CT针引导下经皮胶栓塞修复肋间搭桥术假性动脉瘤1例。

IF 1 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE
Vascular Pub Date : 2024-12-05 DOI:10.1177/17085381241305177
James Moroney, Andrew Plumb, Matthew Scheidt, Michael Malinowski
{"title":"CT针引导下经皮胶栓塞修复肋间搭桥术假性动脉瘤1例。","authors":"James Moroney, Andrew Plumb, Matthew Scheidt, Michael Malinowski","doi":"10.1177/17085381241305177","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Pseudoaneurysm formation in connective tissue patients postoperatively can be a challenging and life-threatening problem to treat. Repair of an aorta to intercostal bypass graft pseudoaneurysm post open thoracoabdominal aortic aneurysm repair by percutaneous glue embolization utilizing Dyna CT Needle Guidance technology is a safe, minimally invasive method with low morbidity and short post-procedural recovery.</p><p><strong>Methods: </strong>A 30-year-old male with suspected connective tissue disorder who developed a Type B aortic dissection complicated by limb threatening right lower extremity ischemia treated with left-to-right fem-fem bypass and RLE fasciotomies. His thoracic aortic dissection subsequently was repaired urgently for persistent chest pain and rapid aortic expansion by open thoracoabdominal aortic aneurysm repair with aorta to intercostal bypass graft. Seven weeks postop patient presented with hemoptysis and was noted to have an enlarging T9 intercostal pseudoaneurysm requiring repair.</p><p><strong>Results and conclusions: </strong>Post discharge follow-up thoracic CTA performed showed complete resolution of the T9 intercostal pseudoaneurysm. Therefore, percutaneous NBCA glue embolization with iGuide technology is a viable alternative to open thoracic pseudoaneurysm repair and offers distinct advantages over other imaging modalities for localization.</p>","PeriodicalId":23549,"journal":{"name":"Vascular","volume":" ","pages":"17085381241305177"},"PeriodicalIF":1.0000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intercostal bypass graft pseudoaneurysm repaired with percutaneous glue embolization utilizing CT needle guidance: A case report.\",\"authors\":\"James Moroney, Andrew Plumb, Matthew Scheidt, Michael Malinowski\",\"doi\":\"10.1177/17085381241305177\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Pseudoaneurysm formation in connective tissue patients postoperatively can be a challenging and life-threatening problem to treat. Repair of an aorta to intercostal bypass graft pseudoaneurysm post open thoracoabdominal aortic aneurysm repair by percutaneous glue embolization utilizing Dyna CT Needle Guidance technology is a safe, minimally invasive method with low morbidity and short post-procedural recovery.</p><p><strong>Methods: </strong>A 30-year-old male with suspected connective tissue disorder who developed a Type B aortic dissection complicated by limb threatening right lower extremity ischemia treated with left-to-right fem-fem bypass and RLE fasciotomies. His thoracic aortic dissection subsequently was repaired urgently for persistent chest pain and rapid aortic expansion by open thoracoabdominal aortic aneurysm repair with aorta to intercostal bypass graft. Seven weeks postop patient presented with hemoptysis and was noted to have an enlarging T9 intercostal pseudoaneurysm requiring repair.</p><p><strong>Results and conclusions: </strong>Post discharge follow-up thoracic CTA performed showed complete resolution of the T9 intercostal pseudoaneurysm. Therefore, percutaneous NBCA glue embolization with iGuide technology is a viable alternative to open thoracic pseudoaneurysm repair and offers distinct advantages over other imaging modalities for localization.</p>\",\"PeriodicalId\":23549,\"journal\":{\"name\":\"Vascular\",\"volume\":\" \",\"pages\":\"17085381241305177\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vascular\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17085381241305177\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17085381241305177","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

目的:结缔组织患者术后假性动脉瘤形成是一个具有挑战性和危及生命的问题。应用Dyna CT针导向技术经皮胶栓塞修复开放性胸腹主动脉瘤是一种安全、微创、发病率低、术后恢复时间短的方法。方法:1例30岁男性,疑似结缔组织病变,B型主动脉夹层合并肢体威胁性右下肢缺血,行左至右femm -fem搭桥和RLE筋膜切开术治疗。由于持续的胸痛和快速的主动脉扩张,他的胸主动脉夹层随后被紧急修复,通过开胸腹主动脉瘤修复和主动脉肋间旁路移植术。术后7周,患者出现咯血,T9肋间假性动脉瘤增大,需要修复。结果和结论:出院后随访胸部CTA显示T9肋间假性动脉瘤完全消退。因此,经皮NBCA胶栓塞与guidide技术是开放性胸腔假性动脉瘤修复的可行选择,与其他成像方式相比具有明显的定位优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intercostal bypass graft pseudoaneurysm repaired with percutaneous glue embolization utilizing CT needle guidance: A case report.

Objectives: Pseudoaneurysm formation in connective tissue patients postoperatively can be a challenging and life-threatening problem to treat. Repair of an aorta to intercostal bypass graft pseudoaneurysm post open thoracoabdominal aortic aneurysm repair by percutaneous glue embolization utilizing Dyna CT Needle Guidance technology is a safe, minimally invasive method with low morbidity and short post-procedural recovery.

Methods: A 30-year-old male with suspected connective tissue disorder who developed a Type B aortic dissection complicated by limb threatening right lower extremity ischemia treated with left-to-right fem-fem bypass and RLE fasciotomies. His thoracic aortic dissection subsequently was repaired urgently for persistent chest pain and rapid aortic expansion by open thoracoabdominal aortic aneurysm repair with aorta to intercostal bypass graft. Seven weeks postop patient presented with hemoptysis and was noted to have an enlarging T9 intercostal pseudoaneurysm requiring repair.

Results and conclusions: Post discharge follow-up thoracic CTA performed showed complete resolution of the T9 intercostal pseudoaneurysm. Therefore, percutaneous NBCA glue embolization with iGuide technology is a viable alternative to open thoracic pseudoaneurysm repair and offers distinct advantages over other imaging modalities for localization.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vascular
Vascular 医学-外周血管病
CiteScore
2.30
自引率
9.10%
发文量
196
审稿时长
6-12 weeks
期刊介绍: Vascular provides readers with new and unusual up-to-date articles and case reports focusing on vascular and endovascular topics. It is a highly international forum for the discussion and debate of all aspects of this distinct surgical specialty. It also features opinion pieces, literature reviews and controversial issues presented from various points of view.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信