开发和评估深度学习模型,以减少颌骨锥形束计算机断层扫描中与体外物质相关的金属伪影。

IF 2.9 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Matheus L Oliveira, Susanne Schaub, Dorothea Dagassan-Berndt, Florentin Bieder, Philippe C Cattin, Michael M Bornstein
{"title":"开发和评估深度学习模型,以减少颌骨锥形束计算机断层扫描中与体外物质相关的金属伪影。","authors":"Matheus L Oliveira, Susanne Schaub, Dorothea Dagassan-Berndt, Florentin Bieder, Philippe C Cattin, Michael M Bornstein","doi":"10.1093/dmfr/twae062","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To develop and evaluate a deep learning (DL) model to reduce metal artefacts originating from the exomass in cone-beam computed tomography (CBCT) of the jaws.</p><p><strong>Methods: </strong>Five porcine mandibles, each featuring six tubes filled with a radiopaque solution, were scanned using four CBCT units before and after the incremental insertion of up to three titanium, titanium-zirconium, and zirconia dental implants in the exomass of a small field of view. A conditional denoising diffusion probabilistic model, using DL techniques, was employed to correct images from exomass-related metal artefacts across the CBCT units and implant scenarios. Three examiners independently scored the image quality of all datasets, including those without an implant (ground truth), with implants in the exomass (original), and DL-generated ones. Quantitative analysis compared contrast-to-noise ratio (CNR) to validate artefact reduction using repeated measures analysis of variance in a factorial design followed by Tukey test (α = 0.05).</p><p><strong>Results: </strong>The visualisation of the hard tissues and overall image quality was reduced in the original and increased in the DL-generated images. The score variation observed in the original images was not observed in the DL-generated images, which generally scored higher than the original images. DL-generated images revealed significantly greater CNR than both the ground truth and their corresponding original images, regardless of the material and quantity of dental implants and the CBCT unit (p < 0.05). Original images revealed significantly lower CNR than the ground truth (p < 0.05).</p><p><strong>Conclusions: </strong>The developed DL model demonstrated promising performance in correcting exomass-related metal artefacts in CBCT of the jaws.</p>","PeriodicalId":11261,"journal":{"name":"Dento maxillo facial radiology","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Evaluation of a Deep Learning Model to Reduce Exomass-Related Metal Artefacts in Cone-Beam Computed Tomography of the Jaws.\",\"authors\":\"Matheus L Oliveira, Susanne Schaub, Dorothea Dagassan-Berndt, Florentin Bieder, Philippe C Cattin, Michael M Bornstein\",\"doi\":\"10.1093/dmfr/twae062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To develop and evaluate a deep learning (DL) model to reduce metal artefacts originating from the exomass in cone-beam computed tomography (CBCT) of the jaws.</p><p><strong>Methods: </strong>Five porcine mandibles, each featuring six tubes filled with a radiopaque solution, were scanned using four CBCT units before and after the incremental insertion of up to three titanium, titanium-zirconium, and zirconia dental implants in the exomass of a small field of view. A conditional denoising diffusion probabilistic model, using DL techniques, was employed to correct images from exomass-related metal artefacts across the CBCT units and implant scenarios. Three examiners independently scored the image quality of all datasets, including those without an implant (ground truth), with implants in the exomass (original), and DL-generated ones. Quantitative analysis compared contrast-to-noise ratio (CNR) to validate artefact reduction using repeated measures analysis of variance in a factorial design followed by Tukey test (α = 0.05).</p><p><strong>Results: </strong>The visualisation of the hard tissues and overall image quality was reduced in the original and increased in the DL-generated images. The score variation observed in the original images was not observed in the DL-generated images, which generally scored higher than the original images. DL-generated images revealed significantly greater CNR than both the ground truth and their corresponding original images, regardless of the material and quantity of dental implants and the CBCT unit (p < 0.05). Original images revealed significantly lower CNR than the ground truth (p < 0.05).</p><p><strong>Conclusions: </strong>The developed DL model demonstrated promising performance in correcting exomass-related metal artefacts in CBCT of the jaws.</p>\",\"PeriodicalId\":11261,\"journal\":{\"name\":\"Dento maxillo facial radiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dento maxillo facial radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/dmfr/twae062\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dento maxillo facial radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dmfr/twae062","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的开发并评估一种深度学习(DL)模型,以减少颌骨锥束计算机断层扫描(CBCT)中来自外质的金属伪影:使用四台 CBCT 设备对五头猪的下颌骨进行扫描,每头猪的下颌骨上都有六根充满不透射线溶液的管子,在小视场的外质中逐步植入最多三颗钛、钛锆和氧化锆牙科植入体之前和之后都进行了扫描。使用 DL 技术建立了条件去噪扩散概率模型,以校正 CBCT 设备和种植体情景中与外瘤相关的金属伪影图像。三名检查人员对所有数据集的图像质量进行了独立评分,包括没有植入物的数据集(地面实况)、有植入物的数据集(原始数据)和 DL 生成的数据集。定量分析比较了对比度-噪声比(CNR)以验证伪影的减少,采用因子设计的重复测量方差分析,然后进行 Tukey 检验(α = 0.05):在原始图像中,硬组织的可视化和整体图像质量有所降低,而在 DL 生成的图像中,可视化和整体图像质量有所提高。在原始图像中观察到的得分变化在 DL 生成的图像中没有观察到,DL 生成的图像得分普遍高于原始图像。无论牙科种植体的材料和数量以及 CBCT 设备如何,DL 生成的图像显示的 CNR 都明显高于地面实况和相应的原始图像(p 结论):开发的 DL 模型在纠正颌骨 CBCT 中与外生殖器相关的金属伪影方面表现良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development and Evaluation of a Deep Learning Model to Reduce Exomass-Related Metal Artefacts in Cone-Beam Computed Tomography of the Jaws.

