Yangyang Yuan, Jionghui Liu, Chenyun Dai, Xiao Liu, Bo Hu, Jiahao Fan
{"title":"通过不同的表面肌电信号测量探索与手势相关的模式特定组件。","authors":"Yangyang Yuan, Jionghui Liu, Chenyun Dai, Xiao Liu, Bo Hu, Jiahao Fan","doi":"10.1186/s12984-024-01526-3","DOIUrl":null,"url":null,"abstract":"<p><p>For surface electromyography (sEMG) based human-machine interaction systems, accurately recognizing the users' gesture intent is crucial. However, due to the existence of subject-specific components in sEMG signals, subject-specific models may deteriorate when applied to new users. In this study, we hypothesize that in addition to subject-specific components, sEMG signals also contain pattern-specific components, which is independent of individuals and solely related to gesture patterns. Based on this hypothesis, we disentangled these two components from sEMG signals with an auto-encoder and applied the pattern-specific components to establish a general gesture recognition model in cross-subject scenarios. Furthermore, we compared the characteristics of the pattern-specific information contained in three categories of EMG measures: signal waveform, time-domain features, and frequency-domain features. Our hypothesis was validated on an open source database. Ultimately, the combination of time- and frequency-domain features achieved the best performance in gesture classification tasks, with a maximum accuracy of 84.3%. For individual feature, frequency-domain features performed the best and were proved most suitable for separating the two components. Additionally, we intuitively visualized the heatmaps of pattern-specific components based on the topological position of electrode arrays and explored their physiological interpretability by examining the correspondence between the heatmaps and muscle activation areas.</p>","PeriodicalId":16384,"journal":{"name":"Journal of NeuroEngineering and Rehabilitation","volume":"21 1","pages":"233"},"PeriodicalIF":5.2000,"publicationDate":"2024-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11689514/pdf/","citationCount":"0","resultStr":"{\"title\":\"Exploring pattern-specific components associated with hand gestures through different sEMG measures.\",\"authors\":\"Yangyang Yuan, Jionghui Liu, Chenyun Dai, Xiao Liu, Bo Hu, Jiahao Fan\",\"doi\":\"10.1186/s12984-024-01526-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>For surface electromyography (sEMG) based human-machine interaction systems, accurately recognizing the users' gesture intent is crucial. However, due to the existence of subject-specific components in sEMG signals, subject-specific models may deteriorate when applied to new users. In this study, we hypothesize that in addition to subject-specific components, sEMG signals also contain pattern-specific components, which is independent of individuals and solely related to gesture patterns. Based on this hypothesis, we disentangled these two components from sEMG signals with an auto-encoder and applied the pattern-specific components to establish a general gesture recognition model in cross-subject scenarios. Furthermore, we compared the characteristics of the pattern-specific information contained in three categories of EMG measures: signal waveform, time-domain features, and frequency-domain features. Our hypothesis was validated on an open source database. Ultimately, the combination of time- and frequency-domain features achieved the best performance in gesture classification tasks, with a maximum accuracy of 84.3%. For individual feature, frequency-domain features performed the best and were proved most suitable for separating the two components. Additionally, we intuitively visualized the heatmaps of pattern-specific components based on the topological position of electrode arrays and explored their physiological interpretability by examining the correspondence between the heatmaps and muscle activation areas.</p>\",\"PeriodicalId\":16384,\"journal\":{\"name\":\"Journal of NeuroEngineering and Rehabilitation\",\"volume\":\"21 1\",\"pages\":\"233\"},\"PeriodicalIF\":5.2000,\"publicationDate\":\"2024-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11689514/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of NeuroEngineering and Rehabilitation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1186/s12984-024-01526-3\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroEngineering and Rehabilitation","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s12984-024-01526-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Exploring pattern-specific components associated with hand gestures through different sEMG measures.
For surface electromyography (sEMG) based human-machine interaction systems, accurately recognizing the users' gesture intent is crucial. However, due to the existence of subject-specific components in sEMG signals, subject-specific models may deteriorate when applied to new users. In this study, we hypothesize that in addition to subject-specific components, sEMG signals also contain pattern-specific components, which is independent of individuals and solely related to gesture patterns. Based on this hypothesis, we disentangled these two components from sEMG signals with an auto-encoder and applied the pattern-specific components to establish a general gesture recognition model in cross-subject scenarios. Furthermore, we compared the characteristics of the pattern-specific information contained in three categories of EMG measures: signal waveform, time-domain features, and frequency-domain features. Our hypothesis was validated on an open source database. Ultimately, the combination of time- and frequency-domain features achieved the best performance in gesture classification tasks, with a maximum accuracy of 84.3%. For individual feature, frequency-domain features performed the best and were proved most suitable for separating the two components. Additionally, we intuitively visualized the heatmaps of pattern-specific components based on the topological position of electrode arrays and explored their physiological interpretability by examining the correspondence between the heatmaps and muscle activation areas.
期刊介绍:
Journal of NeuroEngineering and Rehabilitation considers manuscripts on all aspects of research that result from cross-fertilization of the fields of neuroscience, biomedical engineering, and physical medicine & rehabilitation.