提升 CT 成像的患者体验

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mr Mike Wing Tak Lai
{"title":"提升 CT 成像的患者体验","authors":"Mr Mike Wing Tak Lai","doi":"10.1016/j.jmir.2024.101461","DOIUrl":null,"url":null,"abstract":"<div><div>Cardiac CT is the most complicated procedure for CT imaging and Paediatric cardiac CT is even more challenging due to the nature of the patients who may not able to obey the command and keep still during the whole examination procedure. Several challenges for Paediatric cardiac CT includes: The timing of blood flow may be different significantly for patients even with similar body size; wide range of pathology and congenital anomalies for paediatrics and most important of all is the size and body weight of the patient may pose a limitation on the rate and dose of contrast that can be delivered during the cardiac CT examination. In 2019, Hong Kong Children's Hospital commenced the CT services for Paediatric cardiac patients. Through the collaboration of Radiographers and Radiologists, we have developed a set of protocols to optimize the radiation dose, contrast dose and examination routines for our Paediatric patients with different body size and clinical conditions. This presentation aims at providing a holistic approach for Paediatric CT imaging with an in house developed theory to optimize the contrast injection rate and dosage as well as optimizing the use of kVp for imaging to achieve maximum contrast enhancement with reduction of radiation dosage to the patient.</div></div>","PeriodicalId":46420,"journal":{"name":"Journal of Medical Imaging and Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing Patient Experience in CT Imaging\",\"authors\":\"Mr Mike Wing Tak Lai\",\"doi\":\"10.1016/j.jmir.2024.101461\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Cardiac CT is the most complicated procedure for CT imaging and Paediatric cardiac CT is even more challenging due to the nature of the patients who may not able to obey the command and keep still during the whole examination procedure. Several challenges for Paediatric cardiac CT includes: The timing of blood flow may be different significantly for patients even with similar body size; wide range of pathology and congenital anomalies for paediatrics and most important of all is the size and body weight of the patient may pose a limitation on the rate and dose of contrast that can be delivered during the cardiac CT examination. In 2019, Hong Kong Children's Hospital commenced the CT services for Paediatric cardiac patients. Through the collaboration of Radiographers and Radiologists, we have developed a set of protocols to optimize the radiation dose, contrast dose and examination routines for our Paediatric patients with different body size and clinical conditions. This presentation aims at providing a holistic approach for Paediatric CT imaging with an in house developed theory to optimize the contrast injection rate and dosage as well as optimizing the use of kVp for imaging to achieve maximum contrast enhancement with reduction of radiation dosage to the patient.</div></div>\",\"PeriodicalId\":46420,\"journal\":{\"name\":\"Journal of Medical Imaging and Radiation Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Imaging and Radiation Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1939865424001929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1939865424001929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

心脏 CT 是 CT 成像中最复杂的程序,而儿科心脏 CT 则更具挑战性,因为患者的天性使他们在整个检查过程中可能无法服从命令和保持静止。儿童心脏 CT 所面临的挑战包括即使患者的体型相似,血流的时间也可能有很大差异;儿科病理和先天性畸形的范围很广;最重要的是,患者的体型和体重可能会对心脏 CT 检查期间造影剂的输送速度和剂量造成限制。2019 年,香港儿童医院开始为儿科心脏病患者提供 CT 服务。通过放射技师和放射科医生的合作,我们制定了一套方案,针对不同体型和临床情况的儿科患者,优化辐射剂量、造影剂剂量和检查程序。本讲座旨在为儿科 CT 成像提供一种整体方法,通过内部开发的理论来优化造影剂注射率和剂量,并优化成像中 kVp 的使用,从而在减少对患者辐射剂量的同时获得最大的造影剂增强效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhancing Patient Experience in CT Imaging
Cardiac CT is the most complicated procedure for CT imaging and Paediatric cardiac CT is even more challenging due to the nature of the patients who may not able to obey the command and keep still during the whole examination procedure. Several challenges for Paediatric cardiac CT includes: The timing of blood flow may be different significantly for patients even with similar body size; wide range of pathology and congenital anomalies for paediatrics and most important of all is the size and body weight of the patient may pose a limitation on the rate and dose of contrast that can be delivered during the cardiac CT examination. In 2019, Hong Kong Children's Hospital commenced the CT services for Paediatric cardiac patients. Through the collaboration of Radiographers and Radiologists, we have developed a set of protocols to optimize the radiation dose, contrast dose and examination routines for our Paediatric patients with different body size and clinical conditions. This presentation aims at providing a holistic approach for Paediatric CT imaging with an in house developed theory to optimize the contrast injection rate and dosage as well as optimizing the use of kVp for imaging to achieve maximum contrast enhancement with reduction of radiation dosage to the patient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Imaging and Radiation Sciences
Journal of Medical Imaging and Radiation Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
11.10%
发文量
231
审稿时长
53 days
期刊介绍: Journal of Medical Imaging and Radiation Sciences is the official peer-reviewed journal of the Canadian Association of Medical Radiation Technologists. This journal is published four times a year and is circulated to approximately 11,000 medical radiation technologists, libraries and radiology departments throughout Canada, the United States and overseas. The Journal publishes articles on recent research, new technology and techniques, professional practices, technologists viewpoints as well as relevant book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信