Hongyun Yang, Zihan Wang, Xiang Chen, Zhi Lin, Qiang Li
{"title":"基于多参数分析的混凝土火灾诱发损伤试验--以中国隧道衬砌为例","authors":"Hongyun Yang, Zihan Wang, Xiang Chen, Zhi Lin, Qiang Li","doi":"10.1016/j.istruc.2024.107664","DOIUrl":null,"url":null,"abstract":"<div><div>Fires in highway tunnels will have a significant impact on the structural performance of lining materials. A ablation test was conducted on 288 concrete specimens (1500 ×1500 ×1500 mm) with four commonly used grades of C20, C25, C30, and C35 at temperature levels of 300 ℃, 600 ℃, 750 ℃, and 900 ℃ for constant periods of 1 h, 2 h, and 4 h. The experiment revealed that: (1) From low to high temperatures, the specimens experienced cracking, spalling, explosion and eventually complete collapse; all grades of concrete remained intact or mostly intact at 600 ℃ but suffered varying degrees of damage above 750 ℃. (2) At the same fire temperature, the damage rate increased linearly with longer ablation time; while at the same ablation time, the damage rate increased quadratically with higher fire temperature. (3) The ultrasonic wave velocity ratio decreased exponentially as the ablation time increased; higher fire temperatures resulted in lower wave velocity ratios within the same ablation time period and there was a turning point at a two-hour ablation time where specimen integrity was lost. (4) For concrete specimens of the same grade and under identical exposure times to fire, as the fire temperature increased,the rate of compressive strength reduction accelerated significantly; sudden drops in compressive strength occurred at temperatures of 600 °C,750 °C,and900°C,and there was a turning point for compressive strength reduction loss after one hour's ablation to fire.(5) When subjected to high ablation temperatures,the decrease rate in concrete strength exceeded that in wave velocity,and changes in strength were more sensitive than changes in wave velocity.</div></div>","PeriodicalId":48642,"journal":{"name":"Structures","volume":"70 ","pages":"Article 107664"},"PeriodicalIF":3.9000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A test on fire-induced damage of concrete with multiple parameters analysis—Based on tunnel linings of China\",\"authors\":\"Hongyun Yang, Zihan Wang, Xiang Chen, Zhi Lin, Qiang Li\",\"doi\":\"10.1016/j.istruc.2024.107664\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Fires in highway tunnels will have a significant impact on the structural performance of lining materials. A ablation test was conducted on 288 concrete specimens (1500 ×1500 ×1500 mm) with four commonly used grades of C20, C25, C30, and C35 at temperature levels of 300 ℃, 600 ℃, 750 ℃, and 900 ℃ for constant periods of 1 h, 2 h, and 4 h. The experiment revealed that: (1) From low to high temperatures, the specimens experienced cracking, spalling, explosion and eventually complete collapse; all grades of concrete remained intact or mostly intact at 600 ℃ but suffered varying degrees of damage above 750 ℃. (2) At the same fire temperature, the damage rate increased linearly with longer ablation time; while at the same ablation time, the damage rate increased quadratically with higher fire temperature. (3) The ultrasonic wave velocity ratio decreased exponentially as the ablation time increased; higher fire temperatures resulted in lower wave velocity ratios within the same ablation time period and there was a turning point at a two-hour ablation time where specimen integrity was lost. (4) For concrete specimens of the same grade and under identical exposure times to fire, as the fire temperature increased,the rate of compressive strength reduction accelerated significantly; sudden drops in compressive strength occurred at temperatures of 600 °C,750 °C,and900°C,and there was a turning point for compressive strength reduction loss after one hour's ablation to fire.(5) When subjected to high ablation temperatures,the decrease rate in concrete strength exceeded that in wave velocity,and changes in strength were more sensitive than changes in wave velocity.</div></div>\",\"PeriodicalId\":48642,\"journal\":{\"name\":\"Structures\",\"volume\":\"70 \",\"pages\":\"Article 107664\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structures\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352012424018174\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structures","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352012424018174","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
A test on fire-induced damage of concrete with multiple parameters analysis—Based on tunnel linings of China
Fires in highway tunnels will have a significant impact on the structural performance of lining materials. A ablation test was conducted on 288 concrete specimens (1500 ×1500 ×1500 mm) with four commonly used grades of C20, C25, C30, and C35 at temperature levels of 300 ℃, 600 ℃, 750 ℃, and 900 ℃ for constant periods of 1 h, 2 h, and 4 h. The experiment revealed that: (1) From low to high temperatures, the specimens experienced cracking, spalling, explosion and eventually complete collapse; all grades of concrete remained intact or mostly intact at 600 ℃ but suffered varying degrees of damage above 750 ℃. (2) At the same fire temperature, the damage rate increased linearly with longer ablation time; while at the same ablation time, the damage rate increased quadratically with higher fire temperature. (3) The ultrasonic wave velocity ratio decreased exponentially as the ablation time increased; higher fire temperatures resulted in lower wave velocity ratios within the same ablation time period and there was a turning point at a two-hour ablation time where specimen integrity was lost. (4) For concrete specimens of the same grade and under identical exposure times to fire, as the fire temperature increased,the rate of compressive strength reduction accelerated significantly; sudden drops in compressive strength occurred at temperatures of 600 °C,750 °C,and900°C,and there was a turning point for compressive strength reduction loss after one hour's ablation to fire.(5) When subjected to high ablation temperatures,the decrease rate in concrete strength exceeded that in wave velocity,and changes in strength were more sensitive than changes in wave velocity.
期刊介绍:
Structures aims to publish internationally-leading research across the full breadth of structural engineering. Papers for Structures are particularly welcome in which high-quality research will benefit from wide readership of academics and practitioners such that not only high citation rates but also tangible industrial-related pathways to impact are achieved.