Jianjun Li, Jacek Stupak, Arsalan S Haqqani, Greg Harris, Hongyan Zhou, Sam Williamson, Rui Chen, H Howard Xu, Wangxue Chen
{"title":"开发 LC-FAIMS-MS 并将其应用于鲍曼不动杆菌感染的脂质组学研究。","authors":"Jianjun Li, Jacek Stupak, Arsalan S Haqqani, Greg Harris, Hongyan Zhou, Sam Williamson, Rui Chen, H Howard Xu, Wangxue Chen","doi":"10.1016/j.jlr.2024.100668","DOIUrl":null,"url":null,"abstract":"<p><p>The recent advances in mass spectrometry (MS) technologies have enabled comprehensive lipid profiling in biological samples. However, the robustness and efficiency of MS-based lipidomics is compromised by the complexity of biological samples. High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a technology that can continuously transmit one type of ion, independent of the mass-to-charge ratio. Here we present the development and application of LC-FAIMS-MS/MS-based platform for untargeted lipidomics. We used 3 optimally balanced compensation voltages, i.e., 29 V, 34 V and 39 V, to analyze all subclasses of glycerophospholipids. The reproducibility of the method was evaluated using reference standards. The reproducibility of retention times ranged from 0.9% to 1.5% RSD; whereas RSD values of 5%-10% were observed for peak areas. More importantly, the coupling of a FAIMS device can significantly improve the robustness and efficiency. We exploited this NPLC-FAIMS-HRMS to analyze the serum lipid profiles in mice infected intranasally with Acinetobacter baumannii. The temporal profiles of serum lipids after A. baumannii inoculation were obtained for 4 h, 8 h, and 24 h. We found that nearly all ether PC and ether PE lipids were significantly decreased 8 h after inoculation. The resultant volcano plot illustrated the distribution of 28 increased and 28 decreased lipid species in mouse sera 24 h after inoculation. We also found that a single ether PE composition can comprise multiple isomeric structures, and the relative abundance of each isomer could be quantified using the newly developed NPLC-FAIMS-PRM method. We have demonstrated that the proposed LC-FAIMS-MS is a valuable platform for lipidomics.</p>","PeriodicalId":16209,"journal":{"name":"Journal of Lipid Research","volume":" ","pages":"100668"},"PeriodicalIF":5.0000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11577210/pdf/","citationCount":"0","resultStr":"{\"title\":\"Development of LC-FAIMS-MS and its application to lipidomics study of Acinetobacter baumannii infection.\",\"authors\":\"Jianjun Li, Jacek Stupak, Arsalan S Haqqani, Greg Harris, Hongyan Zhou, Sam Williamson, Rui Chen, H Howard Xu, Wangxue Chen\",\"doi\":\"10.1016/j.jlr.2024.100668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The recent advances in mass spectrometry (MS) technologies have enabled comprehensive lipid profiling in biological samples. However, the robustness and efficiency of MS-based lipidomics is compromised by the complexity of biological samples. High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a technology that can continuously transmit one type of ion, independent of the mass-to-charge ratio. Here we present the development and application of LC-FAIMS-MS/MS-based platform for untargeted lipidomics. We used 3 optimally balanced compensation voltages, i.e., 29 V, 34 V and 39 V, to analyze all subclasses of glycerophospholipids. The reproducibility of the method was evaluated using reference standards. The reproducibility of retention times ranged from 0.9% to 1.5% RSD; whereas RSD values of 5%-10% were observed for peak areas. More importantly, the coupling of a FAIMS device can significantly improve the robustness and efficiency. We exploited this NPLC-FAIMS-HRMS to analyze the serum lipid profiles in mice infected intranasally with Acinetobacter baumannii. The temporal profiles of serum lipids after A. baumannii inoculation were obtained for 4 h, 8 h, and 24 h. We found that nearly all ether PC and ether PE lipids were significantly decreased 8 h after inoculation. The resultant volcano plot illustrated the distribution of 28 increased and 28 decreased lipid species in mouse sera 24 h after inoculation. We also found that a single ether PE composition can comprise multiple isomeric structures, and the relative abundance of each isomer could be quantified using the newly developed NPLC-FAIMS-PRM method. We have demonstrated that the proposed LC-FAIMS-MS is a valuable platform for lipidomics.</p>\",\"PeriodicalId\":16209,\"journal\":{\"name\":\"Journal of Lipid Research\",\"volume\":\" \",\"pages\":\"100668\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11577210/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Lipid Research\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jlr.2024.100668\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Lipid Research","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1016/j.jlr.2024.100668","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Development of LC-FAIMS-MS and its application to lipidomics study of Acinetobacter baumannii infection.
The recent advances in mass spectrometry (MS) technologies have enabled comprehensive lipid profiling in biological samples. However, the robustness and efficiency of MS-based lipidomics is compromised by the complexity of biological samples. High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a technology that can continuously transmit one type of ion, independent of the mass-to-charge ratio. Here we present the development and application of LC-FAIMS-MS/MS-based platform for untargeted lipidomics. We used 3 optimally balanced compensation voltages, i.e., 29 V, 34 V and 39 V, to analyze all subclasses of glycerophospholipids. The reproducibility of the method was evaluated using reference standards. The reproducibility of retention times ranged from 0.9% to 1.5% RSD; whereas RSD values of 5%-10% were observed for peak areas. More importantly, the coupling of a FAIMS device can significantly improve the robustness and efficiency. We exploited this NPLC-FAIMS-HRMS to analyze the serum lipid profiles in mice infected intranasally with Acinetobacter baumannii. The temporal profiles of serum lipids after A. baumannii inoculation were obtained for 4 h, 8 h, and 24 h. We found that nearly all ether PC and ether PE lipids were significantly decreased 8 h after inoculation. The resultant volcano plot illustrated the distribution of 28 increased and 28 decreased lipid species in mouse sera 24 h after inoculation. We also found that a single ether PE composition can comprise multiple isomeric structures, and the relative abundance of each isomer could be quantified using the newly developed NPLC-FAIMS-PRM method. We have demonstrated that the proposed LC-FAIMS-MS is a valuable platform for lipidomics.
期刊介绍:
The Journal of Lipid Research (JLR) publishes original articles and reviews in the broadly defined area of biological lipids. We encourage the submission of manuscripts relating to lipids, including those addressing problems in biochemistry, molecular biology, structural biology, cell biology, genetics, molecular medicine, clinical medicine and metabolism. Major criteria for acceptance of articles are new insights into mechanisms of lipid function and metabolism and/or genes regulating lipid metabolism along with sound primary experimental data. Interpretation of the data is the authors’ responsibility, and speculation should be labeled as such. Manuscripts that provide new ways of purifying, identifying and quantifying lipids are invited for the Methods section of the Journal. JLR encourages contributions from investigators in all countries, but articles must be submitted in clear and concise English.