{"title":"利用非接触式交流电场混合技术对微卫星不稳定性进行术中快速免疫组化。","authors":"Kazuhiro Imai, Naoki Yanagawa, Hajime Saito, Hiroshi Nanjo, Yuki Wakamatsu, Shinogu Takashima, Tsubasa Matsuo, Shoji Kuriyama, Tamotsu Sugai, Yoshihiro Minamiya","doi":"10.1007/s11748-024-02099-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Tumors caused by failure of the DNA-mismatch repair system generally show microsatellite instability (MSI). High-frequency MSI cancers have been shown to be susceptible to immuno-oncology therapies. The aim of this study was to evaluate the clinical reliability of a rapid immunohistochemistry (IHC) technique for intraoperatively assessing molecular status through detection of tumoral deficiencies in the expression of mismatch repair proteins (dMMR; MLH1, MSH2, MSH6, and PMS2).</p><p><strong>Methods: </strong>The rapid IHC method uses non-contact alternating current (AC) mixing to achieve more rapid/stable staining within a minimum of 13 min during surgery. Sixteen formalin-fixed paraffin-embedded (FFPE) tumor samples from 3 dMMR patients with Lynch syndrome and 6 FFPE samples from 6 dMMR-cancer patients were collected to establish an IHC protocol for MMR proteins. Next, 26 surgical patients treated and whose MSI status was determined using PCR-based tests were retrospectively analyzed. The concordance of dMMR diagnoses for thoracic tumors between the conventional (frozen section (FS)- and FFPE-IHCs) and rapid AC-mixing IHC with FSs were compared.</p><p><strong>Results: </strong>A rapid IHC protocol using primary antibodies against four MMR proteins (mixed 5-10 min) was established (entire process within 40 min). The concordance rate for MMR-IHC between the conventional and rapid IHC was 100%. dMMR diagnoses including an MSI-high pulmonary sarcoma patient entirely matched between FS- and FFPE-IHC.</p><p><strong>Conclusion: </strong>Rapid MMR-IHC could potentially serve as a clinical tool for intraoperative determination of tumor MSI/dMMR status. AC-mixing technology will contribute to improving pathological diagnostic capability through the development of an original and innovative rapid IHC.</p>","PeriodicalId":12585,"journal":{"name":"General Thoracic and Cardiovascular Surgery","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraoperative rapid immunohistochemistry of microsatellite instability using non-contact alternating current electric field mixing.\",\"authors\":\"Kazuhiro Imai, Naoki Yanagawa, Hajime Saito, Hiroshi Nanjo, Yuki Wakamatsu, Shinogu Takashima, Tsubasa Matsuo, Shoji Kuriyama, Tamotsu Sugai, Yoshihiro Minamiya\",\"doi\":\"10.1007/s11748-024-02099-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Tumors caused by failure of the DNA-mismatch repair system generally show microsatellite instability (MSI). High-frequency MSI cancers have been shown to be susceptible to immuno-oncology therapies. The aim of this study was to evaluate the clinical reliability of a rapid immunohistochemistry (IHC) technique for intraoperatively assessing molecular status through detection of tumoral deficiencies in the expression of mismatch repair proteins (dMMR; MLH1, MSH2, MSH6, and PMS2).</p><p><strong>Methods: </strong>The rapid IHC method uses non-contact alternating current (AC) mixing to achieve more rapid/stable staining within a minimum of 13 min during surgery. Sixteen formalin-fixed paraffin-embedded (FFPE) tumor samples from 3 dMMR patients with Lynch syndrome and 6 FFPE samples from 6 dMMR-cancer patients were collected to establish an IHC protocol for MMR proteins. Next, 26 surgical patients treated and whose MSI status was determined using PCR-based tests were retrospectively analyzed. The concordance of dMMR diagnoses for thoracic tumors between the conventional (frozen section (FS)- and FFPE-IHCs) and rapid AC-mixing IHC with FSs were compared.</p><p><strong>Results: </strong>A rapid IHC protocol using primary antibodies against four MMR proteins (mixed 5-10 min) was established (entire process within 40 min). The concordance rate for MMR-IHC between the conventional and rapid IHC was 100%. dMMR diagnoses including an MSI-high pulmonary sarcoma patient entirely matched between FS- and FFPE-IHC.</p><p><strong>Conclusion: </strong>Rapid MMR-IHC could potentially serve as a clinical tool for intraoperative determination of tumor MSI/dMMR status. AC-mixing technology will contribute to improving pathological diagnostic capability through the development of an original and innovative rapid IHC.</p>\",\"PeriodicalId\":12585,\"journal\":{\"name\":\"General Thoracic and Cardiovascular Surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"General Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11748-024-02099-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"General Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11748-024-02099-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Intraoperative rapid immunohistochemistry of microsatellite instability using non-contact alternating current electric field mixing.
Objectives: Tumors caused by failure of the DNA-mismatch repair system generally show microsatellite instability (MSI). High-frequency MSI cancers have been shown to be susceptible to immuno-oncology therapies. The aim of this study was to evaluate the clinical reliability of a rapid immunohistochemistry (IHC) technique for intraoperatively assessing molecular status through detection of tumoral deficiencies in the expression of mismatch repair proteins (dMMR; MLH1, MSH2, MSH6, and PMS2).
Methods: The rapid IHC method uses non-contact alternating current (AC) mixing to achieve more rapid/stable staining within a minimum of 13 min during surgery. Sixteen formalin-fixed paraffin-embedded (FFPE) tumor samples from 3 dMMR patients with Lynch syndrome and 6 FFPE samples from 6 dMMR-cancer patients were collected to establish an IHC protocol for MMR proteins. Next, 26 surgical patients treated and whose MSI status was determined using PCR-based tests were retrospectively analyzed. The concordance of dMMR diagnoses for thoracic tumors between the conventional (frozen section (FS)- and FFPE-IHCs) and rapid AC-mixing IHC with FSs were compared.
Results: A rapid IHC protocol using primary antibodies against four MMR proteins (mixed 5-10 min) was established (entire process within 40 min). The concordance rate for MMR-IHC between the conventional and rapid IHC was 100%. dMMR diagnoses including an MSI-high pulmonary sarcoma patient entirely matched between FS- and FFPE-IHC.
Conclusion: Rapid MMR-IHC could potentially serve as a clinical tool for intraoperative determination of tumor MSI/dMMR status. AC-mixing technology will contribute to improving pathological diagnostic capability through the development of an original and innovative rapid IHC.
期刊介绍:
The General Thoracic and Cardiovascular Surgery is the official publication of The Japanese Association for Thoracic Surgery and The Japanese Association for Chest Surgery, the affiliated journal of The Japanese Society for Cardiovascular Surgery, that publishes clinical and experimental studies in fields related to thoracic and cardiovascular surgery.