国产机器人辅助单腔人工膝关节置换术可提高假体置放精度,短期疗效较好。

IF 1.6 4区 医学
Rongxin Sun, Wusiman Yilihamujiang, Abulaiti Aierxiding, Gang Cheng, Zhoujun Zhu, Zhang Lei, Jian Gao, Guangjun Zhong, Maimaitiyiming Mieradili, Yeersheng Releken, Kan Jiang
{"title":"国产机器人辅助单腔人工膝关节置换术可提高假体置放精度,短期疗效较好。","authors":"Rongxin Sun, Wusiman Yilihamujiang, Abulaiti Aierxiding, Gang Cheng, Zhoujun Zhu, Zhang Lei, Jian Gao, Guangjun Zhong, Maimaitiyiming Mieradili, Yeersheng Releken, Kan Jiang","doi":"10.1177/10225536241298040","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this study was to assess whether China-made robot-assisted medial UKA can improve prosthesis placement accuracy and yield superior short-term outcomes compared with conventional UKA.</p><p><strong>Methods: </strong>50 patients who underwent initial medial UKA were included in this single-center, prospective, parallel, randomized, controlled trial. Preoperatively, patients were randomly categorized the robot-assisted UKA group and conventional UKA group. The operation time, intraoperative blood loss, postoperative pain scores (VAS scores at 24 h, 72 h, and 3 months post-surgery), KSS scores (clinical and functional scores), and knee range of motion (ROM) were compared between the two groups. The coronal deviation values of the femoral component, tibial component, and knee joint line height change were also compared between the two groups.</p><p><strong>Results: </strong>The deviations in tibial component coronal plane alignment, femoral component coronal plane alignment, and joint line height change were significantly smaller in the robot-assisted group compared to those in the conventional group (<i>p</i> < 0.05). The operation time of the robot-assisted group was longer than that of the conventional group (<i>p</i> < 0.05). At 24 h and 72 h postoperatively, patients in the robot-assisted group reported lower VAS scores compared to those in the conventional group (<i>p</i> < 0.05). No significant differences were observed between the two groups regarding intraoperative bloodloss, the VAS scores at 3 months postoperatively, the KSS scores (clinical scores and functional scores) at 3 months postoperatively, and the Knee range of motion at 3 months postoperatively.</p><p><strong>Conclusions: </strong>The China-made UKA robot can enhance the precision of prosthesis placement, yielding favorable short-term therapeutic outcomes.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"32 3","pages":"10225536241298040"},"PeriodicalIF":1.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"China-made robot-assisted unicompartmental knee arthroplasty can enhance the precision of prosthesis placement and yield better short-term efficacy.\",\"authors\":\"Rongxin Sun, Wusiman Yilihamujiang, Abulaiti Aierxiding, Gang Cheng, Zhoujun Zhu, Zhang Lei, Jian Gao, Guangjun Zhong, Maimaitiyiming Mieradili, Yeersheng Releken, Kan Jiang\",\"doi\":\"10.1177/10225536241298040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The purpose of this study was to assess whether China-made robot-assisted medial UKA can improve prosthesis placement accuracy and yield superior short-term outcomes compared with conventional UKA.</p><p><strong>Methods: </strong>50 patients who underwent initial medial UKA were included in this single-center, prospective, parallel, randomized, controlled trial. Preoperatively, patients were randomly categorized the robot-assisted UKA group and conventional UKA group. The operation time, intraoperative blood loss, postoperative pain scores (VAS scores at 24 h, 72 h, and 3 months post-surgery), KSS scores (clinical and functional scores), and knee range of motion (ROM) were compared between the two groups. The coronal deviation values of the femoral component, tibial component, and knee joint line height change were also compared between the two groups.</p><p><strong>Results: </strong>The deviations in tibial component coronal plane alignment, femoral component coronal plane alignment, and joint line height change were significantly smaller in the robot-assisted group compared to those in the conventional group (<i>p</i> < 0.05). The operation time of the robot-assisted group was longer than that of the conventional group (<i>p</i> < 0.05). At 24 h and 72 h postoperatively, patients in the robot-assisted group reported lower VAS scores compared to those in the conventional group (<i>p</i> < 0.05). No significant differences were observed between the two groups regarding intraoperative bloodloss, the VAS scores at 3 months postoperatively, the KSS scores (clinical scores and functional scores) at 3 months postoperatively, and the Knee range of motion at 3 months postoperatively.</p><p><strong>Conclusions: </strong>The China-made UKA robot can enhance the precision of prosthesis placement, yielding favorable short-term therapeutic outcomes.</p>\",\"PeriodicalId\":16608,\"journal\":{\"name\":\"Journal of Orthopaedic Surgery\",\"volume\":\"32 3\",\"pages\":\"10225536241298040\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10225536241298040\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536241298040","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究的目的是评估中国制造的机器人辅助医疗UKA与传统的UKA相比,是否可以提高假体放置的准确性并获得更好的短期效果。方法:本研究采用单中心、前瞻性、平行、随机、对照试验,纳入50例首次内侧UKA患者。术前将患者随机分为机器人辅助UKA组和常规UKA组。比较两组患者的手术时间、术中出血量、术后疼痛评分(术后24小时、72小时、3个月VAS评分)、KSS评分(临床及功能评分)、膝关节活动度(ROM)。比较两组股骨假体、胫骨假体冠状偏差值及膝关节线高变化。结果:机器人辅助组胫骨假体冠状面对齐偏差、股骨假体冠状面对齐偏差、关节线高度变化均明显小于常规组(p < 0.05)。机器人辅助组手术时间明显长于常规组(p < 0.05)。在术后24 h和72 h,机器人辅助组患者的VAS评分低于常规组(p < 0.05)。两组患者术中出血量、术后3个月VAS评分、术后3个月KSS评分(临床评分和功能评分)、术后3个月膝关节活动度均无显著差异。结论:国产UKA机器人可提高义肢放置精度,短期治疗效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
China-made robot-assisted unicompartmental knee arthroplasty can enhance the precision of prosthesis placement and yield better short-term efficacy.

Background: The purpose of this study was to assess whether China-made robot-assisted medial UKA can improve prosthesis placement accuracy and yield superior short-term outcomes compared with conventional UKA.

Methods: 50 patients who underwent initial medial UKA were included in this single-center, prospective, parallel, randomized, controlled trial. Preoperatively, patients were randomly categorized the robot-assisted UKA group and conventional UKA group. The operation time, intraoperative blood loss, postoperative pain scores (VAS scores at 24 h, 72 h, and 3 months post-surgery), KSS scores (clinical and functional scores), and knee range of motion (ROM) were compared between the two groups. The coronal deviation values of the femoral component, tibial component, and knee joint line height change were also compared between the two groups.

Results: The deviations in tibial component coronal plane alignment, femoral component coronal plane alignment, and joint line height change were significantly smaller in the robot-assisted group compared to those in the conventional group (p < 0.05). The operation time of the robot-assisted group was longer than that of the conventional group (p < 0.05). At 24 h and 72 h postoperatively, patients in the robot-assisted group reported lower VAS scores compared to those in the conventional group (p < 0.05). No significant differences were observed between the two groups regarding intraoperative bloodloss, the VAS scores at 3 months postoperatively, the KSS scores (clinical scores and functional scores) at 3 months postoperatively, and the Knee range of motion at 3 months postoperatively.

Conclusions: The China-made UKA robot can enhance the precision of prosthesis placement, yielding favorable short-term therapeutic outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
91
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信