{"title":"使用冠状动脉内腺苷评估微血管功能障碍的可行性和诊断率的提高","authors":"Hernan Mejia-Renteria, Asad Shabbir, Ivan J Nuñez-Gil, Fernando Macaya, Pablo Salinas, Gabriela Tirado-Conte, Luis Nombela-Franco, Pilar Jimenez-Quevedo, Nieves Gonzalo, Antonio Fernandez-Ortiz, Javier Escaned","doi":"10.1161/JAHA.124.035404","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Bolus thermodilution and intravenous adenosine are established methods for coronary microcirculatory assessment. Yet, its adoption remains low, partly due to procedural time and patient discomfort associated with intravenous adenosine. We investigated differences between intracoronary and intravenous adenosine using bolus thermodilution in terms of microcirculatory indices, procedural time, and side effects associated with adenosine in patients with myocardial ischemia and nonobstructive coronary arteries.</p><p><strong>Methods and results: </strong>In this prospective, observational study, 102 patients with suspected myocardial ischemia and nonobstructive coronary arteries underwent measurements of mean transit time, coronary flow reserve, index of microcirculatory resistance, procedure time and patient tolerability with low-dose intracoronary adenosine, high-dose intracoronary adenosine (HDIC), and intravenous adenosine. HDIC induced greater hyperemia compared with low-dose intracoronary IC adenosine and intravenous adenosine with a shorter hyperemic mean transit time, <i>P</i><0.0001. Coronary flow reserve was higher and index of microcirculatory resistance lowest with HDIC, compared with low-dose intracoronary IC adenosine and intravenous adenosine, <i>P</i><0.05. Low coronary flow reserve was downgraded from 21% with intravenous adenosine to 10% with HDIC adenosine (<i>P</i>=0.031); high index of microcirculatory resistance was downgraded from 23% with intravenous adenosine to 14% with HDIC (<i>P</i>=0.098). Intracoronary adenosine was associated with lower procedural times (<i>P</i><0.0001). More patients experienced chest pain with intravenous adenosine (<i>P</i><0.01) and the chest pain intensity was higher compared with intracoronary adenosine (<i>P</i><0.0001).</p><p><strong>Conclusions: </strong>In patients with suspected myocardial ischemia and nonobstructive coronary arteries undergoing coronary microcirculatory assessment with bolus thermodilution, the use of HDIC compared with intravenous adenosine was associated with enhanced induction of hyperemia. The use of intracoronary adenosine allowed for a shorter procedure time and was better tolerated.</p><p><strong>Registration+: </strong>URL: clinicaltrials.gov; Unique Identifier: NCT04827498.</p>","PeriodicalId":54370,"journal":{"name":"Journal of the American Heart Association","volume":" ","pages":"e035404"},"PeriodicalIF":5.0000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility and Improved Diagnostic Yield of Intracoronary Adenosine to Assess Microvascular Dysfunction With Bolus Thermodilution.\",\"authors\":\"Hernan Mejia-Renteria, Asad Shabbir, Ivan J Nuñez-Gil, Fernando Macaya, Pablo Salinas, Gabriela Tirado-Conte, Luis Nombela-Franco, Pilar Jimenez-Quevedo, Nieves Gonzalo, Antonio Fernandez-Ortiz, Javier Escaned\",\"doi\":\"10.1161/JAHA.124.035404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Bolus thermodilution and intravenous adenosine are established methods for coronary microcirculatory assessment. Yet, its adoption remains low, partly due to procedural time and patient discomfort associated with intravenous adenosine. We investigated differences between intracoronary and intravenous adenosine using bolus thermodilution in terms of microcirculatory indices, procedural time, and side effects associated with adenosine in patients with myocardial ischemia and nonobstructive coronary arteries.</p><p><strong>Methods and results: </strong>In this prospective, observational study, 102 patients with suspected myocardial ischemia and nonobstructive coronary arteries underwent measurements of mean transit time, coronary flow reserve, index of microcirculatory resistance, procedure time and patient tolerability with low-dose intracoronary adenosine, high-dose intracoronary adenosine (HDIC), and intravenous adenosine. HDIC induced greater hyperemia compared with low-dose intracoronary IC adenosine and intravenous adenosine with a shorter hyperemic mean transit time, <i>P</i><0.0001. Coronary flow reserve was higher and index of microcirculatory resistance lowest with HDIC, compared with low-dose intracoronary IC adenosine and intravenous adenosine, <i>P</i><0.05. Low coronary flow reserve was downgraded from 21% with intravenous adenosine to 10% with HDIC adenosine (<i>P</i>=0.031); high index of microcirculatory resistance was downgraded from 23% with intravenous adenosine to 14% with HDIC (<i>P</i>=0.098). Intracoronary adenosine was associated with lower procedural times (<i>P</i><0.0001). More patients experienced chest pain with intravenous adenosine (<i>P</i><0.01) and the chest pain intensity was higher compared with intracoronary adenosine (<i>P</i><0.0001).