{"title":"自动触发防坍塌熔断硬件的性能研究及其在导体断裂输电线路上的应用","authors":"Jia-Xiang Li, Chao Zhang, Xing Fu, Jian Sun, Wen-Qiang Jiang, Biao Wang, Chun-Xu Qu","doi":"10.1155/2024/5031682","DOIUrl":null,"url":null,"abstract":"<div>\n <p>Conductor breakage with ice load is one of the major threats to the safe operation of transmission lines. The ice load increases the unbalanced longitudinal tension, leading to failure of tower members and even progressive collapse of the transmission line. This paper proposes an autotriggered anticollapse fusing hardware (AAFH), designed to reduce the unbalanced longitudinal tension caused by conductor breakage. When the longitudinal unbalanced tension of the transmission line exceeds the threshold of the AAFH, the fused part is destroyed, and the AAFH is elongated to reduce the longitudinal unbalanced tension. First, the construction and working mechanism of the device are introduced, and a numerical model of the transmission line–AAFH system is established to verify its effectiveness. Then, a parameter determination method for unbalanced tension in the tower-line system subjected to conductor breakage is proposed. In addition, the control performance of the device is studied. The results show that AAFH can effectively reduce the unbalanced tension induced by conductor breakage. The proposed method can predict the unbalanced tension of transmission lines, with an error within 10%. The greater the length of vertical/horizontal elongation, the better the protective effect. From a safety perspective, the AAFH should be designed according to the actual transmission line parameters to achieve an ideal control effect.</p>\n </div>","PeriodicalId":49471,"journal":{"name":"Structural Control & Health Monitoring","volume":"2024 1","pages":""},"PeriodicalIF":4.6000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/5031682","citationCount":"0","resultStr":"{\"title\":\"Performance Study of an Autotriggered Anticollapse Fusing Hardware and Its Application on Transmission Lines Subjected to Conductor Breakage\",\"authors\":\"Jia-Xiang Li, Chao Zhang, Xing Fu, Jian Sun, Wen-Qiang Jiang, Biao Wang, Chun-Xu Qu\",\"doi\":\"10.1155/2024/5031682\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n <p>Conductor breakage with ice load is one of the major threats to the safe operation of transmission lines. The ice load increases the unbalanced longitudinal tension, leading to failure of tower members and even progressive collapse of the transmission line. This paper proposes an autotriggered anticollapse fusing hardware (AAFH), designed to reduce the unbalanced longitudinal tension caused by conductor breakage. When the longitudinal unbalanced tension of the transmission line exceeds the threshold of the AAFH, the fused part is destroyed, and the AAFH is elongated to reduce the longitudinal unbalanced tension. First, the construction and working mechanism of the device are introduced, and a numerical model of the transmission line–AAFH system is established to verify its effectiveness. Then, a parameter determination method for unbalanced tension in the tower-line system subjected to conductor breakage is proposed. In addition, the control performance of the device is studied. The results show that AAFH can effectively reduce the unbalanced tension induced by conductor breakage. The proposed method can predict the unbalanced tension of transmission lines, with an error within 10%. The greater the length of vertical/horizontal elongation, the better the protective effect. From a safety perspective, the AAFH should be designed according to the actual transmission line parameters to achieve an ideal control effect.</p>\\n </div>\",\"PeriodicalId\":49471,\"journal\":{\"name\":\"Structural Control & Health Monitoring\",\"volume\":\"2024 1\",\"pages\":\"\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/5031682\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Control & Health Monitoring\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1155/2024/5031682\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Control & Health Monitoring","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/5031682","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Performance Study of an Autotriggered Anticollapse Fusing Hardware and Its Application on Transmission Lines Subjected to Conductor Breakage
Conductor breakage with ice load is one of the major threats to the safe operation of transmission lines. The ice load increases the unbalanced longitudinal tension, leading to failure of tower members and even progressive collapse of the transmission line. This paper proposes an autotriggered anticollapse fusing hardware (AAFH), designed to reduce the unbalanced longitudinal tension caused by conductor breakage. When the longitudinal unbalanced tension of the transmission line exceeds the threshold of the AAFH, the fused part is destroyed, and the AAFH is elongated to reduce the longitudinal unbalanced tension. First, the construction and working mechanism of the device are introduced, and a numerical model of the transmission line–AAFH system is established to verify its effectiveness. Then, a parameter determination method for unbalanced tension in the tower-line system subjected to conductor breakage is proposed. In addition, the control performance of the device is studied. The results show that AAFH can effectively reduce the unbalanced tension induced by conductor breakage. The proposed method can predict the unbalanced tension of transmission lines, with an error within 10%. The greater the length of vertical/horizontal elongation, the better the protective effect. From a safety perspective, the AAFH should be designed according to the actual transmission line parameters to achieve an ideal control effect.
期刊介绍:
The Journal Structural Control and Health Monitoring encompasses all theoretical and technological aspects of structural control, structural health monitoring theory and smart materials and structures. The journal focuses on aerospace, civil, infrastructure and mechanical engineering applications.
Original contributions based on analytical, computational and experimental methods are solicited in three main areas: monitoring, control, and smart materials and structures, covering subjects such as system identification, health monitoring, health diagnostics, multi-functional materials, signal processing, sensor technology, passive, active and semi active control schemes and implementations, shape memory alloys, piezoelectrics and mechatronics.
Also of interest are actuator design, dynamic systems, dynamic stability, artificial intelligence tools, data acquisition, wireless communications, measurements, MEMS/NEMS sensors for local damage detection, optical fibre sensors for health monitoring, remote control of monitoring systems, sensor-logger combinations for mobile applications, corrosion sensors, scour indicators and experimental techniques.