Nikolay Dukov, Vanessa-Mery Valkova, Mariana Yordanova, Virginia Tsapaki, Kristina Bliznakova
{"title":"设计和使用定制模型对射线照相设备进行定期测试:可行性研究","authors":"Nikolay Dukov, Vanessa-Mery Valkova, Mariana Yordanova, Virginia Tsapaki, Kristina Bliznakova","doi":"10.3390/jimaging10100258","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigates the feasibility of employing an in-house-developed physical phantom dedicated to the weekly quality control testing of radiographic systems, performed by radiographers. For this purpose, a 3D phantom was fabricated, featuring test objects, including a model representing a lesion. Alongside this phantom, a commercial phantom, specifically, IBA's Primus L, was utilized. Weekly imaging of both phantoms was conducted over a span of four weeks, involving different imaging protocols and anode voltages. Subsequently, the obtained data underwent visual evaluation, as well as measurement of the intensity of selected regions of interest. The average values for three incident kilovoltages remained consistently stable over the four weeks, with the exception of the \"low energy\" case, which exhibited variability during the first week of measurements. Following experiments in \"Week 1\", the X-Ray unit was identified as malfunctioning and underwent necessary repairs. The in-house-developed phantom demonstrated its utility in assessing the performance of the X-Ray system.</p>","PeriodicalId":37035,"journal":{"name":"Journal of Imaging","volume":"10 10","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11508318/pdf/","citationCount":"0","resultStr":"{\"title\":\"Design and Use of a Custom Phantom for Regular Tests of Radiography Apparatus: A Feasibility Study.\",\"authors\":\"Nikolay Dukov, Vanessa-Mery Valkova, Mariana Yordanova, Virginia Tsapaki, Kristina Bliznakova\",\"doi\":\"10.3390/jimaging10100258\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigates the feasibility of employing an in-house-developed physical phantom dedicated to the weekly quality control testing of radiographic systems, performed by radiographers. For this purpose, a 3D phantom was fabricated, featuring test objects, including a model representing a lesion. Alongside this phantom, a commercial phantom, specifically, IBA's Primus L, was utilized. Weekly imaging of both phantoms was conducted over a span of four weeks, involving different imaging protocols and anode voltages. Subsequently, the obtained data underwent visual evaluation, as well as measurement of the intensity of selected regions of interest. The average values for three incident kilovoltages remained consistently stable over the four weeks, with the exception of the \\\"low energy\\\" case, which exhibited variability during the first week of measurements. Following experiments in \\\"Week 1\\\", the X-Ray unit was identified as malfunctioning and underwent necessary repairs. The in-house-developed phantom demonstrated its utility in assessing the performance of the X-Ray system.</p>\",\"PeriodicalId\":37035,\"journal\":{\"name\":\"Journal of Imaging\",\"volume\":\"10 10\",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11508318/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/jimaging10100258\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jimaging10100258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
本研究探讨了采用内部开发的物理模型的可行性,该模型专门用于放射技师每周对放射成像系统进行的质量控制测试。为此,我们制作了一个三维模型,其中包含测试对象,包括一个代表病变的模型。与该模型同时使用的还有一个商用模型,特别是 IBA 的 Primus L。在为期四周的时间里,对两个模型进行了每周一次的成像,包括不同的成像方案和阳极电压。随后,对所获得的数据进行了目视评估,并对选定感兴趣区域的强度进行了测量。除了 "低能量 "情况在第一周的测量中表现出变化外,其他三种入射千伏电压的平均值在四周内保持稳定。在 "第 1 周 "的实验之后,X 射线装置被确认出现故障,并进行了必要的维修。内部开发的模型证明了其在评估 X 射线系统性能方面的实用性。
Design and Use of a Custom Phantom for Regular Tests of Radiography Apparatus: A Feasibility Study.
This study investigates the feasibility of employing an in-house-developed physical phantom dedicated to the weekly quality control testing of radiographic systems, performed by radiographers. For this purpose, a 3D phantom was fabricated, featuring test objects, including a model representing a lesion. Alongside this phantom, a commercial phantom, specifically, IBA's Primus L, was utilized. Weekly imaging of both phantoms was conducted over a span of four weeks, involving different imaging protocols and anode voltages. Subsequently, the obtained data underwent visual evaluation, as well as measurement of the intensity of selected regions of interest. The average values for three incident kilovoltages remained consistently stable over the four weeks, with the exception of the "low energy" case, which exhibited variability during the first week of measurements. Following experiments in "Week 1", the X-Ray unit was identified as malfunctioning and underwent necessary repairs. The in-house-developed phantom demonstrated its utility in assessing the performance of the X-Ray system.