{"title":"颞下颌关节关节镜培训模拟器的验证。","authors":"José Luis Moyano-Cuevas ,&nbsp;J. Blas Pagador ,&nbsp;Nadeem Saeed ,&nbsp;Francisco M. Sánchez-Margallo ,&nbsp;Florencio Monje-Gil","doi":"10.1016/j.jcms.2024.10.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>This study aims to evaluate a temporomandibular joint (TMJ) arthroscopy simulator using construct and face analyses.</div></div><div><h3>Methods</h3><div>Thirty participants attending a TMJ training course were divided into novice and expert surgeons (more than 100 procedures) and performed two arthroscopic tasks (cavity access/cavity exploration) during which the surgical tool movements were tracked. Five objective metrics were used to measure surgeon ability and construct validity was assessed by comparing novel and expert performance. Face validity was assessed by subjective questionnaires rating simulator realism and utility (1–5 scale) and tissue consistency (1–4 scale).</div></div><div><h3>Results</h3><div>Expert surgeons spent less <em>total time</em> (76.58 ± 47.40 vs. 27.60 ± 5.52; novices vs. experts) with higher <em>average speed</em> (7.40 ± 5.32 vs. 12.65 ± 5.37) and <em>average acceleration</em> (198.33 ± 2.42 vs. 325.93 ± 87.36). <em>Movement smoothness</em> revealed lower values in novice surgeons (3638.33 ± 1083.95 mm/s<sup>3</sup>; 2553.70 ± 768.01 mm/s<sup>3</sup>) than in expert surgeons (4655.63 ± 837.05 mm/s<sup>3</sup>; 4172.08 ± 1098.61 mm/s<sup>3</sup>). All these outcomes reached statistical significance (p ≤ 0.05) but in contrast <em>total path</em> of the instruments did not. Face validity scores averaged 4.75/5 for utility and over 4/5 for realism except for watertightness. Tissue consistency was regarded as lower than human tissue but without impact on the training experience. There were no statistically significant differences between the two groups.</div></div><div><h3>Conclusions</h3><div>Both the construct and face validity analyses confirmed the TMJ simulator can be regarded as a valuable, safe, economic adjunctive tool to train TMJ arthroscopy.</div></div>","PeriodicalId":54851,"journal":{"name":"Journal of Cranio-Maxillofacial Surgery","volume":"53 1","pages":"Pages 52-56"},"PeriodicalIF":2.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of a training simulator for temporomandibular joint arthroscopy\",\"authors\":\"José Luis Moyano-Cuevas ,&nbsp;J. Blas Pagador ,&nbsp;Nadeem Saeed ,&nbsp;Francisco M. Sánchez-Margallo ,&nbsp;Florencio Monje-Gil\",\"doi\":\"10.1016/j.jcms.2024.10.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><div>This study aims to evaluate a temporomandibular joint (TMJ) arthroscopy simulator using construct and face analyses.</div></div><div><h3>Methods</h3><div>Thirty participants attending a TMJ training course were divided into novice and expert surgeons (more than 100 procedures) and performed two arthroscopic tasks (cavity access/cavity exploration) during which the surgical tool movements were tracked. Five objective metrics were used to measure surgeon ability and construct validity was assessed by comparing novel and expert performance. Face validity was assessed by subjective questionnaires rating simulator realism and utility (1–5 scale) and tissue consistency (1–4 scale).</div></div><div><h3>Results</h3><div>Expert surgeons spent less <em>total time</em> (76.58 ± 47.40 vs. 27.60 ± 5.52; novices vs. experts) with higher <em>average speed</em> (7.40 ± 5.32 vs. 12.65 ± 5.37) and <em>average acceleration</em> (198.33 ± 2.42 vs. 325.93 ± 87.36). <em>Movement smoothness</em> revealed lower values in novice surgeons (3638.33 ± 1083.95 mm/s<sup>3</sup>; 2553.70 ± 768.01 mm/s<sup>3</sup>) than in expert surgeons (4655.63 ± 837.05 mm/s<sup>3</sup>; 4172.08 ± 1098.61 mm/s<sup>3</sup>). All these outcomes reached statistical significance (p ≤ 0.05) but in contrast <em>total path</em> of the instruments did not. Face validity scores averaged 4.75/5 for utility and over 4/5 for realism except for watertightness. Tissue consistency was regarded as lower than human tissue but without impact on the training experience. There were no statistically significant differences between the two groups.</div></div><div><h3>Conclusions</h3><div>Both the construct and face validity analyses confirmed the TMJ simulator can be regarded as a valuable, safe, economic adjunctive tool to train TMJ arthroscopy.</div></div>\",\"PeriodicalId\":54851,\"journal\":{\"name\":\"Journal of Cranio-Maxillofacial Surgery\",\"volume\":\"53 1\",\"pages\":\"Pages 52-56\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cranio-Maxillofacial Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1010518224002889\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cranio-Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1010518224002889","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的本研究旨在通过构造和面相分析对颞下颌关节(TMJ)关节镜模拟器进行评估:参加颞下颌关节培训课程的 30 名学员被分为新手和专家外科医生(超过 100 例手术),并执行了两项关节镜任务(腔入/腔探查),期间对手术工具的移动进行了跟踪。使用五个客观指标来衡量外科医生的能力,并通过比较新手和专家的表现来评估结构效度。通过主观问卷对模拟器的真实性和实用性(1-5 级)以及组织一致性(1-4 级)进行评估:结果:专家外科医生花费的总时间较少(76.58 ± 47.40 vs. 27.60 ± 5.52;新手 vs. 专家),平均速度(7.40 ± 5.32 vs. 12.65 ± 5.37)和平均加速度(198.33 ± 2.42 vs. 325.93 ± 87.36)较高。新手的运动平滑度值(3638.33 ± 1083.95 mm/s3;2553.70 ± 768.01 mm/s3)低于专家(4655.63 ± 837.05 mm/s3;4172.08 ± 1098.61 mm/s3)。所有这些结果均有统计学意义(p ≤ 0.05),但与此相反,工具的总路径却没有统计学意义。除水密性外,表面效度的实用性平均得分为 4.75/5,真实性平均得分为 4/5 以上。组织一致性被认为低于人体组织,但对培训体验没有影响。两组之间没有明显的统计学差异:颞下颌关节模拟器的结构效度和表面效度分析均证实,该模拟器可被视为培训颞下颌关节镜的一种有价值、安全、经济的辅助工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Validation of a training simulator for temporomandibular joint arthroscopy

