超声心动图引导下无透视下三尖瓣经导管边缘对边缘修复技术及初步结果。

IF 1.9 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Reviews in cardiovascular medicine Pub Date : 2024-11-21 eCollection Date: 2024-11-01 DOI:10.31083/j.rcm2511413
Manchen Gao, Hao Shi, Cheng Wang, Hong Meng, Jiande Wang, Da Zhu, Zhiling Luo, Chuangshi Wang, Ziping Li, Junke Chang, Fengwen Zhang, Xiangbin Pan, Shouzheng Wang
{"title":"超声心动图引导下无透视下三尖瓣经导管边缘对边缘修复技术及初步结果。","authors":"Manchen Gao, Hao Shi, Cheng Wang, Hong Meng, Jiande Wang, Da Zhu, Zhiling Luo, Chuangshi Wang, Ziping Li, Junke Chang, Fengwen Zhang, Xiangbin Pan, Shouzheng Wang","doi":"10.31083/j.rcm2511413","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Tricuspid transcatheter edge-to-edge repair (T-TEER) has emerged as an attractive option for severe tricuspid regurgitation (TR). To avoid the radiation exposure for both patients and medical staff, we propose a sole-echocardiography-guided method for T-TEER. The purpose of this article was to investigate the feasibility of sole-echocardiography-guided T-TEER.</p><p><strong>Methods: </strong>This was a retrospective observational study, including 43 patients who underwent sole-echocardiography-guided T-TEER at two medical centers in China between June 2022 and September 2023. Clinical and echocardiographic data were collected at baseline, discharge and 6-month follow-up.</p><p><strong>Results: </strong>Patients enrolled in this study were elderly (71.6 ± 8.2 years) with significant comorbidities, 67.4% had baseline massive or torrential TR and 76.7% were classified as New York Heart Association (NYHA) functional class III/IV. All patients achieved successful device implantation, and no severe device-related complications or mortality occurred during the follow-up period. Significantly reduced TR and reversed right ventricular remodeling were observed at 6-month follow-ups. Patients classified as NYHA functional class I/II increased from 23.3% at baseline to 81.4% at 6-month follow-up (<i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>Sole-echocardiography-guided T-TEER has a low incidence of complications and can effectively reduce TR. It is feasible to substitute conventional fluoroscopy and echocardiography guidance for echocardiography guidance alone. Further large-scale randomized controlled trials are needed to validate the safety, efficacy and patient benefits of this technique.</p>","PeriodicalId":20989,"journal":{"name":"Reviews in cardiovascular medicine","volume":"25 11","pages":"413"},"PeriodicalIF":1.9000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11607490/pdf/","citationCount":"0","resultStr":"{\"title\":\"Technique and Preliminary Results of Sole-echocardiography-guided Tricuspid Transcatheter Edge-to-edge Repair without the Use of Fluoroscopy.\",\"authors\":\"Manchen Gao, Hao Shi, Cheng Wang, Hong Meng, Jiande Wang, Da Zhu, Zhiling Luo, Chuangshi Wang, Ziping Li, Junke Chang, Fengwen Zhang, Xiangbin Pan, Shouzheng Wang\",\"doi\":\"10.31083/j.rcm2511413\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Tricuspid transcatheter edge-to-edge repair (T-TEER) has emerged as an attractive option for severe tricuspid regurgitation (TR). To avoid the radiation exposure for both patients and medical staff, we propose a sole-echocardiography-guided method for T-TEER. The purpose of this article was to investigate the feasibility of sole-echocardiography-guided T-TEER.</p><p><strong>Methods: </strong>This was a retrospective observational study, including 43 patients who underwent sole-echocardiography-guided T-TEER at two medical centers in China between June 2022 and September 2023. Clinical and echocardiographic data were collected at baseline, discharge and 6-month follow-up.</p><p><strong>Results: </strong>Patients enrolled in this study were elderly (71.6 ± 8.2 years) with significant comorbidities, 67.4% had baseline massive or torrential TR and 76.7% were classified as New York Heart Association (NYHA) functional class III/IV. All patients achieved successful device implantation, and no severe device-related complications or mortality occurred during the follow-up period. Significantly reduced TR and reversed right ventricular remodeling were observed at 6-month follow-ups. Patients classified as NYHA functional class I/II increased from 23.3% at baseline to 81.4% at 6-month follow-up (<i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>Sole-echocardiography-guided T-TEER has a low incidence of complications and can effectively reduce TR. It is feasible to substitute conventional fluoroscopy and echocardiography guidance for echocardiography guidance alone. Further large-scale randomized controlled trials are needed to validate the safety, efficacy and patient benefits of this technique.</p>\",\"PeriodicalId\":20989,\"journal\":{\"name\":\"Reviews in cardiovascular medicine\",\"volume\":\"25 11\",\"pages\":\"413\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11607490/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reviews in cardiovascular medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.31083/j.rcm2511413\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reviews in cardiovascular medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.31083/j.rcm2511413","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:三尖瓣经导管边缘到边缘修复(T-TEER)已成为严重三尖瓣反流(TR)的一种有吸引力的选择。为了避免对患者和医务人员的辐射暴露,我们提出了一种单超声心动图引导的T-TEER方法。本文的目的是探讨超声心动图单独引导T-TEER的可行性。方法:这是一项回顾性观察性研究,包括43名于2022年6月至2023年9月在中国两家医疗中心接受单超声心动图引导T-TEER的患者。在基线、出院和6个月随访时收集临床和超声心动图资料。结果:本研究纳入的患者为具有明显合并症的老年人(71.6±8.2岁),67.4%的患者基线有大量或重度TR, 76.7%的患者被归类为纽约心脏协会(NYHA)功能III/IV级。所有患者均成功植入器械,随访期间未发生严重的器械相关并发症或死亡。在6个月的随访中观察到显著降低的TR和逆转的右心室重构。NYHA功能级I/II的患者从基线时的23.3%增加到6个月随访时的81.4% (p < 0.001)。结论:单纯超声心动图引导下T-TEER并发症发生率低,可有效降低TR,用常规透视加超声心动图指导替代单纯超声心动图指导是可行的。需要进一步的大规模随机对照试验来验证该技术的安全性、有效性和患者获益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Technique and Preliminary Results of Sole-echocardiography-guided Tricuspid Transcatheter Edge-to-edge Repair without the Use of Fluoroscopy.

