右心室造影引导起搏诱发型心肌病的左束支起搏:一份新颖的病例报告。

Pub Date : 2024-09-24 eCollection Date: 2024-10-01 DOI:10.1093/ehjcr/ytae494
Mansimran Singh Dulay, Raheel Ahmed, Nick Child, Ahran Arnold, Mark Tanner
{"title":"右心室造影引导起搏诱发型心肌病的左束支起搏:一份新颖的病例报告。","authors":"Mansimran Singh Dulay, Raheel Ahmed, Nick Child, Ahran Arnold, Mark Tanner","doi":"10.1093/ehjcr/ytae494","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is emerging evidence for the potential utility of left bundle branch area pacing (LBBAP), as an alternative to conventional cardiac resynchronization therapy (CRT). The utility of right ventriculography by way of power injector to facilitate lead placement has not yet been reported in the literature.</p><p><strong>Case summary: </strong>A 79-year-old female, with a background of poorly rate-controlled atrial fibrillation, presented with worsening dyspnoea. She had recently undergone single-chamber pacemaker insertion prior to an atrioventricular nodal (AVN) ablation, owing to failure in achieving successful CRT coronary sinus lead placement. She had clinical evidence of volume overload, and her electrocardiogram demonstrated right ventricular pacing. Echocardiography demonstrated left ventricular (LV) impairment, with an ejection fraction (EF) of 35%, and severe functional mitral regurgitation (MR). Her diagnosis was overall consistent with pacing-induced cardiomyopathy (PIC). In this patient, the use of right ventriculography, using power-injector-delivered contrast, successfully facilitated placement of an LBBAP lead, with confirmation of good threshold and sensing parameters. Following an upgrade to conduction system pacing, the patient recovered well. On recent follow-up, repeat echocardiography (24 months post initial presentation) demonstrated improved LV function (EF 45% from 35%) and only mild-to-moderate MR.</p><p><strong>Discussion: </strong>In conclusion, we demonstrate the utility of right ventriculography to facilitate placement of an LBBAP lead, successfully treating a patient who developed PIC from chronic right ventricular pacing following AVN ablation.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443961/pdf/","citationCount":"0","resultStr":"{\"title\":\"Right ventriculography to guide left bundle branch pacing in pacing-induced cardiomyopathy: a novel case report.\",\"authors\":\"Mansimran Singh Dulay, Raheel Ahmed, Nick Child, Ahran Arnold, Mark Tanner\",\"doi\":\"10.1093/ehjcr/ytae494\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There is emerging evidence for the potential utility of left bundle branch area pacing (LBBAP), as an alternative to conventional cardiac resynchronization therapy (CRT). The utility of right ventriculography by way of power injector to facilitate lead placement has not yet been reported in the literature.</p><p><strong>Case summary: </strong>A 79-year-old female, with a background of poorly rate-controlled atrial fibrillation, presented with worsening dyspnoea. She had recently undergone single-chamber pacemaker insertion prior to an atrioventricular nodal (AVN) ablation, owing to failure in achieving successful CRT coronary sinus lead placement. She had clinical evidence of volume overload, and her electrocardiogram demonstrated right ventricular pacing. Echocardiography demonstrated left ventricular (LV) impairment, with an ejection fraction (EF) of 35%, and severe functional mitral regurgitation (MR). Her diagnosis was overall consistent with pacing-induced cardiomyopathy (PIC). In this patient, the use of right ventriculography, using power-injector-delivered contrast, successfully facilitated placement of an LBBAP lead, with confirmation of good threshold and sensing parameters. Following an upgrade to conduction system pacing, the patient recovered well. On recent follow-up, repeat echocardiography (24 months post initial presentation) demonstrated improved LV function (EF 45% from 35%) and only mild-to-moderate MR.</p><p><strong>Discussion: </strong>In conclusion, we demonstrate the utility of right ventriculography to facilitate placement of an LBBAP lead, successfully treating a patient who developed PIC from chronic right ventricular pacing following AVN ablation.</p>\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2024-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443961/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/ehjcr/ytae494\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae494","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:越来越多的证据表明,左束支区起搏(LBBAP)可替代传统的心脏再同步化疗法(CRT)。病例摘要:一名 79 岁的女性患者因呼吸困难加重而前来就诊,她患有心房颤动,心率控制不佳。由于 CRT 冠状窦导联置入失败,她最近在房室结消融术前接受了单腔起搏器置入术。她有容量超负荷的临床症状,心电图显示右心室起搏。超声心动图显示左心室功能受损,射血分数(EF)为 35%,功能性二尖瓣返流(MR)严重。她的诊断与起搏诱发心肌病(PIC)总体一致。在该患者中,使用功率注射器输送的造影剂进行右心室造影,成功地促进了 LBBAP 导联的置入,并确认了良好的阈值和传感参数。在升级为传导系统起搏后,患者恢复良好。在最近的随访中,重复超声心动图检查(初次就诊后 24 个月)显示左心室功能有所改善(EF 从 35% 升至 45%),只有轻度至中度 MR:总之,我们展示了右心室造影在促进 LBBAP 导联置入方面的实用性,成功治疗了一名在房室结消融术后因慢性右心室起搏而出现 PIC 的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
Right ventriculography to guide left bundle branch pacing in pacing-induced cardiomyopathy: a novel case report.

Background: There is emerging evidence for the potential utility of left bundle branch area pacing (LBBAP), as an alternative to conventional cardiac resynchronization therapy (CRT). The utility of right ventriculography by way of power injector to facilitate lead placement has not yet been reported in the literature.

Case summary: A 79-year-old female, with a background of poorly rate-controlled atrial fibrillation, presented with worsening dyspnoea. She had recently undergone single-chamber pacemaker insertion prior to an atrioventricular nodal (AVN) ablation, owing to failure in achieving successful CRT coronary sinus lead placement. She had clinical evidence of volume overload, and her electrocardiogram demonstrated right ventricular pacing. Echocardiography demonstrated left ventricular (LV) impairment, with an ejection fraction (EF) of 35%, and severe functional mitral regurgitation (MR). Her diagnosis was overall consistent with pacing-induced cardiomyopathy (PIC). In this patient, the use of right ventriculography, using power-injector-delivered contrast, successfully facilitated placement of an LBBAP lead, with confirmation of good threshold and sensing parameters. Following an upgrade to conduction system pacing, the patient recovered well. On recent follow-up, repeat echocardiography (24 months post initial presentation) demonstrated improved LV function (EF 45% from 35%) and only mild-to-moderate MR.

Discussion: In conclusion, we demonstrate the utility of right ventriculography to facilitate placement of an LBBAP lead, successfully treating a patient who developed PIC from chronic right ventricular pacing following AVN ablation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信