感音神经性听力损伤潜在早期标志物的受试者内变异。

IF 2.1 2区 物理与天体物理 Q2 ACOUSTICS
Nele De Poortere, Sarineh Keshishzadeh, Hannah Keppler, Ingeborg Dhooge, Sarah Verhulst
{"title":"感音神经性听力损伤潜在早期标志物的受试者内变异。","authors":"Nele De Poortere, Sarineh Keshishzadeh, Hannah Keppler, Ingeborg Dhooge, Sarah Verhulst","doi":"10.1121/10.0034423","DOIUrl":null,"url":null,"abstract":"<p><p>The quest for noninvasive early markers for sensorineural hearing loss (SNHL) has yielded diverse measures of interest. However, comprehensive studies evaluating the test-retest reliability of multiple measures and stimuli within a single study are scarce, and a standardized clinical protocol for robust early markers of SNHL remains elusive. To address these gaps, this study explores the intra-subject variability of various potential electroencephalogram- (EEG-) biomarkers for cochlear synaptopathy (CS) and other SNHL-markers in the same individuals. Fifteen normal-hearing young adults underwent repeated measures of (extended high-frequency) pure-tone audiometry, speech-in-noise intelligibility, distortion-product otoacoustic emissions (DPOAEs), and auditory evoked potentials; comprising envelope following responses (EFR) and auditory brainstem responses (ABR). Results confirm high reliability in pure-tone audiometry, whereas the matrix sentence-test exhibited a significant learning effect. The reliability of DPOAEs varied across three evaluation methods, each employing distinct SNR-based criteria for DPOAE-datapoints. EFRs exhibited superior test-retest reliability compared to ABR-amplitudes. Our findings emphasize the need for careful interpretation of presumed noninvasive SNHL measures. While tonal-audiometry's robustness was corroborated, we observed a confounding learning effect in longitudinal speech audiometry. The variability in DPOAEs highlights the importance of consistent ear probe replacement and meticulous measurement techniques, indicating that DPOAE test-retest reliability is significantly compromised under less-than-ideal conditions. As potential EEG-biomarkers of CS, EFRs are preferred over ABR-amplitudes based on the current study results.</p>","PeriodicalId":17168,"journal":{"name":"Journal of the Acoustical Society of America","volume":"156 5","pages":"3480-3495"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intrasubject variability in potential early markers of sensorineural hearing damage.\",\"authors\":\"Nele De Poortere, Sarineh Keshishzadeh, Hannah Keppler, Ingeborg Dhooge, Sarah Verhulst\",\"doi\":\"10.1121/10.0034423\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The quest for noninvasive early markers for sensorineural hearing loss (SNHL) has yielded diverse measures of interest. However, comprehensive studies evaluating the test-retest reliability of multiple measures and stimuli within a single study are scarce, and a standardized clinical protocol for robust early markers of SNHL remains elusive. To address these gaps, this study explores the intra-subject variability of various potential electroencephalogram- (EEG-) biomarkers for cochlear synaptopathy (CS) and other SNHL-markers in the same individuals. Fifteen normal-hearing young adults underwent repeated measures of (extended high-frequency) pure-tone audiometry, speech-in-noise intelligibility, distortion-product otoacoustic emissions (DPOAEs), and auditory evoked potentials; comprising envelope following responses (EFR) and auditory brainstem responses (ABR). Results confirm high reliability in pure-tone audiometry, whereas the matrix sentence-test exhibited a significant learning effect. The reliability of DPOAEs varied across three evaluation methods, each employing distinct SNR-based criteria for DPOAE-datapoints. EFRs exhibited superior test-retest reliability compared to ABR-amplitudes. Our findings emphasize the need for careful interpretation of presumed noninvasive SNHL measures. While tonal-audiometry's robustness was corroborated, we observed a confounding learning effect in longitudinal speech audiometry. The variability in DPOAEs highlights the importance of consistent ear probe replacement and meticulous measurement techniques, indicating that DPOAE test-retest reliability is significantly compromised under less-than-ideal conditions. As potential EEG-biomarkers of CS, EFRs are preferred over ABR-amplitudes based on the current study results.</p>\",\"PeriodicalId\":17168,\"journal\":{\"name\":\"Journal of the Acoustical Society of America\",\"volume\":\"156 5\",\"pages\":\"3480-3495\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Acoustical Society of America\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1121/10.0034423\",\"RegionNum\":2,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Acoustical Society of America","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1121/10.0034423","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

