{"title":"单对接机器人双侧腹横肌松解术:技术描述和初步结果。","authors":"Arturo Estrada, Jorge Humberto Rodriguez-Quintero, Luis Arias-Espinosa, Prashanth Sreeramoju, Fareed Cheema, Xavier Pereira, Flavio Malcher","doi":"10.1097/SLE.0000000000001346","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Posterior component separation with transversus abdominis release (TAR) is a valuable adjunct to address incisional hernia defects. Currently, bilateral docking is a standard technique for robotic TAR. The aim of this study is to describe our technique for extended totally extraperitoneal (eTEP) repair with bilateral TAR through a bottom single-dock robotic approach for hernias at the level of the umbilicus or higher.</p><p><strong>Materials and methods: </strong>We retrospectively reviewed a case series of patients who underwent robotic eTEP repair with bilateral TAR using a single bottom docking between November 2021 and November 2023. A comprehensive description of our patient selection, surgical technique, and short-term clinical outcomes is reported.</p><p><strong>Results: </strong>Ten patients with incisional hernias were included. Their median age was 55 years (IQR: 49.5 to 61.25), 70% were male, the median BMI was 27.25 kg/m (IQR: 22.95 to 33.53), and ASA class was ≥2 in 80%. Median hernia width was 10 cm (IQR: 6.75 to 12.25) and length 11 cm (IQR: 9.25 to 16.25). The median operative time was 178.5 minutes (IQR: 153.75 to 222), and the length of stay was 1 day (IQR: 0.75 to 1.75). At a median follow-up of 5 months (IQR: 2.6 to 9.7), 20% of patients developed a surgical site occurrence requiring procedural intervention.</p><p><strong>Conclusion: </strong>Bilateral TAR using a single bottom dock is a feasible and safe adjunct to robotic eTEP ventral hernia repair in appropriately selected patients.</p>","PeriodicalId":22092,"journal":{"name":"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-dock Robotic Bilateral Transversus Abdominis Release: Technique Description and Preliminary Outcomes.\",\"authors\":\"Arturo Estrada, Jorge Humberto Rodriguez-Quintero, Luis Arias-Espinosa, Prashanth Sreeramoju, Fareed Cheema, Xavier Pereira, Flavio Malcher\",\"doi\":\"10.1097/SLE.0000000000001346\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Posterior component separation with transversus abdominis release (TAR) is a valuable adjunct to address incisional hernia defects. Currently, bilateral docking is a standard technique for robotic TAR. The aim of this study is to describe our technique for extended totally extraperitoneal (eTEP) repair with bilateral TAR through a bottom single-dock robotic approach for hernias at the level of the umbilicus or higher.</p><p><strong>Materials and methods: </strong>We retrospectively reviewed a case series of patients who underwent robotic eTEP repair with bilateral TAR using a single bottom docking between November 2021 and November 2023. A comprehensive description of our patient selection, surgical technique, and short-term clinical outcomes is reported.</p><p><strong>Results: </strong>Ten patients with incisional hernias were included. Their median age was 55 years (IQR: 49.5 to 61.25), 70% were male, the median BMI was 27.25 kg/m (IQR: 22.95 to 33.53), and ASA class was ≥2 in 80%. Median hernia width was 10 cm (IQR: 6.75 to 12.25) and length 11 cm (IQR: 9.25 to 16.25). The median operative time was 178.5 minutes (IQR: 153.75 to 222), and the length of stay was 1 day (IQR: 0.75 to 1.75). At a median follow-up of 5 months (IQR: 2.6 to 9.7), 20% of patients developed a surgical site occurrence requiring procedural intervention.</p><p><strong>Conclusion: </strong>Bilateral TAR using a single bottom dock is a feasible and safe adjunct to robotic eTEP ventral hernia repair in appropriately selected patients.</p>\",\"PeriodicalId\":22092,\"journal\":{\"name\":\"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/SLE.0000000000001346\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SLE.0000000000001346","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
Background: Posterior component separation with transversus abdominis release (TAR) is a valuable adjunct to address incisional hernia defects. Currently, bilateral docking is a standard technique for robotic TAR. The aim of this study is to describe our technique for extended totally extraperitoneal (eTEP) repair with bilateral TAR through a bottom single-dock robotic approach for hernias at the level of the umbilicus or higher.
Materials and methods: We retrospectively reviewed a case series of patients who underwent robotic eTEP repair with bilateral TAR using a single bottom docking between November 2021 and November 2023. A comprehensive description of our patient selection, surgical technique, and short-term clinical outcomes is reported.
Results: Ten patients with incisional hernias were included. Their median age was 55 years (IQR: 49.5 to 61.25), 70% were male, the median BMI was 27.25 kg/m (IQR: 22.95 to 33.53), and ASA class was ≥2 in 80%. Median hernia width was 10 cm (IQR: 6.75 to 12.25) and length 11 cm (IQR: 9.25 to 16.25). The median operative time was 178.5 minutes (IQR: 153.75 to 222), and the length of stay was 1 day (IQR: 0.75 to 1.75). At a median follow-up of 5 months (IQR: 2.6 to 9.7), 20% of patients developed a surgical site occurrence requiring procedural intervention.
Conclusion: Bilateral TAR using a single bottom dock is a feasible and safe adjunct to robotic eTEP ventral hernia repair in appropriately selected patients.
期刊介绍:
Surgical Laparoscopy Endoscopy & Percutaneous Techniques is a primary source for peer-reviewed, original articles on the newest techniques and applications in operative laparoscopy and endoscopy. Its Editorial Board includes many of the surgeons who pioneered the use of these revolutionary techniques. The journal provides complete, timely, accurate, practical coverage of laparoscopic and endoscopic techniques and procedures; current clinical and basic science research; preoperative and postoperative patient management; complications in laparoscopic and endoscopic surgery; and new developments in instrumentation and technology.