比较近红外成像技术和脉搏血氧仪在缺氧测试中的脑氧饱和度。

Q1 Medicine
Vasilios Alevizakos, Andreas Werner, Lisa-Marie Schiller, Constantin von See, Marcus Schiller
{"title":"比较近红外成像技术和脉搏血氧仪在缺氧测试中的脑氧饱和度。","authors":"Vasilios Alevizakos, Andreas Werner, Lisa-Marie Schiller, Constantin von See, Marcus Schiller","doi":"10.3390/medsci12040059","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> This study evaluates the suitability of cerebral oximetry using near-infrared spectroscopy (NIRS) compared to traditional pulse oximetry (SpO2) for measuring cerebral oxygen saturation during hypoxia testing, aiming to enhance safety during flight operations and training. <b>Material and Methods:</b> The study included 106 participants aged 18-60 years at the Aerospace Medicine Training Center in Königsbrück. Cerebral oxygen saturation (rSO2) and peripheral oxygen saturation (SpO2) were measured using the INVOS™ 5100C cerebral oximeter and Masimo™ MS5 pulse oximeter, respectively. Measurements were taken at baseline, during hypoxia at 25,000 feet, and post recovery. Data analysis included regression analysis, Bland-Altman plots, and concordance correlation coefficients (CCC). Ethical approval was obtained from the Hannover Medical School. Data from 100 participants were analyzed. <b>Results:</b> Baseline SpO2 was 97.5 ± 1.5%, and baseline rSO2 was 77.25 ± 6.4%. During hypoxia, SpO2 dropped significantly, while rSO2 showed higher values. SpO2 recovered faster than rSO2. Deviations in rSO2 between the right and left sides during hypoxia were minimal. Lin's CCC indicated moderate to substantial concordance. NIRS measurements were more stable and less prone to disturbances, with 95 disruptions in pulse oximetry, 25 of which were potentially critical. <b>Conclusions:</b> NIRS is a reliable method for detecting cerebral oxygen saturation, offering significant advantages over traditional pulse oximetry in stability and reliability during hypoxia testing. NIRS is less error-prone, supporting its use for continuous monitoring in aviation settings and enhancing flight safety by providing more accurate hypoxia detection.</p>","PeriodicalId":74152,"journal":{"name":"Medical sciences (Basel, Switzerland)","volume":"12 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11587096/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparing NIRS and Pulse Oximetry for Cerebral Oxygen Saturation During Hypoxia Testing.\",\"authors\":\"Vasilios Alevizakos, Andreas Werner, Lisa-Marie Schiller, Constantin von See, Marcus Schiller\",\"doi\":\"10.3390/medsci12040059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> This study evaluates the suitability of cerebral oximetry using near-infrared spectroscopy (NIRS) compared to traditional pulse oximetry (SpO2) for measuring cerebral oxygen saturation during hypoxia testing, aiming to enhance safety during flight operations and training. <b>Material and Methods:</b> The study included 106 participants aged 18-60 years at the Aerospace Medicine Training Center in Königsbrück. Cerebral oxygen saturation (rSO2) and peripheral oxygen saturation (SpO2) were measured using the INVOS™ 5100C cerebral oximeter and Masimo™ MS5 pulse oximeter, respectively. Measurements were taken at baseline, during hypoxia at 25,000 feet, and post recovery. Data analysis included regression analysis, Bland-Altman plots, and concordance correlation coefficients (CCC). Ethical approval was obtained from the Hannover Medical School. Data from 100 participants were analyzed. <b>Results:</b> Baseline SpO2 was 97.5 ± 1.5%, and baseline rSO2 was 77.25 ± 6.4%. During hypoxia, SpO2 dropped significantly, while rSO2 showed higher values. SpO2 recovered faster than rSO2. Deviations in rSO2 between