Irl B Hirsch, Dorrine Khakpour, Jeffrey Joseph, Michi M Shinohara, Ruikang K Wang, Ulrike Klueh, Donald Kreutzner, Jean-Pierre Riveline, Pauline Jacquemier, Lisa Maier, Michael T Longaker, Christopher G Parkin, Thomas Pieber, Andrea Kalus
{"title":"DERMIS研究:方法、结果和对未来的影响。","authors":"Irl B Hirsch, Dorrine Khakpour, Jeffrey Joseph, Michi M Shinohara, Ruikang K Wang, Ulrike Klueh, Donald Kreutzner, Jean-Pierre Riveline, Pauline Jacquemier, Lisa Maier, Michael T Longaker, Christopher G Parkin, Thomas Pieber, Andrea Kalus","doi":"10.1177/19322968241298005","DOIUrl":null,"url":null,"abstract":"<p><p>Ongoing innovation in diabetes technologies has led to the development of advanced tools such as automated insulin delivery (AID) systems that adjust insulin delivery in response to current and predicted glucose levels, residual insulin action, and other inputs (eg, meal and exercise announcements). However, infusion sets continue to be the \"Achilles heel\" of accurate and precise insulin delivery and continued device use. A recent study by Kalus et al (DERMIS Study) revealed higher vessel density and signals of inflammation by optical coherence tomography (OCT), in addition to increased inflammation, fat necrosis, fibrosis, and eosinophilic infiltration by histopathology. Although the study provided a comprehensive description of what was happening, the results raise important questions that require additional research. On February 29, 2024, the Leona M. and Harry B. Helmsley Charitable Trust sponsored a conference to begin addressing these issues. This article summarizes the DERMIS study findings and testing methodologies discussed at the conference and proposes the next steps for developing insulin infusion sets that reduce the variability in insulin delivery and extend wear.</p>","PeriodicalId":15475,"journal":{"name":"Journal of Diabetes Science and Technology","volume":" ","pages":"19322968241298005"},"PeriodicalIF":4.1000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11618839/pdf/","citationCount":"0","resultStr":"{\"title\":\"The DERMIS Study: Methodologies, Results, and Implications for the Future.\",\"authors\":\"Irl B Hirsch, Dorrine Khakpour, Jeffrey Joseph, Michi M Shinohara, Ruikang K Wang, Ulrike Klueh, Donald Kreutzner, Jean-Pierre Riveline, Pauline Jacquemier, Lisa Maier, Michael T Longaker, Christopher G Parkin, Thomas Pieber, Andrea Kalus\",\"doi\":\"10.1177/19322968241298005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ongoing innovation in diabetes technologies has led to the development of advanced tools such as automated insulin delivery (AID) systems that adjust insulin delivery in response to current and predicted glucose levels, residual insulin action, and other inputs (eg, meal and exercise announcements). However, infusion sets continue to be the \\\"Achilles heel\\\" of accurate and precise insulin delivery and continued device use. A recent study by Kalus et al (DERMIS Study) revealed higher vessel density and signals of inflammation by optical coherence tomography (OCT), in addition to increased inflammation, fat necrosis, fibrosis, and eosinophilic infiltration by histopathology. Although the study provided a comprehensive description of what was happening, the results raise important questions that require additional research. On February 29, 2024, the Leona M. and Harry B. Helmsley Charitable Trust sponsored a conference to begin addressing these issues. This article summarizes the DERMIS study findings and testing methodologies discussed at the conference and proposes the next steps for developing insulin infusion sets that reduce the variability in insulin delivery and extend wear.</p>\",\"PeriodicalId\":15475,\"journal\":{\"name\":\"Journal of Diabetes Science and Technology\",\"volume\":\" \",\"pages\":\"19322968241298005\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11618839/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Diabetes Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19322968241298005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Diabetes Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19322968241298005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
The DERMIS Study: Methodologies, Results, and Implications for the Future.
Ongoing innovation in diabetes technologies has led to the development of advanced tools such as automated insulin delivery (AID) systems that adjust insulin delivery in response to current and predicted glucose levels, residual insulin action, and other inputs (eg, meal and exercise announcements). However, infusion sets continue to be the "Achilles heel" of accurate and precise insulin delivery and continued device use. A recent study by Kalus et al (DERMIS Study) revealed higher vessel density and signals of inflammation by optical coherence tomography (OCT), in addition to increased inflammation, fat necrosis, fibrosis, and eosinophilic infiltration by histopathology. Although the study provided a comprehensive description of what was happening, the results raise important questions that require additional research. On February 29, 2024, the Leona M. and Harry B. Helmsley Charitable Trust sponsored a conference to begin addressing these issues. This article summarizes the DERMIS study findings and testing methodologies discussed at the conference and proposes the next steps for developing insulin infusion sets that reduce the variability in insulin delivery and extend wear.
期刊介绍:
The Journal of Diabetes Science and Technology (JDST) is a bi-monthly, peer-reviewed scientific journal published by the Diabetes Technology Society. JDST covers scientific and clinical aspects of diabetes technology including glucose monitoring, insulin and metabolic peptide delivery, the artificial pancreas, digital health, precision medicine, social media, cybersecurity, software for modeling, physiologic monitoring, technology for managing obesity, and diagnostic tests of glycation. The journal also covers the development and use of mobile applications and wireless communication, as well as bioengineered tools such as MEMS, new biomaterials, and nanotechnology to develop new sensors. Articles in JDST cover both basic research and clinical applications of technologies being developed to help people with diabetes.