{"title":"改良全髋关节置换术治疗海绵状金属<s:1>贝克髋关节假体伴重复股骨柄骨折及假体周围骨折1例。","authors":"Takuya Nakai, Shigeo Fukunishi","doi":"10.5371/hp.2024.36.4.320","DOIUrl":null,"url":null,"abstract":"<p><p>The fully porous structure of the Lübeck prosthesis is designed to closely resemble cancellous bone. Several studies have reported 'good' to 'excellent' mid- to long-term results for use of the Lübeck, but stem fractures have been reported as a complication. We report on the case of an 85-year-old patient who underwent total hip arthroplasty (THA) using the Lübeck more than 25 years ago who underwent revision surgery for management of two periprosthetic femoral fractures and a stem fracture. A subtrochanteric fracture and a fracture of the stem were observed on radiographs, and a radiolucent line was observed in the proximal portion of the stem and a well-fixed distal portion was observed. Revision THA using a proximal femoral replacement stem and resection of the proximal femur has been proven as an effective procedure for treatment of an elderly patient with a fractured Lübeck stem with a well-fixed distal stem.</p>","PeriodicalId":73239,"journal":{"name":"Hip & pelvis","volume":"36 4","pages":"320-325"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11638748/pdf/","citationCount":"0","resultStr":"{\"title\":\"Revision Total Hip Arthroplasty for Spongy Metal Lübeck Hip Prosthesis with Repeated Stem Fracture and Periprosthetic Femur Fractures: A Case Report.\",\"authors\":\"Takuya Nakai, Shigeo Fukunishi\",\"doi\":\"10.5371/hp.2024.36.4.320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The fully porous structure of the Lübeck prosthesis is designed to closely resemble cancellous bone. Several studies have reported 'good' to 'excellent' mid- to long-term results for use of the Lübeck, but stem fractures have been reported as a complication. We report on the case of an 85-year-old patient who underwent total hip arthroplasty (THA) using the Lübeck more than 25 years ago who underwent revision surgery for management of two periprosthetic femoral fractures and a stem fracture. A subtrochanteric fracture and a fracture of the stem were observed on radiographs, and a radiolucent line was observed in the proximal portion of the stem and a well-fixed distal portion was observed. Revision THA using a proximal femoral replacement stem and resection of the proximal femur has been proven as an effective procedure for treatment of an elderly patient with a fractured Lübeck stem with a well-fixed distal stem.</p>\",\"PeriodicalId\":73239,\"journal\":{\"name\":\"Hip & pelvis\",\"volume\":\"36 4\",\"pages\":\"320-325\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11638748/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hip & pelvis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5371/hp.2024.36.4.320\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hip & pelvis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5371/hp.2024.36.4.320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Revision Total Hip Arthroplasty for Spongy Metal Lübeck Hip Prosthesis with Repeated Stem Fracture and Periprosthetic Femur Fractures: A Case Report.
The fully porous structure of the Lübeck prosthesis is designed to closely resemble cancellous bone. Several studies have reported 'good' to 'excellent' mid- to long-term results for use of the Lübeck, but stem fractures have been reported as a complication. We report on the case of an 85-year-old patient who underwent total hip arthroplasty (THA) using the Lübeck more than 25 years ago who underwent revision surgery for management of two periprosthetic femoral fractures and a stem fracture. A subtrochanteric fracture and a fracture of the stem were observed on radiographs, and a radiolucent line was observed in the proximal portion of the stem and a well-fixed distal portion was observed. Revision THA using a proximal femoral replacement stem and resection of the proximal femur has been proven as an effective procedure for treatment of an elderly patient with a fractured Lübeck stem with a well-fixed distal stem.