Fengjiao Wang, Xiaoyu Bai, Zekun Wu, Nan Yan, Dongshuai Hou, Junwei Liu
{"title":"GFRP 抗浮锚杆外部锚固的现场拉拔试验和锚固长度计算","authors":"Fengjiao Wang, Xiaoyu Bai, Zekun Wu, Nan Yan, Dongshuai Hou, Junwei Liu","doi":"10.1016/j.istruc.2024.107636","DOIUrl":null,"url":null,"abstract":"<div><div>Field pullout destructive tests of GFRP anti-floating anchors with different anchorage lengths and different anchorage forms are carried out on inverted foundation slabs. Explore the damage patterns and anchorage mechanisms of bent anchors, straight anchors and GFRP anchors with different bending configurations in relation to the concrete foundation slab. Calculate the reasonable anchorage length of anti-floating anchors. The test results show that the straight line anchor rod and bent anchor rod are mainly damaged by sliding. The displacement of anchor rod body decreases with the increase of anchorage length, bending radius and bending length. The bending treatment of anchor rods reduces the pullout bearing capacity of GFRP anti-floating anchors, but it can significantly reduce the rod displacement. The longer the length of the bent section of the anchor rod body and the larger the bending radius, the lower the strength utilization of the anchor rod body. Through the calculation of the test results of different anchorage length anti-floating anchor rods, it is found that the current calculation method for the basic anchorage length of anchor rods is too conservative. For the actual anti-floating project, a more reasonable anchorage length calculation method is proposed, and the reasonable anchorage length of anchor rods for this test condition is 370–530 mm.</div></div>","PeriodicalId":48642,"journal":{"name":"Structures","volume":"70 ","pages":"Article 107636"},"PeriodicalIF":3.9000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Field pullout test and anchorage length calculation for external anchorage of GFRP anti-floating anchors\",\"authors\":\"Fengjiao Wang, Xiaoyu Bai, Zekun Wu, Nan Yan, Dongshuai Hou, Junwei Liu\",\"doi\":\"10.1016/j.istruc.2024.107636\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Field pullout destructive tests of GFRP anti-floating anchors with different anchorage lengths and different anchorage forms are carried out on inverted foundation slabs. Explore the damage patterns and anchorage mechanisms of bent anchors, straight anchors and GFRP anchors with different bending configurations in relation to the concrete foundation slab. Calculate the reasonable anchorage length of anti-floating anchors. The test results show that the straight line anchor rod and bent anchor rod are mainly damaged by sliding. The displacement of anchor rod body decreases with the increase of anchorage length, bending radius and bending length. The bending treatment of anchor rods reduces the pullout bearing capacity of GFRP anti-floating anchors, but it can significantly reduce the rod displacement. The longer the length of the bent section of the anchor rod body and the larger the bending radius, the lower the strength utilization of the anchor rod body. Through the calculation of the test results of different anchorage length anti-floating anchor rods, it is found that the current calculation method for the basic anchorage length of anchor rods is too conservative. For the actual anti-floating project, a more reasonable anchorage length calculation method is proposed, and the reasonable anchorage length of anchor rods for this test condition is 370–530 mm.</div></div>\",\"PeriodicalId\":48642,\"journal\":{\"name\":\"Structures\",\"volume\":\"70 \",\"pages\":\"Article 107636\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structures\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352012424017892\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structures","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352012424017892","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Field pullout test and anchorage length calculation for external anchorage of GFRP anti-floating anchors
Field pullout destructive tests of GFRP anti-floating anchors with different anchorage lengths and different anchorage forms are carried out on inverted foundation slabs. Explore the damage patterns and anchorage mechanisms of bent anchors, straight anchors and GFRP anchors with different bending configurations in relation to the concrete foundation slab. Calculate the reasonable anchorage length of anti-floating anchors. The test results show that the straight line anchor rod and bent anchor rod are mainly damaged by sliding. The displacement of anchor rod body decreases with the increase of anchorage length, bending radius and bending length. The bending treatment of anchor rods reduces the pullout bearing capacity of GFRP anti-floating anchors, but it can significantly reduce the rod displacement. The longer the length of the bent section of the anchor rod body and the larger the bending radius, the lower the strength utilization of the anchor rod body. Through the calculation of the test results of different anchorage length anti-floating anchor rods, it is found that the current calculation method for the basic anchorage length of anchor rods is too conservative. For the actual anti-floating project, a more reasonable anchorage length calculation method is proposed, and the reasonable anchorage length of anchor rods for this test condition is 370–530 mm.
期刊介绍:
Structures aims to publish internationally-leading research across the full breadth of structural engineering. Papers for Structures are particularly welcome in which high-quality research will benefit from wide readership of academics and practitioners such that not only high citation rates but also tangible industrial-related pathways to impact are achieved.