the right and left sides during hypoxia were minimal. Lin's CCC indicated moderate to substantial concordance. NIRS measurements were more stable and less prone to disturbances, with 95 disruptions in pulse oximetry, 25 of which were potentially critical. <b>Conclusions:</b> NIRS is a reliable method for detecting cerebral oxygen saturation, offering significant advantages over traditional pulse oximetry in stability and reliability during hypoxia testing. NIRS is less error-prone, supporting its use for continuous monitoring in aviation settings and enhancing flight safety by providing more accurate hypoxia detection.</p>\",\"PeriodicalId\":74152,\"journal\":{\"name\":\"Medical sciences (Basel, Switzerland)\",\"volume\":\"12 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11587096/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical sciences (Basel, Switzerland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/medsci12040059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical sciences (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/medsci12040059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究评估了使用近红外光谱(NIRS)测量脑氧饱和度与传统脉搏血氧饱和度(SpO2)测量缺氧测试期间脑氧饱和度的适用性,旨在提高飞行操作和训练期间的安全性。材料与方法:研究对象包括 Königsbrück 航空医学培训中心 106 名 18-60 岁的学员。分别使用 INVOS™ 5100C 脑氧仪和 Masimo™ MS5 脉搏血氧仪测量脑氧饱和度 (rSO2) 和外周血氧饱和度 (SpO2)。测量分别在基线、25,000 英尺缺氧时和恢复后进行。数据分析包括回归分析、Bland-Altman 图和一致性相关系数 (CCC)。研究获得了汉诺威医学院的伦理批准。对 100 名参与者的数据进行了分析。结果基线 SpO2 为 97.5 ± 1.5%,基线 rSO2 为 77.25 ± 6.4%。缺氧时,SpO2 显著下降,而 rSO2 则显示较高值。SpO2 的恢复速度快于 rSO2。缺氧时左右两侧的 rSO2 偏差很小。Lin's CCC 显示中度到高度一致。NIRS 测量结果更稳定,不易受干扰,脉搏血氧仪有 95 次干扰,其中 25 次可能是严重干扰。结论近红外成像技术是一种检测脑氧饱和度的可靠方法,与传统的脉搏血氧仪相比,它在缺氧测试期间的稳定性和可靠性方面具有显著优势。近红外系统不易出错,可用于航空环境中的连续监测,并通过提供更准确的缺氧检测提高飞行安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparing NIRS and Pulse Oximetry for Cerebral Oxygen Saturation During Hypoxia Testing.

Objective: This study evaluates the suitability of cerebral oximetry using near-infrared spectroscopy (NIRS) compared to traditional pulse oximetry (SpO2) for measuring cerebral oxygen saturation during hypoxia testing, aiming to enhance safety during flight operations and training. Material and Methods: The study included 106 participants aged 18-60 years at the Aerospace Medicine Training Center in Königsbrück. Cerebral oxygen saturation (rSO2) and peripheral oxygen saturation (SpO2) were measured using the INVOS™ 5100C cerebral oximeter and Masimo™ MS5 pulse oximeter, respectively. Measurements were taken at baseline, during hypoxia at 25,000 feet, and post recovery. Data analysis included regression analysis, Bland-Altman plots, and concordance correlation coefficients (CCC). Ethical approval was obtained from the Hannover Medical School. Data from 100 participants were analyzed. Results: Baseline SpO2 was 97.5 ± 1.5%, and baseline rSO2 was 77.25 ± 6.4%. During hypoxia, SpO2 dropped significantly, while rSO2 showed higher values. SpO2 recovered faster than rSO2. Deviations in rSO2 between the right and left sides during hypoxia were minimal. Lin's CCC indicated moderate to substantial concordance. NIRS measurements were more stable and less prone to disturbances, with 95 disruptions in pulse oximetry, 25 of which were potentially critical. Conclusions: NIRS is a reliable method for detecting cerebral oxygen saturation, offering significant advantages over traditional pulse oximetry in stability and reliability during hypoxia testing. NIRS is less error-prone, supporting its use for continuous monitoring in aviation settings and enhancing flight safety by providing more accurate hypoxia detection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.00
自引率
0.00%
发文量
0
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信