{"title":"GFRP 抗浮锚杆外部锚固的现场拉拔试验和锚固长度计算","authors":"Fengjiao Wang,&nbsp;Xiaoyu Bai,&nbsp;Zekun Wu,&nbsp;Nan Yan,&nbsp;Dongshuai Hou,&nbsp;Junwei Liu","doi":"10.1016/j.istruc.2024.107636","DOIUrl":null,"url":null,"abstract":"<div><div>Field pullout destructive tests of GFRP anti-floating anchors with different anchorage lengths and different anchorage forms are carried out on inverted foundation slabs. Explore the damage patterns and anchorage mechanisms of bent anchors, straight anchors and GFRP anchors with different bending configurations in relation to the concrete foundation slab. Calculate the reasonable anchorage length of anti-floating anchors. The test results show that the straight line anchor rod and bent anchor rod are mainly damaged by sliding. The displacement of anchor rod body decreases with the increase of anchorage length, bending radius and bending length. The bending treatment of anchor rods reduces the pullout bearing capacity of GFRP anti-floating anchors, but it can significantly reduce the rod displacement. The longer the length of the bent section of the anchor rod body and the larger the bending radius, the lower the strength utilization of the anchor rod body. Through the calculation of the test results of different anchorage length anti-floating anchor rods, it is found that the current calculation method for the basic anchorage length of anchor rods is too conservative. For the actual anti-floating project, a more reasonable anchorage length calculation method is proposed, and the reasonable anchorage length of anchor rods for this test condition is 370–530 mm.</div></div>","PeriodicalId":48642,"journal":{"name":"Structures","volume":"70 ","pages":"Article 107636"},"PeriodicalIF":3.9000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Field pullout test and anchorage length calculation for external anchorage of GFRP anti-floating anchors\",\"authors\":\"Fengjiao Wang,&nbsp;Xiaoyu Bai,&nbsp;Zekun Wu,&nbsp;Nan Yan,&nbsp;Dongshuai Hou,&nbsp;Junwei Liu\",\"doi\":\"10.1016/j.istruc.2024.107636\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Field pullout destructive tests of GFRP anti-floating anchors with different anchorage lengths and different anchorage forms are carried out on inverted foundation slabs. Explore the damage patterns and anchorage mechanisms of bent anchors, straight anchors and GFRP anchors with different bending configurations in relation to the concrete foundation slab. Calculate the reasonable anchorage length of anti-floating anchors. The test results show that the straight line anchor rod and bent anchor rod are mainly damaged by sliding. The displacement of anchor rod body decreases with the increase of anchorage length, bending radius and bending length. The bending treatment of anchor rods reduces the pullout bearing capacity of GFRP anti-floating anchors, but it can significantly reduce the rod displacement. The longer the length of the bent section of the anchor rod body and the larger the bending radius, the lower the strength utilization of the anchor rod body. Through the calculation of the test results of different anchorage length anti-floating anchor rods, it is found that the current calculation method for the basic anchorage length of anchor rods is too conservative. For the actual anti-floating project, a more reasonable anchorage length calculation method is proposed, and the reasonable anchorage length of anchor rods for this test condition is 370–530 mm.</div></div>\",\"PeriodicalId\":48642,\"journal\":{\"name\":\"Structures\",\"volume\":\"70 \",\"pages\":\"Article 107636\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structures\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352012424017892\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structures","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352012424017892","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

在倒置的基础板上对具有不同锚固长度和不同锚固形式的 GFRP 抗浮锚进行现场拉拔破坏性试验。探讨弯曲锚固件、直锚固件和不同弯曲结构的 GFRP 锚固件与混凝土基础板的损坏模式和锚固机制。计算抗浮锚杆的合理锚固长度。试验结果表明,直线锚杆和弯曲锚杆主要受滑动破坏。锚杆杆体位移随着锚固长度、弯曲半径和弯曲长度的增加而减小。锚杆的弯曲处理会降低 GFRP 抗浮锚杆的抗拔承载能力,但能显著减少杆体位移。锚杆杆体弯曲段长度越长、弯曲半径越大,锚杆杆体的强度利用率越低。通过对不同锚固长度抗浮锚杆试验结果的计算,发现目前锚杆基本锚固长度的计算方法过于保守。针对实际抗浮工程,提出了更为合理的锚固长度计算方法,该试验条件下锚杆的合理锚固长度为 370-530mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Field pullout test and anchorage length calculation for external anchorage of GFRP anti-floating anchors
Field pullout destructive tests of GFRP anti-floating anchors with different anchorage lengths and different anchorage forms are carried out on inverted foundation slabs. Explore the damage patterns and anchorage mechanisms of bent anchors, straight anchors and GFRP anchors with different bending configurations in relation to the concrete foundation slab. Calculate the reasonable anchorage length of anti-floating anchors. The test results show that the straight line anchor rod and bent anchor rod are mainly damaged by sliding. The displacement of anchor rod body decreases with the increase of anchorage length, bending radius and bending length. The bending treatment of anchor rods reduces the pullout bearing capacity of GFRP anti-floating anchors, but it can significantly reduce the rod displacement. The longer the length of the bent section of the anchor rod body and the larger the bending radius, the lower the strength utilization of the anchor rod body. Through the calculation of the test results of different anchorage length anti-floating anchor rods, it is found that the current calculation method for the basic anchorage length of anchor rods is too conservative. For the actual anti-floating project, a more reasonable anchorage length calculation method is proposed, and the reasonable anchorage length of anchor rods for this test condition is 370–530 mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Structures
Structures Engineering-Architecture
CiteScore
5.70
自引率
17.10%
发文量
1187
期刊介绍: Structures aims to publish internationally-leading research across the full breadth of structural engineering. Papers for Structures are particularly welcome in which high-quality research will benefit from wide readership of academics and practitioners such that not only high citation rates but also tangible industrial-related pathways to impact are achieved.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信