在寻找感音神经性听力损失(SNHL)的非侵入性早期标志物的过程中,人们发现了多种令人感兴趣的测量方法。然而,在一项研究中评估多种测量方法和刺激的测试-再测可靠性的综合研究并不多见,而且,对于 SNHL 的可靠早期标志物的标准化临床方案仍未确定。为了填补这些空白,本研究探讨了耳蜗突触病(CS)的各种潜在脑电图(EEG)生物标志物和其他 SNHL 标志物在同一受试者体内的变异性。15 名听力正常的年轻成年人接受了(扩展高频)纯音测听、噪声中语言清晰度、失真产物耳声发射(DPOAE)和听觉诱发电位的重复测量;包括包络跟随反应(EFR)和听觉脑干反应(ABR)。结果证实,纯音测听的可靠性很高,而矩阵句子测试则表现出明显的学习效应。三种评估方法的 DPOAE 可靠性各不相同,每种方法都采用不同的基于信噪比的 DPOAE 数据点标准。与 ABR 波幅相比,EFR 表现出更高的测试重复可靠性。我们的研究结果强调了对假定的非侵入性 SNHL 测量方法进行仔细解释的必要性。虽然音调测听的稳健性得到了证实,但我们在纵向言语测听中观察到了学习效应的干扰。DPOAEs 的变异性凸显了坚持更换耳探头和采用细致测量技术的重要性,这表明在不理想的条件下,DPOAE 的重复测试可靠性会大打折扣。根据目前的研究结果,作为 CS 的潜在脑电图生物标志物,EFR 比 ABR 振幅更受青睐。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intrasubject variability in potential early markers of sensorineural hearing damage.

The quest for noninvasive early markers for sensorineural hearing loss (SNHL) has yielded diverse measures of interest. However, comprehensive studies evaluating the test-retest reliability of multiple measures and stimuli within a single study are scarce, and a standardized clinical protocol for robust early markers of SNHL remains elusive. To address these gaps, this study explores the intra-subject variability of various potential electroencephalogram- (EEG-) biomarkers for cochlear synaptopathy (CS) and other SNHL-markers in the same individuals. Fifteen normal-hearing young adults underwent repeated measures of (extended high-frequency) pure-tone audiometry, speech-in-noise intelligibility, distortion-product otoacoustic emissions (DPOAEs), and auditory evoked potentials; comprising envelope following responses (EFR) and auditory brainstem responses (ABR). Results confirm high reliability in pure-tone audiometry, whereas the matrix sentence-test exhibited a significant learning effect. The reliability of DPOAEs varied across three evaluation methods, each employing distinct SNR-based criteria for DPOAE-datapoints. EFRs exhibited superior test-retest reliability compared to ABR-amplitudes. Our findings emphasize the need for careful interpretation of presumed noninvasive SNHL measures. While tonal-audiometry's robustness was corroborated, we observed a confounding learning effect in longitudinal speech audiometry. The variability in DPOAEs highlights the importance of consistent ear probe replacement and meticulous measurement techniques, indicating that DPOAE test-retest reliability is significantly compromised under less-than-ideal conditions. As potential EEG-biomarkers of CS, EFRs are preferred over ABR-amplitudes based on the current study results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
16.70%
发文量
1433
审稿时长
4.7 months
期刊介绍: Since 1929 The Journal of the Acoustical Society of America has been the leading source of theoretical and experimental research results in the broad interdisciplinary study of sound. Subject coverage includes: linear and nonlinear acoustics; aeroacoustics, underwater sound and acoustical oceanography; ultrasonics and quantum acoustics; architectural and structural acoustics and vibration; speech, music and noise; psychology and physiology of hearing; engineering acoustics, transduction; bioacoustics, animal bioacoustics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信