Nagendra Y Madisi, Sana Ali, Daniel Greenberg, Gowthami Kobbari, Muhammad Salick, Anoosh Parimi, Ziad Boujaoude, Wissam Abouzgheib
{"title":"一项多中心观察研究,评估 Bonastent 用于中央气道阻塞的安全性、可行性和并发症。","authors":"Nagendra Y Madisi, Sana Ali, Daniel Greenberg, Gowthami Kobbari, Muhammad Salick, Anoosh Parimi, Ziad Boujaoude, Wissam Abouzgheib","doi":"10.1177/17534666241260235","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Self-expandable metallic stents (SEMS) are increasingly used in the management of both malignant and nonmalignant airway stenosis. There are multiple stents available in the market; however, the current literature on the efficacy and safety of newly available 3rd generation SEMS (Bonastent) is extremely limited and only has data from single center studies.</p><p><strong>Objectives: </strong>To report the efficacy and early (<7 days) and late (⩾7 days) complications in patients with central airway obstruction (CAO) treated with Bonastent placement at two institutions.</p><p><strong>Design: </strong>We performed a retrospective analysis of data of consecutive patients who underwent therapeutic bronchoscopy and Bonastent placement at two tertiary care university hospitals between January 2019 and November 2023.</p><p><strong>Methods: </strong>Bonastent deployment was performed in the operating room. Stents were deployed using rigid or flexible bronchoscopy under direct visualization with a flexible bronchoscope and in conjunction with fluoroscopic guidance. We then analyzed the effectiveness, short-term, and long-term complications of Bonastent placement.</p><p><strong>Results: </strong>A total of 107 Bonastents® were placed in 96 patients. The most common etiology of CAO was malignancy, 92.7% (<i>n</i> = 89), followed by excessive dynamic airway collapse (EDAC) and post-intubation tracheal stenosis. Seventy-three patients (76%) had improvement in symptoms or imaging within 7 days of stent placement, including successful liberation from mechanical ventilation in a patient with CAO. Early complications occurred in seven patients (two-airway bleeding, two-mucus plugging that improved with airway clearance, two-stent migrations, and one-cough).Late complications occurred in 23 patients (1-stent migration requiring revision bronchoscopy and replacement of airway stent, 11-mucus plugging, 6-granulation tissue, 2-pneumonia, 1-cough, 1-tumor ingrowth/stent fracture, 1-airway emergency due to excessive granulation tissue obstructing the distal end of the stent and had a failed cricothyroidotomy leading to death). Overall, the early complication rate was 7.3% (7/96) and late complication rate was 23.9% (23/96).</p><p><strong>Conclusion: </strong>Our study is the first multicenter study that found a good safety profile with a low complication rate after tracheobronchial Bonastent placement with improvement in symptoms soon after stent placement.</p>","PeriodicalId":22884,"journal":{"name":"Therapeutic Advances in Respiratory Disease","volume":"18 ","pages":"17534666241260235"},"PeriodicalIF":3.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11437588/pdf/","citationCount":"0","resultStr":"{\"title\":\"A multicenter observational study assessing the safety, feasibility, and complications of Bonastent in central airway obstruction.\",\"authors\":\"Nagendra Y Madisi, Sana Ali, Daniel Greenberg, Gowthami Kobbari, Muhammad Salick, Anoosh Parimi, Ziad Boujaoude, Wissam Abouzgheib\",\"doi\":\"10.1177/17534666241260235\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Self-expandable metallic stents (SEMS) are increasingly used in the management of both malignant and nonmalignant airway stenosis. There are multiple stents available in the market; however, the current literature on the efficacy and safety of newly available 3rd generation SEMS (Bonastent) is extremely limited and only has data from single center studies.</p><p><strong>Objectives: </strong>To report the efficacy and early (<7 days) and late (⩾7 days) complications in patients with central airway obstruction (CAO) treated with Bonastent placement at two institutions.</p><p><strong>Design: </strong>We performed a retrospective analysis of data of consecutive patients who underwent therapeutic bronchoscopy and Bonastent placement at two tertiary care university hospitals between January 2019 and November 2023.