用矩法进行高分辨率正电子寿命层析成像。

IF 3.3 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Bangyan Huang, Jinyi Qi
{"title":"用矩法进行高分辨率正电子寿命层析成像。","authors":"Bangyan Huang, Jinyi Qi","doi":"10.1088/1361-6560/ad9543","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Positronium lifetime tomography (PLT) is an emerging modality that aims to reconstruct 3D images of positronium lifetime in humans and animals<i>in vivo</i>. The lifetime of ortho-positronium can be influenced by the microstructure and the concentration of bio-active molecules in tissue, providing valuable information for better understanding disease progression and treatment response. However, efficient high-resolution lifetime image reconstruction methods are currently lacking. Existing methods are either computationally intensive or have poor spatial resolution. This paper presents a fast, high-resolution lifetime image reconstruction method for PLT.<i>Approach</i>. The proposed method, called SIMPLE-Moment (Statistical IMage reconstruction of Positron annihilation LifetimE by Moment weighting), first reconstructs a set of moment images and then estimates the ortho-positronium lifetime image using the method of moments. The implementation of SIMPLE-Moment requires minimal modification to the conventional ordered subset expectation maximization algorithm.<i>Main results.</i>With reasonable assumptions, the proposed method can reconstruct an ortho-positronium lifetime image with a computational cost equivalent to three standard positron emission tomography (PET) image reconstructions. A Monte Carlo simulation study based on an existing time-of-flight PET scanner demonstrates that the ortho-positronium lifetime image reconstructed by SIMPLE-Moment is accurate and comparable to results obtained using the more computationally intensive Statistical Positronium Lifetime Image reconstruction via time-Thresholding (SPLIT) method.<i>Significance</i>. The proposed SIMPLE-Moment method provides an efficient approach to high-resolution reconstruction of ortho-positronium lifetime images. By reducing computational costs while enhancing spatial resolution, this method has the potential to make PLT more accessible and practical for clinical and research applications.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11785412/pdf/","citationCount":"0","resultStr":"{\"title\":\"High-resolution positronium lifetime tomography by the method of moments.\",\"authors\":\"Bangyan Huang, Jinyi Qi\",\"doi\":\"10.1088/1361-6560/ad9543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective.</i>Positronium lifetime tomography (PLT) is an emerging modality that aims to reconstruct 3D images of positronium lifetime in humans and animals<i>in vivo</i>. The lifetime of ortho-positronium can be influenced by the microstructure and the concentration of bio-active molecules in tissue, providing valuable information for better understanding disease progression and treatment response. However, efficient high-resolution lifetime image reconstruction methods are currently lacking. Existing methods are either computationally intensive or have poor spatial resolution. This paper presents a fast, high-resolution lifetime image reconstruction method for PLT.<i>Approach</i>. The proposed method, called SIMPLE-Moment (Statistical IMage reconstruction of Positron annihilation LifetimE by Moment weighting), first reconstructs a set of moment images and then estimates the ortho-positronium lifetime image using the method of moments. The implementation of SIMPLE-Moment requires minimal modification to the conventional ordered subset expectation maximization algorithm.<i>Main results.</i>With reasonable assumptions, the proposed method can reconstruct an ortho-positronium lifetime image with a computational cost equivalent to three standard positron emission tomography (PET) image reconstructions. A Monte Carlo simulation study based on an existing time-of-flight PET scanner demonstrates that the ortho-positronium lifetime image reconstructed by SIMPLE-Moment is accurate and comparable to results obtained using the more computationally intensive Statistical Positronium Lifetime Image reconstruction via time-Thresholding (SPLIT) method.<i>Significance</i>. The proposed SIMPLE-Moment method provides an efficient approach to high-resolution reconstruction of ortho-positronium lifetime images. By reducing computational costs while enhancing spatial resolution, this method has the potential to make PLT more accessible and practical for clinical and research applications.</p>\",\"PeriodicalId\":20185,\"journal\":{\"name\":\"Physics in medicine and biology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11785412/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physics in medicine and biology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6560/ad9543\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ad9543","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:正电子寿命断层成像(PLT)是一种新兴模式,旨在重建人体和动物体内正电子寿命的三维图像。正电子寿命会受到组织中微观结构和生物活性分子浓度的影响,为更好地了解疾病进展和治疗反应提供了宝贵的信息。然而,目前还缺乏高效的高分辨率寿命图像重建方法。现有方法要么计算量大,要么空间分辨率低。本文提出了一种用于正电子寿命层析成像的快速、高分辨率寿命图像重建方法:所提出的方法称为 SIMPLE-Moment(通过矩加权法重建正电子湮灭寿命的统计图像),首先重建一组矩图像,然后使用矩方法估计正电子寿命图像。SIMPLE-Moment 的实现只需对传统的有序子集期望最大化(OSEM)算法进行最小限度的修改:在合理的假设条件下,所提出的方法可以重建正交正电子寿命图像,其计算成本相当于三个标准 PET 图像重建。基于现有飞行时间(TOF)正电子发射计算机扫描仪的蒙特卡罗模拟研究表明,SIMPLE-Moment 重建的正电子钋寿命图像是精确的,可与使用计算量更大的 SPLIT 方法重建的结果相媲美:所提出的 SIMPLE-Moment 方法为高分辨率重建正交钋寿命图像提供了一种有效的方法。这种方法在提高空间分辨率的同时降低了计算成本,有望使正电子寿命层析成像在临床和研究应用中更加方便实用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High-resolution positronium lifetime tomography by the method of moments.

Objective.Positronium lifetime tomography (PLT) is an emerging modality that aims to reconstruct 3D images of positronium lifetime in humans and animalsin vivo. The lifetime of ortho-positronium can be influenced by the microstructure and the concentration of bio-active molecules in tissue, providing valuable information for better understanding disease progression and treatment response. However, efficient high-resolution lifetime image reconstruction methods are currently lacking. Existing methods are either computationally intensive or have poor spatial resolution. This paper presents a fast, high-resolution lifetime image reconstruction method for PLT.Approach. The proposed method, called SIMPLE-Moment (Statistical IMage reconstruction of Positron annihilation LifetimE by Moment weighting), first reconstructs a set of moment images and then estimates the ortho-positronium lifetime image using the method of moments. The implementation of SIMPLE-Moment requires minimal modification to the conventional ordered subset expectation maximization algorithm.Main results.With reasonable assumptions, the proposed method can reconstruct an ortho-positronium lifetime image with a computational cost equivalent to three standard positron emission tomography (PET) image reconstructions. A Monte Carlo simulation study based on an existing time-of-flight PET scanner demonstrates that the ortho-positronium lifetime image reconstructed by SIMPLE-Moment is accurate and comparable to results obtained using the more computationally intensive Statistical Positronium Lifetime Image reconstruction via time-Thresholding (SPLIT) method.Significance. The proposed SIMPLE-Moment method provides an efficient approach to high-resolution reconstruction of ortho-positronium lifetime images. By reducing computational costs while enhancing spatial resolution, this method has the potential to make PLT more accessible and practical for clinical and research applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信