{"title":"机器人宫颈肌瘤切除术:如何预防陷阱","authors":"K Ha , Soto D Encalada , E Mikhail","doi":"10.1016/j.jmig.2024.09.065","DOIUrl":null,"url":null,"abstract":"<div><h3>Study Objective</h3><div>The objective of this video is to present a simplified approach for robotic-assisted laparoscopic removal of cervical fibroids.</div></div><div><h3>Design</h3><div>Surgical video.</div></div><div><h3>Setting</h3><div>Tertiary care academic center.</div></div><div><h3>Patients or Participants</h3><div>32-year-old G0 with an 8 cm cervical fibroid.</div></div><div><h3>Interventions</h3><div>Robotic-assisted laparoscopic cervical myomectomy.</div></div><div><h3>Measurements and Main Results</h3><div>Patient underwent a robotic cervical myomectomy without complications. Estimated blood loss was 100 cc. The postoperative course was uncomplicated and the patient was discharged home in stable condition on postoperative day 1.</div></div><div><h3>Conclusion</h3><div>Complications of robotic cervical myomectomy can be minimized with the utilization of techniques such as ureteral stenting with indocyanine green injection, injection of the myoma with vasopressin, use of a tenaculum for myoma manipulation, and multi-layer myometrial closure.</div></div>","PeriodicalId":16397,"journal":{"name":"Journal of minimally invasive gynecology","volume":"31 11","pages":"Page S7"},"PeriodicalIF":3.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Robotic Cervical Myomectomy: How to Prevent Pitfalls\",\"authors\":\"K Ha , Soto D Encalada , E Mikhail\",\"doi\":\"10.1016/j.jmig.2024.09.065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Study Objective</h3><div>The objective of this video is to present a simplified approach for robotic-assisted laparoscopic removal of cervical fibroids.</div></div><div><h3>Design</h3><div>Surgical video.</div></div><div><h3>Setting</h3><div>Tertiary care academic center.</div></div><div><h3>Patients or Participants</h3><div>32-year-old G0 with an 8 cm cervical fibroid.</div></div><div><h3>Interventions</h3><div>Robotic-assisted laparoscopic cervical myomectomy.</div></div><div><h3>Measurements and Main Results</h3><div>Patient underwent a robotic cervical myomectomy without complications. Estimated blood loss was 100 cc. The postoperative course was uncomplicated and the patient was discharged home in stable condition on postoperative day 1.</div></div><div><h3>Conclusion</h3><div>Complications of robotic cervical myomectomy can be minimized with the utilization of techniques such as ureteral stenting with indocyanine green injection, injection of the myoma with vasopressin, use of a tenaculum for myoma manipulation, and multi-layer myometrial closure.</div></div>\",\"PeriodicalId\":16397,\"journal\":{\"name\":\"Journal of minimally invasive gynecology\",\"volume\":\"31 11\",\"pages\":\"Page S7\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of minimally invasive gynecology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1553465024004734\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of minimally invasive gynecology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1553465024004734","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
Patient underwent a robotic cervical myomectomy without complications. Estimated blood loss was 100 cc. The postoperative course was uncomplicated and the patient was discharged home in stable condition on postoperative day 1.
Conclusion
Complications of robotic cervical myomectomy can be minimized with the utilization of techniques such as ureteral stenting with indocyanine green injection, injection of the myoma with vasopressin, use of a tenaculum for myoma manipulation, and multi-layer myometrial closure.
期刊介绍:
The Journal of Minimally Invasive Gynecology, formerly titled The Journal of the American Association of Gynecologic Laparoscopists, is an international clinical forum for the exchange and dissemination of ideas, findings and techniques relevant to gynecologic endoscopy and other minimally invasive procedures. The Journal, which presents research, clinical opinions and case reports from the brightest minds in gynecologic surgery, is an authoritative source informing practicing physicians of the latest, cutting-edge developments occurring in this emerging field.