{"title":"经口机器人声门后瘢痕溶解和部分杓骨切除术:TORS在良性声门手术中的新应用报告。","authors":"Bharat Akhanda Panuganti, Harishanker Jeyarajan","doi":"10.1177/00034894241304930","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Transoral robotic surgery (TORS) for benign glottic conditions is scarcely represented in the literature. We aimed in this study to report on the technical feasibility of an explicitly transoral robotic approach for a patient with posterior glottic stenosis, and to highlight extant limitations in exposure and robotic instrumentation of the glottis.</p><p><strong>Methods: </strong>Retrospective chart review of a single patient undergoing a TORS approach to maximize the posterior glottic aperture.</p><p><strong>Results: </strong>A 42-year-old female patient with posterior glottic stenosis and a tracheotomy was consented for a robotic posterior glottic scar lysis, KTP-laser assisted partial arytenoidectomy, balloon dilation, and steroid injection. The da Vinci Intuitive Surgical single-port robotic platform was used with 2 robotic arms (needle driver and scissors), and an FK-WO transoral retractor with a straight tongue blade was deployed to facilitate endolaryngeal exposure. KTP laser fiber was passed through a robotic, semi-flexible drop-in guide, and manipulated with the needle driver. Case duration was 40 minutes. There were no perioperative or immediate post-operative complications noted on short-term follow-up.</p><p><strong>Conclusion: </strong>We demonstrate technical feasibility and equipoise between an explicitly robotic approach and a standard endoscopic approach to posterior glottic stenosis, a common glottic condition. Further technological development and adaptation of surgical technique are necessary to advance benign robotic laryngeal surgery.</p>","PeriodicalId":50975,"journal":{"name":"Annals of Otology Rhinology and Laryngology","volume":" ","pages":"294-296"},"PeriodicalIF":1.3000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transoral Robotic Posterior Glottic Scar Lysis and Partial Arytenoidectomy: Report of a Novel Application of TORS for Benign Glottic Surgery.\",\"authors\":\"Bharat Akhanda Panuganti, Harishanker Jeyarajan\",\"doi\":\"10.1177/00034894241304930\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Transoral robotic surgery (TORS) for benign glottic conditions is scarcely represented in the literature. We aimed in this study to report on the technical feasibility of an explicitly transoral robotic approach for a patient with posterior glottic stenosis, and to highlight extant limitations in exposure and robotic instrumentation of the glottis.</p><p><strong>Methods: </strong>Retrospective chart review of a single patient undergoing a TORS approach to maximize the posterior glottic aperture.</p><p><strong>Results: </strong>A 42-year-old female patient with posterior glottic stenosis and a tracheotomy was consented for a robotic posterior glottic scar lysis, KTP-laser assisted partial arytenoidectomy, balloon dilation, and steroid injection. The da Vinci Intuitive Surgical single-port robotic platform was used with 2 robotic arms (needle driver and scissors), and an FK-WO transoral retractor with a straight tongue blade was deployed to facilitate endolaryngeal exposure. KTP laser fiber was passed through a robotic, semi-flexible drop-in guide, and manipulated with the needle driver. Case duration was 40 minutes. There were no perioperative or immediate post-operative complications noted on short-term follow-up.</p><p><strong>Conclusion: </strong>We demonstrate technical feasibility and equipoise between an explicitly robotic approach and a standard endoscopic approach to posterior glottic stenosis, a common glottic condition. Further technological development and adaptation of surgical technique are necessary to advance benign robotic laryngeal surgery.</p>\",\"PeriodicalId\":50975,\"journal\":{\"name\":\"Annals of Otology Rhinology and Laryngology\",\"volume\":\" \",\"pages\":\"294-296\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Otology Rhinology and Laryngology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00034894241304930\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Otology Rhinology and Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00034894241304930","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
Transoral Robotic Posterior Glottic Scar Lysis and Partial Arytenoidectomy: Report of a Novel Application of TORS for Benign Glottic Surgery.
Objectives: Transoral robotic surgery (TORS) for benign glottic conditions is scarcely represented in the literature. We aimed in this study to report on the technical feasibility of an explicitly transoral robotic approach for a patient with posterior glottic stenosis, and to highlight extant limitations in exposure and robotic instrumentation of the glottis.
Methods: Retrospective chart review of a single patient undergoing a TORS approach to maximize the posterior glottic aperture.
Results: A 42-year-old female patient with posterior glottic stenosis and a tracheotomy was consented for a robotic posterior glottic scar lysis, KTP-laser assisted partial arytenoidectomy, balloon dilation, and steroid injection. The da Vinci Intuitive Surgical single-port robotic platform was used with 2 robotic arms (needle driver and scissors), and an FK-WO transoral retractor with a straight tongue blade was deployed to facilitate endolaryngeal exposure. KTP laser fiber was passed through a robotic, semi-flexible drop-in guide, and manipulated with the needle driver. Case duration was 40 minutes. There were no perioperative or immediate post-operative complications noted on short-term follow-up.
Conclusion: We demonstrate technical feasibility and equipoise between an explicitly robotic approach and a standard endoscopic approach to posterior glottic stenosis, a common glottic condition. Further technological development and adaptation of surgical technique are necessary to advance benign robotic laryngeal surgery.
期刊介绍:
The Annals of Otology, Rhinology & Laryngology publishes original manuscripts of clinical and research importance in otolaryngology–head and neck medicine and surgery, otology, neurotology, bronchoesophagology, laryngology, rhinology, head and neck oncology and surgery, plastic and reconstructive surgery, pediatric otolaryngology, audiology, and speech pathology. In-depth studies (supplements), papers of historical interest, and reviews of computer software and applications in otolaryngology are also published, as well as imaging, pathology, and clinicopathology studies, book reviews, and letters to the editor. AOR is the official journal of the American Broncho-Esophagological Association.