Leon L Su, Daniel T Secor, Alyssa K McGary, Michelle C Nguyen, Caroline C Jadlowiec, Lance A Williams, Theresa N Kinard, Jill Adamski, Alex D Stoker, Peter E Frasco
{"title":"凝血弹性成像参数证明肝移植中恒温机器灌注维持凝血功能。","authors":"Leon L Su, Daniel T Secor, Alyssa K McGary, Michelle C Nguyen, Caroline C Jadlowiec, Lance A Williams, Theresa N Kinard, Jill Adamski, Alex D Stoker, Peter E Frasco","doi":"10.1097/LVT.0000000000000507","DOIUrl":null,"url":null,"abstract":"<p><p>The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.</p>","PeriodicalId":18072,"journal":{"name":"Liver Transplantation","volume":" ","pages":"464-475"},"PeriodicalIF":4.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters.\",\"authors\":\"Leon L Su, Daniel T Secor, Alyssa K McGary, Michelle C Nguyen, Caroline C Jadlowiec, Lance A Williams, Theresa N Kinard, Jill Adamski, Alex D Stoker, Peter E Frasco\",\"doi\":\"10.1097/LVT.0000000000000507\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.</p>\",\"PeriodicalId\":18072,\"journal\":{\"name\":\"Liver Transplantation\",\"volume\":\" \",\"pages\":\"464-475\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Liver Transplantation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/LVT.0000000000000507\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Liver Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/LVT.0000000000000507","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters.
The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.
期刊介绍:
Since the first application of liver transplantation in a clinical situation was reported more than twenty years ago, there has been a great deal of growth in this field and more is anticipated. As an official publication of the AASLD, Liver Transplantation delivers current, peer-reviewed articles on liver transplantation, liver surgery, and chronic liver disease — the information necessary to keep abreast of this evolving specialty.