脊柱多体模拟,用于将 VBT 后的生物力学量客观化:概念验证和基线数据描述。

IF 2.6 3区 医学 Q2 CLINICAL NEUROLOGY
European Spine Journal Pub Date : 2024-11-01 Epub Date: 2024-09-29 DOI:10.1007/s00586-024-08480-7
Jil Frank, Miguel Pishnamaz, Dominika Ignasiak, Per David Trobisch, Frank Hildebrand, Maximilian Praster
{"title":"脊柱多体模拟,用于将 VBT 后的生物力学量客观化:概念验证和基线数据描述。","authors":"Jil Frank, Miguel Pishnamaz, Dominika Ignasiak, Per David Trobisch, Frank Hildebrand, Maximilian Praster","doi":"10.1007/s00586-024-08480-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Vertebral Body Tethering (VBT), an alternative treatment for adolescent idiopathic scoliosis, shows satisfactory post-operative results. However, the biomechanical quantities and consequences after VBT surgery remain largely unknown. Therefore, the aim of this study is to analyze the spinal biomechanics during different motions using a multibody simulation approach.</p><p><strong>Methods: </strong>The tether and intervertebral compression forces were simulated in a validated spine model during different physiological movements at different pre-tensions and screw positions, while considering the anatomical muscle and ligament properties.</p><p><strong>Results: </strong>The simulations showed that an augmentation of the pre-tension and an alteration of the screw position have both significant impact on the intervertebral compression and tether forces. The forces also vary depending on the movement performed, with the highest tether forces measured during lateral bending. In the upright position, with a pre-tension of 200 N, the maximum compression force increases by up to 157% compared to the untethered maximum compression force. The screw position can lead to large differences in the distribution of forces in the spine.</p><p><strong>Conclusion: </strong>The biomechanical data provide a first impression of the forces that occur along the spine during various physiological movements and are consistent with published clinical data. Forces are not evenly distributed along the spine, with higher lumbar forces. The tether forces reach values during lateral bending that can potentially destroy the tether´s integrity and thus may explain the common post-operative complication, namely tether breakage. The results of the model can therefore have an impact on future directions for improved surgical VBT treatment.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":" ","pages":"4049-4061"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A multibody simulation of the spine for objectification of biomechanical quantities after VBT: a proof of concept and description of baseline data.\",\"authors\":\"Jil Frank, Miguel Pishnamaz, Dominika Ignasiak, Per David Trobisch, Frank Hildebrand, Maximilian Praster\",\"doi\":\"10.1007/s00586-024-08480-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Vertebral Body Tethering (VBT), an alternative treatment for adolescent idiopathic scoliosis, shows satisfactory post-operative results. However, the biomechanical quantities and consequences after VBT surgery remain largely unknown. Therefore, the aim of this study is to analyze the spinal biomechanics during different motions using a multibody simulation approach.</p><p><strong>Methods: </strong>The tether and intervertebral compression forces were simulated in a validated spine model during different physiological movements at different pre-tensions and screw positions, while considering the anatomical muscle and ligament properties.</p><p><strong>Results: </strong>The simulations showed that an augmentation of the pre-tension and an alteration of the screw position have both significant impact on the intervertebral compression and tether forces. The forces also vary depending on the movement performed, with the highest tether forces measured during lateral bending. In the upright position, with a pre-tension of 200 N, the maximum compression force increases by up to 157% compared to the untethered maximum compression force. The screw position can lead to large differences in the distribution of forces in the spine.</p><p><strong>Conclusion: </strong>The biomechanical data provide a first impression of the forces that occur along the spine during various physiological movements and are consistent with published clinical data. Forces are not evenly distributed along the spine, with higher lumbar forces. The tether forces reach values during lateral bending that can potentially destroy the tether´s integrity and thus may explain the common post-operative complication, namely tether breakage. The results of the model can therefore have an impact on future directions for improved surgical VBT treatment.</p>\",\"PeriodicalId\":12323,\"journal\":{\"name\":\"European Spine Journal\",\"volume\":\" \",\"pages\":\"4049-4061\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Spine Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00586-024-08480-7\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08480-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:椎体拴系(VBT)是治疗青少年特发性脊柱侧凸的一种替代疗法,术后效果令人满意。然而,VBT 手术后的生物力学量和后果在很大程度上仍不为人所知。因此,本研究旨在使用多体模拟方法分析不同运动时的脊柱生物力学:方法:在一个经过验证的脊柱模型中模拟了不同预拉力和螺钉位置下不同生理运动过程中的系绳力和椎间压缩力,同时考虑了解剖肌肉和韧带的特性:模拟结果表明,预拉力的增加和螺钉位置的改变对椎间压缩力和系力都有显著影响。系力也因运动方式而异,侧弯时测得的系力最大。在直立位置,预拉力为 200 N 时,最大压缩力比未系绳时的最大压缩力增加了 157%。螺钉位置会导致脊柱中的力分布出现巨大差异:生物力学数据提供了在各种生理运动中脊柱受力的初步印象,与已公布的临床数据一致。脊柱受力分布不均,腰部受力较大。系绳力在侧弯过程中达到的值可能会破坏系绳的完整性,从而可能解释常见的术后并发症,即系绳断裂。因此,该模型的结果将对未来改进 VBT 手术治疗的方向产生影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A multibody simulation of the spine for objectification of biomechanical quantities after VBT: a proof of concept and description of baseline data.

Purpose: Vertebral Body Tethering (VBT), an alternative treatment for adolescent idiopathic scoliosis, shows satisfactory post-operative results. However, the biomechanical quantities and consequences after VBT surgery remain largely unknown. Therefore, the aim of this study is to analyze the spinal biomechanics during different motions using a multibody simulation approach.

Methods: The tether and intervertebral compression forces were simulated in a validated spine model during different physiological movements at different pre-tensions and screw positions, while considering the anatomical muscle and ligament properties.

Results: The simulations showed that an augmentation of the pre-tension and an alteration of the screw position have both significant impact on the intervertebral compression and tether forces. The forces also vary depending on the movement performed, with the highest tether forces measured during lateral bending. In the upright position, with a pre-tension of 200 N, the maximum compression force increases by up to 157% compared to the untethered maximum compression force. The screw position can lead to large differences in the distribution of forces in the spine.

Conclusion: The biomechanical data provide a first impression of the forces that occur along the spine during various physiological movements and are consistent with published clinical data. Forces are not evenly distributed along the spine, with higher lumbar forces. The tether forces reach values during lateral bending that can potentially destroy the tether´s integrity and thus may explain the common post-operative complication, namely tether breakage. The results of the model can therefore have an impact on future directions for improved surgical VBT treatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Spine Journal
European Spine Journal 医学-临床神经学
CiteScore
4.80
自引率
10.70%
发文量
373
审稿时长
2-4 weeks
期刊介绍: "European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts. Official publication of EUROSPINE, The Spine Society of Europe
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信