三维计算机辅助导航的上颈椎后路固定手术技术:三个病例的说明。

Q1 Medicine
Journal of spine surgery Pub Date : 2024-09-23 Epub Date: 2024-07-04 DOI:10.21037/jss-24-26
Franziska C S Altorfer, Fedan Avrumova, Gregory Paschal, Marco D Burkhard, Darren R Lebl
{"title":"三维计算机辅助导航的上颈椎后路固定手术技术:三个病例的说明。","authors":"Franziska C S Altorfer, Fedan Avrumova, Gregory Paschal, Marco D Burkhard, Darren R Lebl","doi":"10.21037/jss-24-26","DOIUrl":null,"url":null,"abstract":"<p><p>Instrumentation of the upper cervical spine, such as cervical pedicle, lateral mass, pars, or translaminar screws, is considered high risk due to the specific challenges of this anatomic region, including the proximity of vertebral and carotid arteries and nerve roots, as well as its delicate bony architecture. In recent years, advanced three-dimensional (3D) imaging techniques, such as intraoperative computed tomography (iCT; AIRO CT), have emerged, enabling computer-assisted navigation (CAN). This integration of real-time imaging into navigation enhances screw accuracy and diminishes perioperative risks, extending to the postsurgical confirmation of screw placement. Although CAN utilization has become more prominent in lumbar and thoracic surgeries, its integration into cervical spine procedures has been constrained thus far. This can be ascribed to the variable screw trajectories necessary for cervical spine procedures, coupled with potential anatomical variations such as a high-riding vertebral artery, increasing the degree of challenge during surgery. To date, no study has comprehensively described in detail the technique of upper cervical instrumentation employing automatic image registration, navigation, and iCT validation of the positioned screws. In this manuscript, a detailed description of CAN in high cervical instrumentation is given, including C1 lateral mass screws with the notching technique, C2 and C3 pars screws, and translaminar screws guided by preoperative magnetic resonance imaging (MRI) data and iCT for assessment of screw position. For this purpose, three different patients suffering from distinct cervical pathologies, such as nonunion of a C2 fracture and atlantoaxial arthropathy with or without ankylosis, are presented, with a specific surgical approach tailored to the anatomical variations of each patient.</p>","PeriodicalId":17131,"journal":{"name":"Journal of spine surgery","volume":"10 3","pages":"521-539"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11467279/pdf/","citationCount":"0","resultStr":"{\"title\":\"Surgical technique of 3D computer-assisted navigated posterior fixation of the upper cervical spine: illustration of three cases.\",\"authors\":\"Franziska C S Altorfer, Fedan Avrumova, Gregory Paschal, Marco D Burkhard, Darren R Lebl\",\"doi\":\"10.21037/jss-24-26\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Instrumentation of the upper cervical spine, such as cervical pedicle, lateral mass, pars, or translaminar screws, is considered high risk due to the specific challenges of this anatomic region, including the proximity of vertebral and carotid arteries and nerve roots, as well as its delicate bony architecture. In recent years, advanced three-dimensional (3D) imaging techniques, such as intraoperative computed tomography (iCT; AIRO CT), have emerged, enabling computer-assisted navigation (CAN). This integration of real-time imaging into navigation enhances screw accuracy and diminishes perioperative risks, extending to the postsurgical confirmation of screw placement. Although CAN utilization has become more prominent in lumbar and thoracic surgeries, its integration into cervical spine procedures has been constrained thus far. This can be ascribed to the variable screw trajectories necessary for cervical spine procedures, coupled with potential anatomical variations such as a high-riding vertebral artery, increasing the degree of challenge during surgery. To date, no study has comprehensively described in detail the technique of upper cervical instrumentation employing automatic image registration, navigation, and iCT validation of the positioned screws. In this manuscript, a detailed description of CAN in high cervical instrumentation is given, including C1 lateral mass screws with the notching technique, C2 and C3 pars screws, and translaminar screws guided by preoperative magnetic resonance imaging (MRI) data and iCT for assessment of screw position. For this purpose, three different patients suffering from distinct cervical pathologies, such as nonunion of a C2 fracture and atlantoaxial arthropathy with or without ankylosis, are presented, with a specific surgical approach tailored to the anatomical variations of each patient.</p>\",\"PeriodicalId\":17131,\"journal\":{\"name\":\"Journal of spine surgery\",\"volume\":\"10 3\",\"pages\":\"521-539\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11467279/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of spine surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21037/jss-24-26\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of spine surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21037/jss-24-26","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

上颈椎的器械治疗,如颈椎椎弓根、侧块、椎旁或椎板间螺钉,被认为是高风险的,因为这一解剖区域具有特殊的挑战性,包括靠近椎动脉、颈动脉和神经根,以及其脆弱的骨骼结构。近年来,术中计算机断层扫描(iCT;AIRO CT)等先进的三维(3D)成像技术应运而生,实现了计算机辅助导航(CAN)。这种将实时成像整合到导航中的技术提高了螺钉的准确性,降低了围手术期的风险,并延伸到手术后螺钉置放的确认。虽然计算机辅助导航在腰椎和胸椎手术中的应用越来越突出,但迄今为止,它在颈椎手术中的应用还很有限。这可能是由于颈椎手术所需的螺钉轨迹多变,再加上潜在的解剖变异(如高位椎动脉),增加了手术中的挑战程度。迄今为止,还没有研究全面详细地描述了采用自动图像注册、导航和 iCT 验证定位螺钉的上颈椎器械技术。本手稿详细描述了 CAN 在高颈椎器械中的应用,包括采用切口技术的 C1 侧块螺钉、C2 和 C3 旁螺钉,以及通过术前磁共振成像(MRI)数据和用于评估螺钉位置的 iCT 引导的层间螺钉。为此,本文介绍了三位不同的颈椎病患者,如 C2 骨折不愈合和伴有或不伴有强直的寰枢关节病患者,并根据每位患者的解剖结构变化介绍了具体的手术方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Surgical technique of 3D computer-assisted navigated posterior fixation of the upper cervical spine: illustration of three cases.

Instrumentation of the upper cervical spine, such as cervical pedicle, lateral mass, pars, or translaminar screws, is considered high risk due to the specific challenges of this anatomic region, including the proximity of vertebral and carotid arteries and nerve roots, as well as its delicate bony architecture. In recent years, advanced three-dimensional (3D) imaging techniques, such as intraoperative computed tomography (iCT; AIRO CT), have emerged, enabling computer-assisted navigation (CAN). This integration of real-time imaging into navigation enhances screw accuracy and diminishes perioperative risks, extending to the postsurgical confirmation of screw placement. Although CAN utilization has become more prominent in lumbar and thoracic surgeries, its integration into cervical spine procedures has been constrained thus far. This can be ascribed to the variable screw trajectories necessary for cervical spine procedures, coupled with potential anatomical variations such as a high-riding vertebral artery, increasing the degree of challenge during surgery. To date, no study has comprehensively described in detail the technique of upper cervical instrumentation employing automatic image registration, navigation, and iCT validation of the positioned screws. In this manuscript, a detailed description of CAN in high cervical instrumentation is given, including C1 lateral mass screws with the notching technique, C2 and C3 pars screws, and translaminar screws guided by preoperative magnetic resonance imaging (MRI) data and iCT for assessment of screw position. For this purpose, three different patients suffering from distinct cervical pathologies, such as nonunion of a C2 fracture and atlantoaxial arthropathy with or without ankylosis, are presented, with a specific surgical approach tailored to the anatomical variations of each patient.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of spine surgery
Journal of spine surgery Medicine-Surgery
CiteScore
5.60
自引率
0.00%
发文量
24
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信