Nextflow-Based工作流。","authors":"Xinsong Du, Amanda Dobrowolski, Mathias Brochhausen, Timothy J Garrett, William R Hogan, Dominick J Lemas","doi":"10.1021/jasms.4c00364","DOIUrl":null,"url":null,"abstract":"<p><p>Reproducibility in untargeted metabolomics data processing remains a significant challenge due to software limitations and the complex series of steps required. To address these issues, we developed Nextflow4MS-DIAL, a reproducible workflow for liquid chromatography-mass spectrometry (LC-MS) metabolomics data processing, validated with publicly available data from MetaboLights (MTBLS733). Nextflow4MS-DIAL automates LC-MS data processing to minimize human errors from manual data handling. The workflow supports software containerization, ensuring computational reproducibility and enabling collaborative research. Nextflow4MS-DIAL is compatible with any Unix-like system and supports multiple job schedulers, offering flexibility and ease of use. The Nextflow4MS-DIAL workflow is available under the permissive MIT license: https://github.com/Nextflow4Metabolomics/nextflow4ms-dial.</p>","PeriodicalId":672,"journal":{"name":"Journal of the American Society for Mass Spectrometry","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2025-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nextflow4MS-DIAL: A Reproducible Nextflow-Based Workflow for Liquid Chromatography-Mass Spectrometry Metabolomics Data Processing.\",\"authors\":\"Xinsong Du, Amanda Dobrowolski, Mathias Brochhausen, Timothy J Garrett, William R Hogan, Dominick J Lemas\",\"doi\":\"10.1021/jasms.4c00364\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Reproducibility in untargeted metabolomics data processing remains a significant challenge due to software limitations and the complex series of steps required. To address these issues, we developed Nextflow4MS-DIAL, a reproducible workflow for liquid chromatography-mass spectrometry (LC-MS) metabolomics data processing, validated with publicly available data from MetaboLights (MTBLS733). Nextflow4MS-DIAL automates LC-MS data processing to minimize human errors from manual data handling. The workflow supports software containerization, ensuring computational reproducibility and enabling collaborative research. Nextflow4MS-DIAL is compatible with any Unix-like system and supports multiple job schedulers, offering flexibility and ease of use. The Nextflow4MS-DIAL workflow is available under the permissive MIT license: https://github.com/Nextflow4Metabolomics/nextflow4ms-dial.</p>\",\"PeriodicalId\":672,\"journal\":{\"name\":\"Journal of the American Society for Mass Spectrometry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2025-01-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Society for Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/jasms.4c00364\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society for Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/jasms.4c00364","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Nextflow4MS-DIAL: A Reproducible Nextflow-Based Workflow for Liquid Chromatography-Mass Spectrometry Metabolomics Data Processing.
Reproducibility in untargeted metabolomics data processing remains a significant challenge due to software limitations and the complex series of steps required. To address these issues, we developed Nextflow4MS-DIAL, a reproducible workflow for liquid chromatography-mass spectrometry (LC-MS) metabolomics data processing, validated with publicly available data from MetaboLights (MTBLS733). Nextflow4MS-DIAL automates LC-MS data processing to minimize human errors from manual data handling. The workflow supports software containerization, ensuring computational reproducibility and enabling collaborative research. Nextflow4MS-DIAL is compatible with any Unix-like system and supports multiple job schedulers, offering flexibility and ease of use. The Nextflow4MS-DIAL workflow is available under the permissive MIT license: https://github.com/Nextflow4Metabolomics/nextflow4ms-dial.
期刊介绍:
The Journal of the American Society for Mass Spectrometry presents research papers covering all aspects of mass spectrometry, incorporating coverage of fields of scientific inquiry in which mass spectrometry can play a role.
Comprehensive in scope, the journal publishes papers on both fundamentals and applications of mass spectrometry. Fundamental subjects include instrumentation principles, design, and demonstration, structures and chemical properties of gas-phase ions, studies of thermodynamic properties, ion spectroscopy, chemical kinetics, mechanisms of ionization, theories of ion fragmentation, cluster ions, and potential energy surfaces. In addition to full papers, the journal offers Communications, Application Notes, and Accounts and Perspectives