Objectives: To develop and evaluate a deep learning (DL) model to reduce metal artefacts originating from the exomass in cone-beam computed tomography (CBCT) of the jaws.

Methods: Five porcine mandibles, each featuring six tubes filled with a radiopaque solution, were scanned using four CBCT units before and after the incremental insertion of up to three titanium, titanium-zirconium, and zirconia dental implants in the exomass of a small field of view. A conditional denoising diffusion probabilistic model, using DL techniques, was employed to correct images from exomass-related metal artefacts across the CBCT units and implant scenarios. Three examiners independently scored the image quality of all datasets, including those without an implant (ground truth), with implants in the exomass (original), and DL-generated ones. Quantitative analysis compared contrast-to-noise ratio (CNR) to validate artefact reduction using repeated measures analysis of variance in a factorial design followed by Tukey test (α = 0.05).

Results: The visualisation of the hard tissues and overall image quality was reduced in the original and increased in the DL-generated images. The score variation observed in the original images was not observed in the DL-generated images, which generally scored higher than the original images. DL-generated images revealed significantly greater CNR than both the ground truth and their corresponding original images, regardless of the material and quantity of dental implants and the CBCT unit (p < 0.05). Original images revealed significantly lower CNR than the ground truth (p < 0.05).

Conclusions: The developed DL model demonstrated promising performance in correcting exomass-related metal artefacts in CBCT of the jaws.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
9.10%
发文量
65
审稿时长
4-8 weeks
期刊介绍: Dentomaxillofacial Radiology (DMFR) is the journal of the International Association of Dentomaxillofacial Radiology (IADMFR) and covers the closely related fields of oral radiology and head and neck imaging. Established in 1972, DMFR is a key resource keeping dentists, radiologists and clinicians and scientists with an interest in Head and Neck imaging abreast of important research and developments in oral and maxillofacial radiology. The DMFR editorial board features a panel of international experts including Editor-in-Chief Professor Ralf Schulze. Our editorial board provide their expertise and guidance in shaping the content and direction of the journal. Quick Facts: - 2015 Impact Factor - 1.919 - Receipt to first decision - average of 3 weeks - Acceptance to online publication - average of 3 weeks - Open access option - ISSN: 0250-832X - eISSN: 1476-542X
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信