{"title":"术中插入主动脉内球囊泵:逐步进行。","authors":"Carla Gotsens-Asenjo, Constanza Fernández-De Vinzenzi, Elena Roselló-Díez, César Piedra, Marta Molina, Juan Francisco Tabilo, Manel Tauron, Sandra Casellas, Ángela Irabién, Laura Corominas, Antonino Ginel, Jose Montiel","doi":"10.1510/mmcts.2024.066","DOIUrl":null,"url":null,"abstract":"<p><p>A 76-year-old patient with non-ST elevation myocardial infarction was admitted to our hospital. Coronary angiography revealed significant left main and two-vessel coronary artery disease. Preoperative testing indicated severe left ventricular dysfunction. The patient was scheduled for urgent off-pump coronary artery bypass grafting. Due to the low ejection fraction, an intra-aortic balloon pump was inserted in the operating theatre before sternotomy, to enhance the patient's haemodynamic stability during surgery. A 6 Fr introducer was inserted into the femoral artery under echocardiographic guidance. Using a 150-cm guidewire, the intra-aortic balloon catheter was advanced through the introducer to the descending thoracic aorta. The catheter's tip position, just distal to the origin of the left subclavian artery, was confirmed via transoesophageal echocardiography. The external part of the catheter was secured to the skin and connected to the balloon console. Therapy was initiated, and the inflation/deflation parameters were optimized. A double off-pump coronary artery bypass was performed via median sternotomy. The patient remained haemodynamically stable throughout the surgery, aided by the intra-aortic balloon pump, and careful volume and vasoactive management. The patient was extubated promptly, and the device was removed on the second postoperative day without complications.</p>","PeriodicalId":53474,"journal":{"name":"Multimedia manual of cardiothoracic surgery : MMCTS / European Association for Cardio-Thoracic Surgery","volume":"2024 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraoperative intra-aortic balloon pump insertion: step by step.\",\"authors\":\"Carla Gotsens-Asenjo, Constanza Fernández-De Vinzenzi, Elena Roselló-Díez, César Piedra, Marta Molina, Juan Francisco Tabilo, Manel Tauron, Sandra Casellas, Ángela Irabién, Laura Corominas, Antonino Ginel, Jose Montiel\",\"doi\":\"10.1510/mmcts.2024.066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A 76-year-old patient with non-ST elevation myocardial infarction was admitted to our hospital. Coronary angiography revealed significant left main and two-vessel coronary artery disease. Preoperative testing indicated severe left ventricular dysfunction. The patient was scheduled for urgent off-pump coronary artery bypass grafting. Due to the low ejection fraction, an intra-aortic balloon pump was inserted in the operating theatre before sternotomy, to enhance the patient's haemodynamic stability during surgery. A 6 Fr introducer was inserted into the femoral artery under echocardiographic guidance. Using a 150-cm guidewire, the intra-aortic balloon catheter was advanced through the introducer to the descending thoracic aorta. The catheter's tip position, just distal to the origin of the left subclavian artery, was confirmed via transoesophageal echocardiography. The external part of the catheter was secured to the skin and connected to the balloon console. Therapy was initiated, and the inflation/deflation parameters were optimized. A double off-pump coronary artery bypass was performed via median sternotomy. The patient remained haemodynamically stable throughout the surgery, aided by the intra-aortic balloon pump, and careful volume and vasoactive management. The patient was extubated promptly, and the device was removed on the second postoperative day without complications.</p>\",\"PeriodicalId\":53474,\"journal\":{\"name\":\"Multimedia manual of cardiothoracic surgery : MMCTS / European Association for Cardio-Thoracic Surgery\",\"volume\":\"2024 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Multimedia manual of cardiothoracic surgery : MMCTS / European Association for Cardio-Thoracic Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1510/mmcts.2024.066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Multimedia manual of cardiothoracic surgery : MMCTS / European Association for Cardio-Thoracic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1510/mmcts.2024.066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

我院收治了一名 76 岁的非 ST 段抬高型心肌梗死患者。冠状动脉造影显示患者左主干和双腔冠状动脉病变严重。术前检查显示左心室功能严重障碍。患者被紧急安排接受体外循环冠状动脉旁路移植术。由于患者射血分数较低,在手术室进行胸骨切开术前插入了主动脉内球囊泵,以增强患者术中血流动力学的稳定性。在超声心动图引导下,将 6 Fr 导管插入股动脉。使用 150 厘米长的导丝,通过导引器将主动脉内球囊导管推进到降胸主动脉。通过经食道超声心动图确认导管顶端的位置,即左锁骨下动脉起源的远端。将导管外部固定在皮肤上,并连接到球囊控制台。治疗开始,充气/放气参数得到优化。经胸骨正中切口进行了双腔外冠状动脉搭桥术。在主动脉内球囊泵的帮助下,患者在整个手术过程中保持了血流动力学稳定,并进行了仔细的容量和血管活性管理。患者被及时拔管,术后第二天就取出了装置,没有出现并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intraoperative intra-aortic balloon pump insertion: step by step.

A 76-year-old patient with non-ST elevation myocardial infarction was admitted to our hospital. Coronary angiography revealed significant left main and two-vessel coronary artery disease. Preoperative testing indicated severe left ventricular dysfunction. The patient was scheduled for urgent off-pump coronary artery bypass grafting. Due to the low ejection fraction, an intra-aortic balloon pump was inserted in the operating theatre before sternotomy, to enhance the patient's haemodynamic stability during surgery. A 6 Fr introducer was inserted into the femoral artery under echocardiographic guidance. Using a 150-cm guidewire, the intra-aortic balloon catheter was advanced through the introducer to the descending thoracic aorta. The catheter's tip position, just distal to the origin of the left subclavian artery, was confirmed via transoesophageal echocardiography. The external part of the catheter was secured to the skin and connected to the balloon console. Therapy was initiated, and the inflation/deflation parameters were optimized. A double off-pump coronary artery bypass was performed via median sternotomy. The patient remained haemodynamically stable throughout the surgery, aided by the intra-aortic balloon pump, and careful volume and vasoactive management. The patient was extubated promptly, and the device was removed on the second postoperative day without complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
60
期刊介绍: The Multimedia Manual of Cardio-Thoracic Surgery (MMCTS) is produced by The European Association for Cardio-Thoracic Surgery (EACTS). MMCTS is the world’s premier video-based educational resource for cardiovascular and thoracic surgeons; freely accessible - and essential - for all. MMCTS was launched more than ten years ago under the leadership of founding editor Professor Marko Turina. It was Professor Turina’s vision that the European Association for Cardio-Thoracic Surgery (EACTS), already the world-leader in CT surgery education, should take advantage of the Internet’s rapidly improving video publication capabilities and create a new step-by-step manual of surgical procedures. Professor Turina and EACTS agreed that the manual, MMCTS, should be freely accessible to all users, regardless of association membership status, nationality, or affiliation. MMCTS was self-published by EACTS for some years before being transferred to Oxford University Press, which hosted it until the end of 2016. In November 2016, the Manual returned home to EACTS and it has now relaunched in a completely new format. Since its birth in 2005, MMCTS has published some 400 detailed, video-based demonstrations of cardio-thoracic surgical procedures. Tutorials published prior to 2012 have been archived and we are working with the authors of these tutorials to update their work pending republication on the new site. Our mission is to make MMCTS the best online reference for cardio-thoracic surgeons – residents and experienced surgeons alike. Our aim is to include tutorials presenting procedures at both a fundamental and an advanced level. Truly innovative procedures are also included and are identified as such.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信