Zhengqi Zhang, Anita P Liu, Hongxia Wang, Hillary A Schuessler
{"title":"柱后变性辅助疏水相互作用色谱-质谱法用于快速深入鉴定半胱氨酸抗体-药物共轭物中的位置异构体。","authors":"Zhengqi Zhang, Anita P Liu, Hongxia Wang, Hillary A Schuessler","doi":"10.1016/j.jpba.2024.116635","DOIUrl":null,"url":null,"abstract":"<p><p>Antibody-drug conjugates (ADCs) represent a significant advancement in targeted cancer therapy, offering the potential to selectively deliver cytotoxic drugs to tumor cells while minimizing systemic toxicity. However, the structural complexity of ADCs, particularly those conjugated through cysteine residues, poses significant analytical challenges. Due to the hydrophobicity of ADCs, Hydrophobic interaction chromatography (HIC) is often the method of choice to analyze the drug-to-antibody ratio (DAR). However, it requires high-concentration salts, which are often incompatible with mass spectrometry (MS) analysis. By employing ammonium acetate as an MS-compatible salt and integrating a 4-way liquid junction cross configuration for simultaneous introduction of the makeup flow and splitting the flow right before coupling to a mass spectrometer, we achieve high-quality separation and sensitive mass spectrometric analysis. This innovative setup allows for simultaneous DAR measurement and positional isomer characterization by switching the makeup flow solvent from water to a denaturation solution. Our method offers a streamlined and effective approach to ADC characterization, facilitating the identification of positional isomers without the need for fractionation or multiple chromatographic steps. The versatility and robustness of this HIC-MS method are demonstrated through the analysis of two ADCs, highlighting its potential for broad application in ADC development and quality control.</p>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"255 ","pages":"116635"},"PeriodicalIF":3.1000,"publicationDate":"2024-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Post-column denaturation-assisted hydrophobic interaction chromatography-mass spectrometry for rapid and in-depth characterization of positional isomers in cysteine-based antibody-drug conjugates.\",\"authors\":\"Zhengqi Zhang, Anita P Liu, Hongxia Wang, Hillary A Schuessler\",\"doi\":\"10.1016/j.jpba.2024.116635\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Antibody-drug conjugates (ADCs) represent a significant advancement in targeted cancer therapy, offering the potential to selectively deliver cytotoxic drugs to tumor cells while minimizing systemic toxicity. However, the structural complexity of ADCs, particularly those conjugated through cysteine residues, poses significant analytical challenges. Due to the hydrophobicity of ADCs, Hydrophobic interaction chromatography (HIC) is often the method of choice to analyze the drug-to-antibody ratio (DAR). However, it requires high-concentration salts, which are often incompatible with mass spectrometry (MS) analysis. By employing ammonium acetate as an MS-compatible salt and integrating a 4-way liquid junction cross configuration for simultaneous introduction of the makeup flow and splitting the flow right before coupling to a mass spectrometer, we achieve high-quality separation and sensitive mass spectrometric analysis. This innovative setup allows for simultaneous DAR measurement and positional isomer characterization by switching the makeup flow solvent from water to a denaturation solution. Our method offers a streamlined and effective approach to ADC characterization, facilitating the identification of positional isomers without the need for fractionation or multiple chromatographic steps. The versatility and robustness of this HIC-MS method are demonstrated through the analysis of two ADCs, highlighting its potential for broad application in ADC development and quality control.</p>\",\"PeriodicalId\":16685,\"journal\":{\"name\":\"Journal of pharmaceutical and biomedical analysis\",\"volume\":\"255 \",\"pages\":\"116635\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmaceutical and biomedical analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jpba.2024.116635\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jpba.2024.116635","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Post-column denaturation-assisted hydrophobic interaction chromatography-mass spectrometry for rapid and in-depth characterization of positional isomers in cysteine-based antibody-drug conjugates.
Antibody-drug conjugates (ADCs) represent a significant advancement in targeted cancer therapy, offering the potential to selectively deliver cytotoxic drugs to tumor cells while minimizing systemic toxicity. However, the structural complexity of ADCs, particularly those conjugated through cysteine residues, poses significant analytical challenges. Due to the hydrophobicity of ADCs, Hydrophobic interaction chromatography (HIC) is often the method of choice to analyze the drug-to-antibody ratio (DAR). However, it requires high-concentration salts, which are often incompatible with mass spectrometry (MS) analysis. By employing ammonium acetate as an MS-compatible salt and integrating a 4-way liquid junction cross configuration for simultaneous introduction of the makeup flow and splitting the flow right before coupling to a mass spectrometer, we achieve high-quality separation and sensitive mass spectrometric analysis. This innovative setup allows for simultaneous DAR measurement and positional isomer characterization by switching the makeup flow solvent from water to a denaturation solution. Our method offers a streamlined and effective approach to ADC characterization, facilitating the identification of positional isomers without the need for fractionation or multiple chromatographic steps. The versatility and robustness of this HIC-MS method are demonstrated through the analysis of two ADCs, highlighting its potential for broad application in ADC development and quality control.
期刊介绍:
This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome.
Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.