利用患者特异性流体-结构相互作用模型评估主动脉夹层重塑。

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Kathrin Baumler, Malte Rolf-Pissarczyk, Richard Schussnig, Thomas-Peter Fries, Gabriel Mistelbauer, Martin R Pfaller, Alison L Marsden, Dominik Fleischmann, Gerhard A Holzapfel
{"title":"利用患者特异性流体-结构相互作用模型评估主动脉夹层重塑。","authors":"Kathrin Baumler, Malte Rolf-Pissarczyk, Richard Schussnig, Thomas-Peter Fries, Gabriel Mistelbauer, Martin R Pfaller, Alison L Marsden, Dominik Fleischmann, Gerhard A Holzapfel","doi":"10.1109/TBME.2024.3480362","DOIUrl":null,"url":null,"abstract":"<p><p>Aortic dissection leads to late complications due to chronic degeneration and dilatation of the false lumen. However, the interaction between hemodynamics and microstructural remodeling driving long-term changes is not fully understood. This study examines the progression of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using computed tomography angiography. Fluid-structure interaction models that account for tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Quantitative measurements during routine clinical care showed that aortic dilatation was most significant distal to the left subclavian artery, reaching 6cm in the chronic phase. Simulations resulted in a flow jet velocity through the entry tear that peaked at 185cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2mmHg in the subacute and chronic phases, with the wall shear stress reaching 4,Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8mm as disease progressed, which was associated with an overall increase in aortic diameter. Additional simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of aortic dissection remodeling with patient-specific fluid-structure interaction models.\",\"authors\":\"Kathrin Baumler, Malte Rolf-Pissarczyk, Richard Schussnig, Thomas-Peter Fries, Gabriel Mistelbauer, Martin R Pfaller, Alison L Marsden, Dominik Fleischmann, Gerhard A Holzapfel\",\"doi\":\"10.1109/TBME.2024.3480362\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Aortic dissection leads to late complications due to chronic degeneration and dilatation of the false lumen. However, the interaction between hemodynamics and microstructural remodeling driving long-term changes is not fully understood. This study examines the progression of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using computed tomography angiography. Fluid-structure interaction models that account for tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Quantitative measurements during routine clinical care showed that aortic dilatation was most significant distal to the left subclavian artery, reaching 6cm in the chronic phase. Simulations resulted in a flow jet velocity through the entry tear that peaked at 185cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2mmHg in the subacute and chronic phases, with the wall shear stress reaching 4,Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8mm as disease progressed, which was associated with an overall increase in aortic diameter. Additional simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.</p>\",\"PeriodicalId\":13245,\"journal\":{\"name\":\"IEEE Transactions on Biomedical Engineering\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1109/TBME.2024.3480362\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2024.3480362","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

主动脉夹层会导致假腔慢性变性和扩张,从而引发晚期并发症。然而,血液动力学和微结构重塑之间的相互作用如何推动长期变化尚未完全明了。本研究使用计算机断层扫描血管造影术对主动脉夹层患者从夹层前到慢性阶段的进展情况进行了研究。流体-结构相互作用模型考虑了组织预应力、外部支撑和各向异性,用于分析血液动力学标记。每个主动脉壁层都有不同的厚度和材料特性。边界条件以体外 4D 流磁共振成像和患者血压为指导。常规临床护理期间的定量测量显示,主动脉扩张在左锁骨下动脉远端最为显著,在慢性期达到 6 厘米。模拟结果显示,流经入口撕裂处的射流速度在亚急性期达到 185 厘米/秒的峰值,而在慢性期则降至 123 至 133 厘米/秒,这与入口撕裂的增大相对应。在亚急性期和慢性期,血流射流撞击假腔导致局部压力分别增加 11 和 2 毫米汞柱,管壁剪应力达到 4,Pa 。这些血流动力学变化似乎是主动脉生长和形态变化的主要驱动力。尽管皮瓣整体移动幅度不大,但随着病情的发展,平面内位移从 0.6 毫米增加到 1.8 毫米,这与主动脉直径的整体增加有关。在亚急性阶段,皮瓣硬度显著降低的额外模拟导致皮瓣运动增加到 9.5 毫米。尽管这些结果是基于单个患者,但它们表明血液动力学与主动脉生长之间存在密切关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of aortic dissection remodeling with patient-specific fluid-structure interaction models.

Aortic dissection leads to late complications due to chronic degeneration and dilatation of the false lumen. However, the interaction between hemodynamics and microstructural remodeling driving long-term changes is not fully understood. This study examines the progression of a patient's aortic dissection, tracked from pre-dissection to the chronic phase using computed tomography angiography. Fluid-structure interaction models that account for tissue prestress, external support, and anisotropic properties were used to analyze hemodynamic markers. Each aortic wall layer had distinct thicknesses and material properties. The boundary conditions were guided by in vitro 4D-flow MRI and the patient's blood pressure. Quantitative measurements during routine clinical care showed that aortic dilatation was most significant distal to the left subclavian artery, reaching 6cm in the chronic phase. Simulations resulted in a flow jet velocity through the entry tear that peaked at 185cm/s in the subacute phase and decreased to 123 to 133 cm/s in the chronic phase, corresponding to an increased entry tear size. Flow jet impingement on the false lumen resulted in a localized pressure increase of 11 and 2mmHg in the subacute and chronic phases, with the wall shear stress reaching 4,Pa. These hemodynamic changes appear to be the main drivers of aortic growth and morphological changes. Despite moderate overall flap movement, in-plane displacement increased from 0.6 to 1.8mm as disease progressed, which was associated with an overall increase in aortic diameter. Additional simulations with a significant reduction in flap stiffness during the subacute phase resulted in increased flap motion up to 9.5mm. Although these results are based on a single patient, they suggest a strong relationship between hemodynamics and aortic growth.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信