{"title":"定制动力髋螺钉治疗股骨颈骨不连外翻截骨一例","authors":"Posatorn Suwanpongsai,&nbsp;Kongkhet Riansuwan","doi":"10.1016/j.tcr.2024.101119","DOIUrl":null,"url":null,"abstract":"<div><div>We report the treatment of femoral neck nonunion in an adult female who has remarkable femoral neck anatomy. The initial fracture was treated by closed reduction and multiple screws incorporated pin fixation. Eventually, nonunion with implant loosening developed after about 10 following months. Therefore, trochanteric valgus osteotomy and dynamic hip screw fixation was determined to treat the nonunion. As a result of implant-anatomy mismatching, the customized lag screw was designed to compromise both of the particular anatomy and the ordinary side plate. The implant was manufactured using a Computer Numerical Control (CNC) machine. Finally, the nonunion and osteotomy site completely healed without complication.</div></div>","PeriodicalId":23291,"journal":{"name":"Trauma Case Reports","volume":"54 ","pages":"Article 101119"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A customized dynamic hip screw for valgus osteotomy in femoral neck nonunion with remarkable anatomy: A case report\",\"authors\":\"Posatorn Suwanpongsai,&nbsp;Kongkhet Riansuwan\",\"doi\":\"10.1016/j.tcr.2024.101119\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>We report the treatment of femoral neck nonunion in an adult female who has remarkable femoral neck anatomy. The initial fracture was treated by closed reduction and multiple screws incorporated pin fixation. Eventually, nonunion with implant loosening developed after about 10 following months. Therefore, trochanteric valgus osteotomy and dynamic hip screw fixation was determined to treat the nonunion. As a result of implant-anatomy mismatching, the customized lag screw was designed to compromise both of the particular anatomy and the ordinary side plate. The implant was manufactured using a Computer Numerical Control (CNC) machine. Finally, the nonunion and osteotomy site completely healed without complication.</div></div>\",\"PeriodicalId\":23291,\"journal\":{\"name\":\"Trauma Case Reports\",\"volume\":\"54 \",\"pages\":\"Article 101119\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trauma Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352644024001420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352644024001420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

我们报告的治疗股骨颈骨不连在一个成年女性谁有显著的股骨颈解剖。最初的骨折采用闭合复位和多枚螺钉结合销固定治疗。最终,种植体松动的骨不连在10个月后出现。因此,我们决定采用转子外翻截骨和动力髋螺钉固定来治疗骨不连。由于种植体与解剖结构不匹配,定制的拉力螺钉被设计为折衷特殊解剖结构和普通侧板。种植体使用计算机数控(CNC)机器制造。最后,骨不连和截骨部位完全愈合,无并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A customized dynamic hip screw for valgus osteotomy in femoral neck nonunion with remarkable anatomy: A case report
We report the treatment of femoral neck nonunion in an adult female who has remarkable femoral neck anatomy. The initial fracture was treated by closed reduction and multiple screws incorporated pin fixation. Eventually, nonunion with implant loosening developed after about 10 following months. Therefore, trochanteric valgus osteotomy and dynamic hip screw fixation was determined to treat the nonunion. As a result of implant-anatomy mismatching, the customized lag screw was designed to compromise both of the particular anatomy and the ordinary side plate. The implant was manufactured using a Computer Numerical Control (CNC) machine. Finally, the nonunion and osteotomy site completely healed without complication.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Trauma Case Reports
Trauma Case Reports Medicine-Emergency Medicine
CiteScore
0.60
自引率
0.00%
发文量
131
审稿时长
26 weeks
期刊介绍: Trauma Case Reports is the only open access, online journal dedicated to the publication of case reports in all aspects of trauma care and accident surgery. Case reports on all aspects of trauma management, surgical procedures for all tissues, resuscitation, anaesthesia and trauma and tissue healing will be considered for publication by the international editorial team and will be subject to peer review. Bringing together these cases from an international authorship will shed light on surgical problems and help in their effective resolution.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信