凝血弹性成像参数证明肝移植中恒温机器灌注维持凝血功能。

IF 4.7 2区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY
Liver Transplantation Pub Date : 2025-04-01 Epub Date: 2024-10-14 DOI:10.1097/LVT.0000000000000507
Leon L Su, Daniel T Secor, Alyssa K McGary, Michelle C Nguyen, Caroline C Jadlowiec, Lance A Williams, Theresa N Kinard, Jill Adamski, Alex D Stoker, Peter E Frasco
{"title":"凝血弹性成像参数证明肝移植中恒温机器灌注维持凝血功能。","authors":"Leon L Su, Daniel T Secor, Alyssa K McGary, Michelle C Nguyen, Caroline C Jadlowiec, Lance A Williams, Theresa N Kinard, Jill Adamski, Alex D Stoker, Peter E Frasco","doi":"10.1097/LVT.0000000000000507","DOIUrl":null,"url":null,"abstract":"<p><p>The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.</p>","PeriodicalId":18072,"journal":{"name":"Liver Transplantation","volume":" ","pages":"464-475"},"PeriodicalIF":4.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters.\",\"authors\":\"Leon L Su, Daniel T Secor, Alyssa K McGary, Michelle C Nguyen, Caroline C Jadlowiec, Lance A Williams, Theresa N Kinard, Jill Adamski, Alex D Stoker, Peter E Frasco\",\"doi\":\"10.1097/LVT.0000000000000507\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.</p>\",\"PeriodicalId\":18072,\"journal\":{\"name\":\"Liver Transplantation\",\"volume\":\" \",\"pages\":\"464-475\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Liver Transplantation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/LVT.0000000000000507\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Liver Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/LVT.0000000000000507","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在肝移植中使用恒温机器灌注(NMP)而不是静态冷藏已被证明可以降低移植后早期异体移植物功能障碍、原发性无功能和缺血性胆管病的风险,并且其越来越多的使用在边缘肝脏的扩大利用中发挥了作用。虽然研究表明使用NMP比静态冷库保存可以改善临床结果,但反映NMP肝脏质量和活力的实时术中数据有限。这项回顾性的单中心研究通过血栓弹性成像和常规凝血试验对首次肝移植受者的合成凝血功能进行评估,比较了NMP和静态冷库肝脏。其次,回顾了两组患者的输血使用情况。研究纳入了186例循环死亡后接受供体同种异体移植的肝移植受者,其中99例(53%)同种异体移植保存在静态冷库中,87例(47%)同种异体移植放置在TransMedics器官护理系统中。研究结果显示,与静态冷藏肝脏相比,经TransMedics器官护理系统支持的NMP肝脏在灌注后的合成凝血功能增加,纤维蛋白溶解过多减少,并且与传统凝血试验相比,这些发现可以更好地实时反映在血栓弹性成像监测中。再灌注后,与静态冷库组相比,NMP组的血液制品输注量显著减少。总的来说,我们确定术中血栓弹性成像可以提供实时数据来评估再灌注肝脏质量和活力的一个方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters.

The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Liver Transplantation
Liver Transplantation 医学-外科
CiteScore
7.40
自引率
6.50%
发文量
254
审稿时长
3-8 weeks
期刊介绍: Since the first application of liver transplantation in a clinical situation was reported more than twenty years ago, there has been a great deal of growth in this field and more is anticipated. As an official publication of the AASLD, Liver Transplantation delivers current, peer-reviewed articles on liver transplantation, liver surgery, and chronic liver disease — the information necessary to keep abreast of this evolving specialty.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信