</p><p><strong>Methods: </strong>Bonastent deployment was performed in the operating room. Stents were deployed using rigid or flexible bronchoscopy under direct visualization with a flexible bronchoscope and in conjunction with fluoroscopic guidance. We then analyzed the effectiveness, short-term, and long-term complications of Bonastent placement.</p><p><strong>Results: </strong>A total of 107 Bonastents® were placed in 96 patients. The most common etiology of CAO was malignancy, 92.7% (<i>n</i> = 89), followed by excessive dynamic airway collapse (EDAC) and post-intubation tracheal stenosis. Seventy-three patients (76%) had improvement in symptoms or imaging within 7 days of stent placement, including successful liberation from mechanical ventilation in a patient with CAO. Early complications occurred in seven patients (two-airway bleeding, two-mucus plugging that improved with airway clearance, two-stent migrations, and one-cough).Late complications occurred in 23 patients (1-stent migration requiring revision bronchoscopy and replacement of airway stent, 11-mucus plugging, 6-granulation tissue, 2-pneumonia, 1-cough, 1-tumor ingrowth/stent fracture, 1-airway emergency due to excessive granulation tissue obstructing the distal end of the stent and had a failed cricothyroidotomy leading to death). Overall, the early complication rate was 7.3% (7/96) and late complication rate was 23.9% (23/96).</p><p><strong>Conclusion: </strong>Our study is the first multicenter study that found a good safety profile with a low complication rate after tracheobronchial Bonastent placement with improvement in symptoms soon after stent placement.</p>\",\"PeriodicalId\":22884,\"journal\":{\"name\":\"Therapeutic Advances in Respiratory Disease\",\"volume\":\"18 \",\"pages\":\"17534666241260235\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11437588/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Respiratory Disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17534666241260235\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Respiratory Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17534666241260235","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
A multicenter observational study assessing the safety, feasibility, and complications of Bonastent in central airway obstruction.
Background: Self-expandable metallic stents (SEMS) are increasingly used in the management of both malignant and nonmalignant airway stenosis. There are multiple stents available in the market; however, the current literature on the efficacy and safety of newly available 3rd generation SEMS (Bonastent) is extremely limited and only has data from single center studies.
Objectives: To report the efficacy and early (<7 days) and late (⩾7 days) complications in patients with central airway obstruction (CAO) treated with Bonastent placement at two institutions.
Design: We performed a retrospective analysis of data of consecutive patients who underwent therapeutic bronchoscopy and Bonastent placement at two tertiary care university hospitals between January 2019 and November 2023.
Methods: Bonastent deployment was performed in the operating room. Stents were deployed using rigid or flexible bronchoscopy under direct visualization with a flexible bronchoscope and in conjunction with fluoroscopic guidance. We then analyzed the effectiveness, short-term, and long-term complications of Bonastent placement.
Results: A total of 107 Bonastents® were placed in 96 patients. The most common etiology of CAO was malignancy, 92.7% (n = 89), followed by excessive dynamic airway collapse (EDAC) and post-intubation tracheal stenosis. Seventy-three patients (76%) had improvement in symptoms or imaging within 7 days of stent placement, including successful liberation from mechanical ventilation in a patient with CAO. Early complications occurred in seven patients (two-airway bleeding, two-mucus plugging that improved with airway clearance, two-stent migrations, and one-cough).Late complications occurred in 23 patients (1-stent migration requiring revision bronchoscopy and replacement of airway stent, 11-mucus plugging, 6-granulation tissue, 2-pneumonia, 1-cough, 1-tumor ingrowth/stent fracture, 1-airway emergency due to excessive granulation tissue obstructing the distal end of the stent and had a failed cricothyroidotomy leading to death). Overall, the early complication rate was 7.3% (7/96) and late complication rate was 23.9% (23/96).
Conclusion: Our study is the first multicenter study that found a good safety profile with a low complication rate after tracheobronchial Bonastent placement with improvement in symptoms soon after stent placement.