以计算机为基础的自动干预识别心律失常初级保健患者的低镁血症。

IF 1.7 3区 医学 Q3 HEALTH CARE SCIENCES & SERVICES
Maite López-Garrigós, Miguel Ahumada, María Leiva-Salinas, Alvaro Blasco, Emilio Flores, Carlos Leiva-Salinas
{"title":"以计算机为基础的自动干预识别心律失常初级保健患者的低镁血症。","authors":"Maite López-Garrigós, Miguel Ahumada, María Leiva-Salinas, Alvaro Blasco, Emilio Flores, Carlos Leiva-Salinas","doi":"10.1097/PTS.0000000000001308","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Hypomagnesemia early diagnosis and consequently early, timely magnesium supplementation is of utmost benefit, but it often goes underdiagnosed. The objective was to show and monitor an intervention to identify hypomagnesemia in patients with arrhythmia.</p><p><strong>Methods: </strong>A cross-sectional study was designed in the laboratory. In primary care patients, the Laboratory Information System would automatically add a serum magnesium test when sample availability is present in any request when a diagnosis of arrhythmia is made. We counted the number of detected patients with hypomagnesemia (serum magnesium <1.7 mg/dL, <0.7 mmol/L), and calculated the cost in reagent of each identified case.</p><p><strong>Results: </strong>In 430 patients with arrhythmia, serum magnesium was measured, and 41 (9.5%) had hypomagnesemia results. One patient showed severe hypomagnesemia values (<1.2 mg/dL and <0.49 mmol/L). Patients with a deficit were significantly (P<0.01) older than the total group of patients with normal magnesium values (66.3±13.2 versus 61.6±12.5). Each case represented a cost of 3.15€ in reagent.</p><p><strong>Conclusions: </strong>The automated computer-based intervention to identify patients with hypomagnesemia was useful and affordable, given the cost per detected case.</p>","PeriodicalId":48901,"journal":{"name":"Journal of Patient Safety","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automated Computerized-Based Intervention to Identify Hypomagnesemia in Primary Care Patients With Arrhythmia.\",\"authors\":\"Maite López-Garrigós, Miguel Ahumada, María Leiva-Salinas, Alvaro Blasco, Emilio Flores, Carlos Leiva-Salinas\",\"doi\":\"10.1097/PTS.0000000000001308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Hypomagnesemia early diagnosis and consequently early, timely magnesium supplementation is of utmost benefit, but it often goes underdiagnosed. The objective was to show and monitor an intervention to identify hypomagnesemia in patients with arrhythmia.</p><p><strong>Methods: </strong>A cross-sectional study was designed in the laboratory. In primary care patients, the Laboratory Information System would automatically add a serum magnesium test when sample availability is present in any request when a diagnosis of arrhythmia is made. We counted the number of detected patients with hypomagnesemia (serum magnesium <1.7 mg/dL, <0.7 mmol/L), and calculated the cost in reagent of each identified case.</p><p><strong>Results: </strong>In 430 patients with arrhythmia, serum magnesium was measured, and 41 (9.5%) had hypomagnesemia results. One patient showed severe hypomagnesemia values (<1.2 mg/dL and <0.49 mmol/L). Patients with a deficit were significantly (P<0.01) older than the total group of patients with normal magnesium values (66.3±13.2 versus 61.6±12.5). Each case represented a cost of 3.15€ in reagent.</p><p><strong>Conclusions: </strong>The automated computer-based intervention to identify patients with hypomagnesemia was useful and affordable, given the cost per detected case.</p>\",\"PeriodicalId\":48901,\"journal\":{\"name\":\"Journal of Patient Safety\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Patient Safety\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PTS.0000000000001308\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Patient Safety","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PTS.0000000000001308","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

摘要

目的:低镁血症的早期诊断,因此早期,及时补充镁是最大的好处,但它经常被误诊。目的是显示和监测一种干预措施,以识别心律失常患者的低镁血症。方法:在实验室设计横断面研究。在初级保健患者中,当样品可用时,实验室信息系统将自动添加血清镁测试,以满足心律失常诊断的任何要求。结果:430例心律失常患者中测定了血清镁含量,41例(9.5%)出现低镁血症。结论:考虑到每个检测病例的成本,以计算机为基础的自动干预来识别低镁血症患者是有用的和负担得起的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automated Computerized-Based Intervention to Identify Hypomagnesemia in Primary Care Patients With Arrhythmia.

Objectives: Hypomagnesemia early diagnosis and consequently early, timely magnesium supplementation is of utmost benefit, but it often goes underdiagnosed. The objective was to show and monitor an intervention to identify hypomagnesemia in patients with arrhythmia.

Methods: A cross-sectional study was designed in the laboratory. In primary care patients, the Laboratory Information System would automatically add a serum magnesium test when sample availability is present in any request when a diagnosis of arrhythmia is made. We counted the number of detected patients with hypomagnesemia (serum magnesium <1.7 mg/dL, <0.7 mmol/L), and calculated the cost in reagent of each identified case.

Results: In 430 patients with arrhythmia, serum magnesium was measured, and 41 (9.5%) had hypomagnesemia results. One patient showed severe hypomagnesemia values (<1.2 mg/dL and <0.49 mmol/L). Patients with a deficit were significantly (P<0.01) older than the total group of patients with normal magnesium values (66.3±13.2 versus 61.6±12.5). Each case represented a cost of 3.15€ in reagent.

Conclusions: The automated computer-based intervention to identify patients with hypomagnesemia was useful and affordable, given the cost per detected case.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Patient Safety
Journal of Patient Safety HEALTH CARE SCIENCES & SERVICES-
CiteScore
4.60
自引率
13.60%
发文量
302
期刊介绍: Journal of Patient Safety (ISSN 1549-8417; online ISSN 1549-8425) is dedicated to presenting research advances and field applications in every area of patient safety. While Journal of Patient Safety has a research emphasis, it also publishes articles describing near-miss opportunities, system modifications that are barriers to error, and the impact of regulatory changes on healthcare delivery. This mix of research and real-world findings makes Journal of Patient Safety a valuable resource across the breadth of health professions and from bench to bedside.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信