Dawon Jang, Jaeil Kim, Youngwon Jo, Hyuna Lee, Ahra Go, Jieun Kim, Soyoung Choi
{"title":"用信噪比替代抗药抗体滴度的可能性和局限性:使用阿达木单抗的两个临床试验数据集进行综合比较。","authors":"Dawon Jang, Jaeil Kim, Youngwon Jo, Hyuna Lee, Ahra Go, Jieun Kim, Soyoung Choi","doi":"10.1208/s12248-024-00991-x","DOIUrl":null,"url":null,"abstract":"<p><p>Immunogenicity assessment is vital in clinical trials and is measured through a multi-tiered approach (screening, confirmatory and titer assays). However, recent studies have suggested that titer results could be reported from ADA signal-to-noise ratios (S/N ratios=sample mean signal/negative control mean signal). More data analysis using two clinical trials of adalimumab: SB5-1003 (single-dose, healthy participants) and SB5-4001 (multiple-dose, interchangeability study, patients with plaque psoriasis), therefore, is indispensable whether substituting ADA S/N ratio as an alternative way of reporting titer results has no impact on interpretation on clinical outcome. In this study, we demonstrated that there is a strong correlation between S/N ratios and titers and no impact on overall PK results. Nonetheless, sub-analyses with time or adalimumab level showed a change in the regression between S/N ratios and titers, leading to different titer values from the same S/N ratio. These data demonstrate that S/N ratios may fully replace titers in limited circumstances such as a biosimilar study which goal is to prove equivalence between the originator and candidate product, but need a caution in other cases.</p>","PeriodicalId":50934,"journal":{"name":"AAPS Journal","volume":"27 1","pages":"3"},"PeriodicalIF":5.0000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Possibilities and Limitations in Substituting anti-Drug Antibody Titers with Signal-to-Noise Ratios: A Comprehensive Comparison Using Two Clinical Trial Datasets of Adalimumab.\",\"authors\":\"Dawon Jang, Jaeil Kim, Youngwon Jo, Hyuna Lee, Ahra Go, Jieun Kim, Soyoung Choi\",\"doi\":\"10.1208/s12248-024-00991-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Immunogenicity assessment is vital in clinical trials and is measured through a multi-tiered approach (screening, confirmatory and titer assays). However, recent studies have suggested that titer results could be reported from ADA signal-to-noise ratios (S/N ratios=sample mean signal/negative control mean signal). More data analysis using two clinical trials of adalimumab: SB5-1003 (single-dose, healthy participants) and SB5-4001 (multiple-dose, interchangeability study, patients with plaque psoriasis), therefore, is indispensable whether substituting ADA S/N ratio as an alternative way of reporting titer results has no impact on interpretation on clinical outcome. In this study, we demonstrated that there is a strong correlation between S/N ratios and titers and no impact on overall PK results. Nonetheless, sub-analyses with time or adalimumab level showed a change in the regression between S/N ratios and titers, leading to different titer values from the same S/N ratio. These data demonstrate that S/N ratios may fully replace titers in limited circumstances such as a biosimilar study which goal is to prove equivalence between the originator and candidate product, but need a caution in other cases.</p>\",\"PeriodicalId\":50934,\"journal\":{\"name\":\"AAPS Journal\",\"volume\":\"27 1\",\"pages\":\"3\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AAPS Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1208/s12248-024-00991-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AAPS Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1208/s12248-024-00991-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
摘要
免疫原性评估在临床试验中至关重要,并通过多层次方法(筛选、确证和滴度测定)进行测量。不过,最近的研究表明,滴度结果可以通过 ADA 信噪比(信噪比=样本平均信号/阴性对照平均信号)来报告。利用阿达木单抗的两项临床试验进行了更多数据分析:SB5-1003(单剂量,健康参与者)和 SB5-4001(多剂量,互换性研究,斑块状银屑病患者),因此,用 ADA 信噪比替代滴度结果作为报告滴度结果的替代方法是否对临床结果的解释没有影响,是不可或缺的。在这项研究中,我们证明了 S/N 比值与滴度之间有很强的相关性,对总体 PK 结果没有影响。然而,根据时间或阿达木单抗水平进行的子分析表明,S/N 比值与滴度之间的回归关系发生了变化,导致相同的 S/N 比值产生了不同的滴度值。这些数据表明,在有限的情况下,如以证明原研产品和候选产品之间等效性为目标的生物仿制药研究,信噪比可完全取代滴度,但在其他情况下则需谨慎。
Possibilities and Limitations in Substituting anti-Drug Antibody Titers with Signal-to-Noise Ratios: A Comprehensive Comparison Using Two Clinical Trial Datasets of Adalimumab.
Immunogenicity assessment is vital in clinical trials and is measured through a multi-tiered approach (screening, confirmatory and titer assays). However, recent studies have suggested that titer results could be reported from ADA signal-to-noise ratios (S/N ratios=sample mean signal/negative control mean signal). More data analysis using two clinical trials of adalimumab: SB5-1003 (single-dose, healthy participants) and SB5-4001 (multiple-dose, interchangeability study, patients with plaque psoriasis), therefore, is indispensable whether substituting ADA S/N ratio as an alternative way of reporting titer results has no impact on interpretation on clinical outcome. In this study, we demonstrated that there is a strong correlation between S/N ratios and titers and no impact on overall PK results. Nonetheless, sub-analyses with time or adalimumab level showed a change in the regression between S/N ratios and titers, leading to different titer values from the same S/N ratio. These data demonstrate that S/N ratios may fully replace titers in limited circumstances such as a biosimilar study which goal is to prove equivalence between the originator and candidate product, but need a caution in other cases.
期刊介绍:
The AAPS Journal, an official journal of the American Association of Pharmaceutical Scientists (AAPS), publishes novel and significant findings in the various areas of pharmaceutical sciences impacting human and veterinary therapeutics, including:
· Drug Design and Discovery
· Pharmaceutical Biotechnology
· Biopharmaceutics, Formulation, and Drug Delivery
· Metabolism and Transport
· Pharmacokinetics, Pharmacodynamics, and Pharmacometrics
· Translational Research
· Clinical Evaluations and Therapeutic Outcomes
· Regulatory Science
We invite submissions under the following article types:
· Original Research Articles
· Reviews and Mini-reviews
· White Papers, Commentaries, and Editorials
· Meeting Reports
· Brief/Technical Reports and Rapid Communications
· Regulatory Notes
· Tutorials
· Protocols in the Pharmaceutical Sciences
In addition, The AAPS Journal publishes themes, organized by guest editors, which are focused on particular areas of current interest to our field.