NOL Nociception Level Index® 监测系统在黑人和多种族人群中的初步验证。

IF 1.3 Q4 ENGINEERING, BIOMEDICAL
Medical Devices-Evidence and Research Pub Date : 2024-11-13 eCollection Date: 2024-01-01 DOI:10.2147/MDER.S492561
Rachel Weissbrod, Charlene Blake
{"title":"NOL Nociception Level Index® 监测系统在黑人和多种族人群中的初步验证。","authors":"Rachel Weissbrod, Charlene Blake","doi":"10.2147/MDER.S492561","DOIUrl":null,"url":null,"abstract":"<p><p>The NOL-Nociception Level Index<sup>®</sup> is a multiparameter index, based on artificial intelligence for the monitoring of nociception (physiological pain response) during anesthesia that has recently been authorized by the FDA. The monitor utilizes continuous streams of information from a finger probe comprising four sensors, including photoplethysmography, to provide a personalized nociception score on a scale of 0-100. Recent studies have suggested racial bias in pulse oximeter measurements due to the effect of melanin levels on photoplethysmography measurements. Therefore, there is a need to clinically validate new monitoring technologies in patients of all skin tones. The performance of the NOL scale in 8 patients that self-identified as Black or multiracial was compared to a database of 447 consented patients, assessing the response to surgical events at different levels of intensity. The descriptive, pilot data suggest that NOL performance in Black and multiracial patients is not different from the performance shown for the large database. Larger studies utilizing recognized skin tone scales to ensure accurate assessment of skin pigmentation are planned for the future.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":"17 ","pages":"465-469"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11570531/pdf/","citationCount":"0","resultStr":"{\"title\":\"Initial Validation of the NOL Nociception Level Index<sup>®</sup> Monitoring System in Black and Multiracial People.\",\"authors\":\"Rachel Weissbrod, Charlene Blake\",\"doi\":\"10.2147/MDER.S492561\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The NOL-Nociception Level Index<sup>®</sup> is a multiparameter index, based on artificial intelligence for the monitoring of nociception (physiological pain response) during anesthesia that has recently been authorized by the FDA. The monitor utilizes continuous streams of information from a finger probe comprising four sensors, including photoplethysmography, to provide a personalized nociception score on a scale of 0-100. Recent studies have suggested racial bias in pulse oximeter measurements due to the effect of melanin levels on photoplethysmography measurements. Therefore, there is a need to clinically validate new monitoring technologies in patients of all skin tones. The performance of the NOL scale in 8 patients that self-identified as Black or multiracial was compared to a database of 447 consented patients, assessing the response to surgical events at different levels of intensity. The descriptive, pilot data suggest that NOL performance in Black and multiracial patients is not different from the performance shown for the large database. Larger studies utilizing recognized skin tone scales to ensure accurate assessment of skin pigmentation are planned for the future.</p>\",\"PeriodicalId\":47140,\"journal\":{\"name\":\"Medical Devices-Evidence and Research\",\"volume\":\"17 \",\"pages\":\"465-469\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11570531/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Devices-Evidence and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/MDER.S492561\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S492561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

NOL-Nociception Level Index® 是一种基于人工智能的多参数指数,用于监测麻醉过程中的痛觉(生理疼痛反应),最近已获得美国食品及药物管理局的授权。该监测仪利用由四个传感器组成的手指探针(包括光电搏动监测仪)发出的连续信息流,提供 0-100 分的个性化痛觉评分。最近的研究表明,由于黑色素水平对光脉搏血氧仪测量值的影响,脉搏血氧仪测量值存在种族偏差。因此,有必要在各种肤色的患者中对新的监测技术进行临床验证。我们将 NOL 量表在 8 名自称为黑人或多种族的患者中的表现与 447 名获得同意的患者的数据库进行了比较,评估了不同强度的手术事件的反应。描述性试验数据表明,黑人和多种族患者的 NOL 表现与大型数据库显示的表现并无不同。未来计划进行更大规模的研究,利用公认的肤色量表确保准确评估皮肤色素沉着。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Initial Validation of the NOL Nociception Level Index® Monitoring System in Black and Multiracial People.

The NOL-Nociception Level Index® is a multiparameter index, based on artificial intelligence for the monitoring of nociception (physiological pain response) during anesthesia that has recently been authorized by the FDA. The monitor utilizes continuous streams of information from a finger probe comprising four sensors, including photoplethysmography, to provide a personalized nociception score on a scale of 0-100. Recent studies have suggested racial bias in pulse oximeter measurements due to the effect of melanin levels on photoplethysmography measurements. Therefore, there is a need to clinically validate new monitoring technologies in patients of all skin tones. The performance of the NOL scale in 8 patients that self-identified as Black or multiracial was compared to a database of 447 consented patients, assessing the response to surgical events at different levels of intensity. The descriptive, pilot data suggest that NOL performance in Black and multiracial patients is not different from the performance shown for the large database. Larger studies utilizing recognized skin tone scales to ensure accurate assessment of skin pigmentation are planned for the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信