Background: Tricuspid transcatheter edge-to-edge repair (T-TEER) has emerged as an attractive option for severe tricuspid regurgitation (TR). To avoid the radiation exposure for both patients and medical staff, we propose a sole-echocardiography-guided method for T-TEER. The purpose of this article was to investigate the feasibility of sole-echocardiography-guided T-TEER.

Methods: This was a retrospective observational study, including 43 patients who underwent sole-echocardiography-guided T-TEER at two medical centers in China between June 2022 and September 2023. Clinical and echocardiographic data were collected at baseline, discharge and 6-month follow-up.

Results: Patients enrolled in this study were elderly (71.6 ± 8.2 years) with significant comorbidities, 67.4% had baseline massive or torrential TR and 76.7% were classified as New York Heart Association (NYHA) functional class III/IV. All patients achieved successful device implantation, and no severe device-related complications or mortality occurred during the follow-up period. Significantly reduced TR and reversed right ventricular remodeling were observed at 6-month follow-ups. Patients classified as NYHA functional class I/II increased from 23.3% at baseline to 81.4% at 6-month follow-up (p < 0.001).

Conclusions: Sole-echocardiography-guided T-TEER has a low incidence of complications and can effectively reduce TR. It is feasible to substitute conventional fluoroscopy and echocardiography guidance for echocardiography guidance alone. Further large-scale randomized controlled trials are needed to validate the safety, efficacy and patient benefits of this technique.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Reviews in cardiovascular medicine
Reviews in cardiovascular medicine 医学-心血管系统
CiteScore
2.70
自引率
3.70%
发文量
377
审稿时长
1 months
期刊介绍: RCM is an international, peer-reviewed, open access journal. RCM publishes research articles, review papers and short communications on cardiovascular medicine as well as research on cardiovascular disease. We aim to provide a forum for publishing papers which explore the pathogenesis and promote the progression of cardiac and vascular diseases. We also seek to establish an interdisciplinary platform, focusing on translational issues, to facilitate the advancement of research, clinical treatment and diagnostic procedures. Heart surgery, cardiovascular imaging, risk factors and various clinical cardiac & vascular research will be considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信