Objective

This study aims to evaluate a temporomandibular joint (TMJ) arthroscopy simulator using construct and face analyses.

Methods

Thirty participants attending a TMJ training course were divided into novice and expert surgeons (more than 100 procedures) and performed two arthroscopic tasks (cavity access/cavity exploration) during which the surgical tool movements were tracked. Five objective metrics were used to measure surgeon ability and construct validity was assessed by comparing novel and expert performance. Face validity was assessed by subjective questionnaires rating simulator realism and utility (1–5 scale) and tissue consistency (1–4 scale).

Results

Expert surgeons spent less total time (76.58 ± 47.40 vs. 27.60 ± 5.52; novices vs. experts) with higher average speed (7.40 ± 5.32 vs. 12.65 ± 5.37) and average acceleration (198.33 ± 2.42 vs. 325.93 ± 87.36). Movement smoothness revealed lower values in novice surgeons (3638.33 ± 1083.95 mm/s3; 2553.70 ± 768.01 mm/s3) than in expert surgeons (4655.63 ± 837.05 mm/s3; 4172.08 ± 1098.61 mm/s3). All these outcomes reached statistical significance (p ≤ 0.05) but in contrast total path of the instruments did not. Face validity scores averaged 4.75/5 for utility and over 4/5 for realism except for watertightness. Tissue consistency was regarded as lower than human tissue but without impact on the training experience. There were no statistically significant differences between the two groups.

Conclusions

Both the construct and face validity analyses confirmed the TMJ simulator can be regarded as a valuable, safe, economic adjunctive tool to train TMJ arthroscopy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.20
自引率
22.60%
发文量
117
审稿时长
70 days
期刊介绍: The Journal of Cranio-Maxillofacial Surgery publishes articles covering all aspects of surgery of the head, face and jaw. Specific topics covered recently have included: • Distraction osteogenesis • Synthetic bone substitutes • Fibroblast growth factors • Fetal wound healing • Skull base surgery • Computer-assisted surgery • Vascularized bone grafts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信