</p><p><strong>Conclusions: </strong>In patients with suspected myocardial ischemia and nonobstructive coronary arteries undergoing coronary microcirculatory assessment with bolus thermodilution, the use of HDIC compared with intravenous adenosine was associated with enhanced induction of hyperemia. The use of intracoronary adenosine allowed for a shorter procedure time and was better tolerated.</p><p><strong>Registration+: </strong>URL: clinicaltrials.gov; Unique Identifier: NCT04827498.</p>\",\"PeriodicalId\":54370,\"journal\":{\"name\":\"Journal of the American Heart Association\",\"volume\":\" \",\"pages\":\"e035404\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Heart Association\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1161/JAHA.124.035404\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Heart Association","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/JAHA.124.035404","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Feasibility and Improved Diagnostic Yield of Intracoronary Adenosine to Assess Microvascular Dysfunction With Bolus Thermodilution.
Background: Bolus thermodilution and intravenous adenosine are established methods for coronary microcirculatory assessment. Yet, its adoption remains low, partly due to procedural time and patient discomfort associated with intravenous adenosine. We investigated differences between intracoronary and intravenous adenosine using bolus thermodilution in terms of microcirculatory indices, procedural time, and side effects associated with adenosine in patients with myocardial ischemia and nonobstructive coronary arteries.
Methods and results: In this prospective, observational study, 102 patients with suspected myocardial ischemia and nonobstructive coronary arteries underwent measurements of mean transit time, coronary flow reserve, index of microcirculatory resistance, procedure time and patient tolerability with low-dose intracoronary adenosine, high-dose intracoronary adenosine (HDIC), and intravenous adenosine. HDIC induced greater hyperemia compared with low-dose intracoronary IC adenosine and intravenous adenosine with a shorter hyperemic mean transit time, P<0.0001. Coronary flow reserve was higher and index of microcirculatory resistance lowest with HDIC, compared with low-dose intracoronary IC adenosine and intravenous adenosine, P<0.05. Low coronary flow reserve was downgraded from 21% with intravenous adenosine to 10% with HDIC adenosine (P=0.031); high index of microcirculatory resistance was downgraded from 23% with intravenous adenosine to 14% with HDIC (P=0.098). Intracoronary adenosine was associated with lower procedural times (P<0.0001). More patients experienced chest pain with intravenous adenosine (P<0.01) and the chest pain intensity was higher compared with intracoronary adenosine (P<0.0001).
Conclusions: In patients with suspected myocardial ischemia and nonobstructive coronary arteries undergoing coronary microcirculatory assessment with bolus thermodilution, the use of HDIC compared with intravenous adenosine was associated with enhanced induction of hyperemia. The use of intracoronary adenosine allowed for a shorter procedure time and was better tolerated.
期刊介绍:
As an Open Access journal, JAHA - Journal of the American Heart Association is rapidly and freely available, accelerating the translation of strong science into effective practice.
JAHA is an authoritative, peer-reviewed Open Access journal focusing on cardiovascular and cerebrovascular disease. JAHA provides a global forum for basic and clinical research and timely reviews on cardiovascular disease and stroke. As an Open Access journal, its content is free on publication to read, download, and share, accelerating the translation of strong science into effective practice.