{"title":"提高基于氘-氘中子发生器的活体中子活化分析(IVNAA)系统的灵敏度。","authors":"Song Yue, Sana Tabbassum, Elizabeth Helen Jaye, Cheryl A M Anderson, Linda H Nie","doi":"10.1007/s13246-024-01487-w","DOIUrl":null,"url":null,"abstract":"<p><p>Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and clinical use. The method can also be applied to other neutron medical applications, including neutron imaging and radiotherapy.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system.\",\"authors\":\"Song Yue, Sana Tabbassum, Elizabeth Helen Jaye, Cheryl A M Anderson, Linda H Nie\",\"doi\":\"10.1007/s13246-024-01487-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and clinical use. The method can also be applied to other neutron medical applications, including neutron imaging and radiotherapy.</p>\",\"PeriodicalId\":48490,\"journal\":{\"name\":\"Physical and Engineering Sciences in Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical and Engineering Sciences in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s13246-024-01487-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01487-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们的实验室一直在开发一种基于氘-氚(DD)中子发生器的中子活化分析(NAA)系统,用于量化人体内的金属和元素。该系统已用于量化活人骨骼中的锰、铝、钠等金属。该技术为评估金属暴露、估计元素沉积、储存和生物动力学提供了有用的方法。该技术在职业健康和环境健康领域有很大的应用潜力,可用于研究金属暴露与各种健康结果之间的关系,也可用于营养领域,研究人体必需元素的摄入量与人体健康之间的关系。然而,该系统相对较低的灵敏度极大地限制了它的应用。中子慢化在设计 IVNAA 设施中起着重要作用,因为它会影响辐照洞中的热中子通量和人体受到的辐照。本研究旨在开发一种新型热中子增强方法,以提高体内中子活化分析(IVNAA)系统对元素测量的灵敏度,但仍能保持辐射剂量不变。利用紧凑型 DD 中子源,我们提出了一种新型实用的慢化剂设计,将高密度聚乙烯与重水相结合,通过减少热中子吸收来增强热中子。所有材料的尺寸均由通用蒙特卡罗模拟程序 PHITS 计算得出。通过对掺锰的骨等效模型进行实验辐照,验证了蒙特卡洛模拟预测的新设计对其中一种元素锰的定量的改进。在辐射剂量相同的情况下,热中子通量提高了 67.9%。只需增加 4.2% 的辐射剂量,模拟热中子通量和活化就能进一步提高 84.2%。剂量增加 20% 时,热中子增强率也可达到 100%。实验结果清楚地表明,每个特定幻影的锰活化伽马射线计数更高,最低检测限显著降低。此外,光子剂量也得到了抑制。热中子增强方法可以显著增加有用中子的数量,但保持辐射剂量不变。这大大降低了系统在可接受剂量下进行元素定量的检测限,将广泛扩大该技术在研究和临床中的应用。该方法还可应用于其他中子医疗应用,包括中子成像和放射治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sensitivity improvement of a deuterium-deuterium neutron generator based in vivo neutron activation analysis (IVNAA) system.

Our lab has been developing a deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system to quantify metals and elements in the human body in vivo. The system has been used to quantify metals such as manganese, aluminum, sodium in bones of a living human. The technology provides a useful way to assess metal exposure and to estimate elemental deposition, storage and biokinetics. It has great potential to be applied in the occupational and environmental health fields to study the association of metal exposure and various health outcomes, as well as in the nutrition field to study the intake of essential elements and human health. However, the relatively low sensitivity of the system has greatly limited its applications. Neutron moderation plays an important role in designing an IVNAA facility, as it affects thermal neutron flux in irradiation cave and radiation exposure to the human subject. This study aims to develop a novel thermal neutron enhancement method to improve the sensitivity of the in vivo neutron activation analysis (IVNAA) system for elemental measurement but still maintain radiation dose. Utilizing a compact DD neutron source, we propose a new and practical moderator design that combines high density polyethylene with heavy water to enhance thermal neutrons by reducing thermal neutron absorption. All material dimensions are calculated by PHITS, a general-purpose Monte Carlo simulation program. The improvement of the new design predicted by the Monte Carlo simulation for the quantification of one of the elements, manganese was verified by experimental irradiation of manganese-doped bone equivalent phantoms. For the same radiation dose, a 67.9% thermal neutron flux enhancement is reached. With only 4.2% increase of radiation dose, the simulated thermal neutron flux and activation can be further increased by 84.2%. A 100% thermal neutron enhancement ratio is also achievable with a 20% dose increase. The experimental results clearly show higher manganese activation gamma ray counts for each specific phantom, with a significantly reduced minimum detection limit. Additionally, the photon dose was suppressed. The thermal neutron enhancement method can increase the number of useful neutrons significantly but maintain the radiation dose. This greatly decreased the detection limit of the system for elemental quantification at an acceptable dose, which will broadly expand the application of the technology in research and clinical use. The method can also be applied to other neutron medical applications, including neutron imaging and radiotherapy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信