多目标输电扩展:海上风电集成案例研究

Saroj Khanal;Christoph Graf;Zhirui Liang;Yury Dvorkin;Burçin Ünel
{"title":"多目标输电扩展:海上风电集成案例研究","authors":"Saroj Khanal;Christoph Graf;Zhirui Liang;Yury Dvorkin;Burçin Ünel","doi":"10.1109/TEMPR.2024.3390760","DOIUrl":null,"url":null,"abstract":"Despite ambitious offshore wind targets in the U.S. and globally, offshore grid planning guidance remains notably scarce, contrasting with well-established frameworks for onshore grids. This gap, alongside the increasing penetration of offshore wind and other clean-energy resources in onshore grids, highlights the urgent need for a coordinated planning framework. Our paper describes a multi-objective, multistage generation, storage and transmission expansion planning model to facilitate efficient and resilient large-scale adoption of offshore wind power. Recognizing regulatory emphasis and, in some cases, requirements to consider externalities, this model explicitly accounts for negative externalities: greenhouse gas emissions and local emission-induced air pollution. Utilizing an 8-zone ISO-NE test system and a 9-zone PJM test system, we explore grid expansion sensitivities such as impacts of optimizing Points of Interconnection (POIs) versus fixed POIs, negative externalities, and consideration of extreme operational scenarios. Our results indicate that accounting for negative externalities necessitates greater upfront investment in clean generation and storage (balanced by lower expected operational costs). Optimizing POIs could significantly reshape offshore topology or POIs, and lower total cost. Finally, accounting for extreme operational scenarios typically results in greater operational costs and sometimes may alter onshore line investment.","PeriodicalId":100639,"journal":{"name":"IEEE Transactions on Energy Markets, Policy and Regulation","volume":"2 4","pages":"519-535"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-Objective Transmission Expansion: An Offshore Wind Power Integration Case Study\",\"authors\":\"Saroj Khanal;Christoph Graf;Zhirui Liang;Yury Dvorkin;Burçin Ünel\",\"doi\":\"10.1109/TEMPR.2024.3390760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Despite ambitious offshore wind targets in the U.S. and globally, offshore grid planning guidance remains notably scarce, contrasting with well-established frameworks for onshore grids. This gap, alongside the increasing penetration of offshore wind and other clean-energy resources in onshore grids, highlights the urgent need for a coordinated planning framework. Our paper describes a multi-objective, multistage generation, storage and transmission expansion planning model to facilitate efficient and resilient large-scale adoption of offshore wind power. Recognizing regulatory emphasis and, in some cases, requirements to consider externalities, this model explicitly accounts for negative externalities: greenhouse gas emissions and local emission-induced air pollution. Utilizing an 8-zone ISO-NE test system and a 9-zone PJM test system, we explore grid expansion sensitivities such as impacts of optimizing Points of Interconnection (POIs) versus fixed POIs, negative externalities, and consideration of extreme operational scenarios. Our results indicate that accounting for negative externalities necessitates greater upfront investment in clean generation and storage (balanced by lower expected operational costs). Optimizing POIs could significantly reshape offshore topology or POIs, and lower total cost. Finally, accounting for extreme operational scenarios typically results in greater operational costs and sometimes may alter onshore line investment.\",\"PeriodicalId\":100639,\"journal\":{\"name\":\"IEEE Transactions on Energy Markets, Policy and Regulation\",\"volume\":\"2 4\",\"pages\":\"519-535\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Energy Markets, Policy and Regulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10504955/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Energy Markets, Policy and Regulation","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10504955/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

尽管美国和全球都有雄心勃勃的海上风电目标,但与完善的陆上电网框架相比,海上电网规划指南仍然非常缺乏。这一差距,加上海上风能和其他清洁能源在陆上电网中的日益普及,凸显了协调规划框架的迫切需要。本文描述了一个多目标、多阶段的发电、储存和输电扩展规划模型,以促进海上风电的高效和弹性大规模采用。认识到监管的重要性,以及在某些情况下考虑外部性的要求,该模型明确考虑了负外部性:温室气体排放和地方排放引起的空气污染。利用8区ISO-NE测试系统和9区PJM测试系统,我们探索了电网扩展的敏感性,如优化互联点(poi)与固定poi的影响、负外部性以及对极端操作场景的考虑。我们的研究结果表明,考虑到负外部性,需要在清洁发电和存储方面进行更多的前期投资(通过降低预期运营成本来平衡)。优化poi可以显著重塑海上拓扑结构或poi,并降低总成本。最后,考虑极端的操作场景通常会导致更高的操作成本,有时可能会改变陆上线路的投资。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-Objective Transmission Expansion: An Offshore Wind Power Integration Case Study
Despite ambitious offshore wind targets in the U.S. and globally, offshore grid planning guidance remains notably scarce, contrasting with well-established frameworks for onshore grids. This gap, alongside the increasing penetration of offshore wind and other clean-energy resources in onshore grids, highlights the urgent need for a coordinated planning framework. Our paper describes a multi-objective, multistage generation, storage and transmission expansion planning model to facilitate efficient and resilient large-scale adoption of offshore wind power. Recognizing regulatory emphasis and, in some cases, requirements to consider externalities, this model explicitly accounts for negative externalities: greenhouse gas emissions and local emission-induced air pollution. Utilizing an 8-zone ISO-NE test system and a 9-zone PJM test system, we explore grid expansion sensitivities such as impacts of optimizing Points of Interconnection (POIs) versus fixed POIs, negative externalities, and consideration of extreme operational scenarios. Our results indicate that accounting for negative externalities necessitates greater upfront investment in clean generation and storage (balanced by lower expected operational costs). Optimizing POIs could significantly reshape offshore topology or POIs, and lower total cost. Finally, accounting for extreme operational scenarios typically results in greater operational costs and sometimes may alter onshore line investment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信