{"title":"使用两种不同类型的输入轮廓对基于深度学习的头颈癌患者剂量预测进行评估","authors":"Masahide Saito, Noriyuki Kadoya, Yuto Kimura, Hikaru Nemoto, Ryota Tozuka, Keiichi Jingu, Hiroshi Onishi","doi":"10.1002/acm2.14519","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>This study evaluates deep learning (DL) based dose prediction methods in head and neck cancer (HNC) patients using two types of input contours.</p>\n </section>\n \n <section>\n \n <h3> Materials and methods</h3>\n \n <p>Seventy-five HNC patients undergoing two-step volumetric-modulated arc therapy were included. Dose prediction was performed using the AIVOT prototype (AiRato.Inc, Sendai, Japan), a commercial software with an HD U-net-based dose distribution prediction system. Models were developed for the initial plan (46 Gy/23Fr) and boost plan (24 Gy/12Fr), trained with 65 cases and tested with 10 cases. The 8-channel model used one target (PTV) and seven organs at risk (OARs), while the 10-channel model added two dummy contours (PTV ring and spinal cord PRV). Predicted and deliverable doses, obtained through dose mimicking on another radiation treatment planning system, were evaluated using dose-volume indices for PTV and OARs.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>For the initial plan, both models achieved approximately 2% prediction accuracy for the target dose and maintained accuracy within 3.2 Gy for OARs. The 10-channel model outperformed the 8-channel model for certain dose indices. For the boost plan, both models exhibited prediction accuracies of approximately 2% for the target dose and 1 Gy for OARs. The 10-channel model showed significantly closer predictions to the ground truth for D50% and Dmean. Deliverable plans based on prediction doses showed little significant difference compared to the ground truth, especially for the boost plan.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>DL-based dose prediction using the AIVOT prototype software in HNC patients yielded promising results. While additional contours may enhance prediction accuracy, their impact on dose mimicking is relatively small.</p>\n </section>\n </div>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"25 12","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.14519","citationCount":"0","resultStr":"{\"title\":\"Evaluation of deep learning based dose prediction in head and neck cancer patients using two different types of input contours\",\"authors\":\"Masahide Saito, Noriyuki Kadoya, Yuto Kimura, Hikaru Nemoto, Ryota Tozuka, Keiichi Jingu, Hiroshi Onishi\",\"doi\":\"10.1002/acm2.14519\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>This study evaluates deep learning (DL) based dose prediction methods in head and neck cancer (HNC) patients using two types of input contours.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and methods</h3>\\n \\n <p>Seventy-five HNC patients undergoing two-step volumetric-modulated arc therapy were included. Dose prediction was performed using the AIVOT prototype (AiRato.Inc, Sendai, Japan), a commercial software with an HD U-net-based dose distribution prediction system. Models were developed for the initial plan (46 Gy/23Fr) and boost plan (24 Gy/12Fr), trained with 65 cases and tested with 10 cases. The 8-channel model used one target (PTV) and seven organs at risk (OARs), while the 10-channel model added two dummy contours (PTV ring and spinal cord PRV). Predicted and deliverable doses, obtained through dose mimicking on another radiation treatment planning system, were evaluated using dose-volume indices for PTV and OARs.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>For the initial plan, both models achieved approximately 2% prediction accuracy for the target dose and maintained accuracy within 3.2 Gy for OARs. The 10-channel model outperformed the 8-channel model for certain dose indices. For the boost plan, both models exhibited prediction accuracies of approximately 2% for the target dose and 1 Gy for OARs. The 10-channel model showed significantly closer predictions to the ground truth for D50% and Dmean. Deliverable plans based on prediction doses showed little significant difference compared to the ground truth, especially for the boost plan.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>DL-based dose prediction using the AIVOT prototype software in HNC patients yielded promising results. While additional contours may enhance prediction accuracy, their impact on dose mimicking is relatively small.</p>\\n </section>\\n </div>\",\"PeriodicalId\":14989,\"journal\":{\"name\":\"Journal of Applied Clinical Medical Physics\",\"volume\":\"25 12\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-09-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.14519\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Clinical Medical Physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/acm2.14519\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.14519","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Evaluation of deep learning based dose prediction in head and neck cancer patients using two different types of input contours
Purpose
This study evaluates deep learning (DL) based dose prediction methods in head and neck cancer (HNC) patients using two types of input contours.
Materials and methods
Seventy-five HNC patients undergoing two-step volumetric-modulated arc therapy were included. Dose prediction was performed using the AIVOT prototype (AiRato.Inc, Sendai, Japan), a commercial software with an HD U-net-based dose distribution prediction system. Models were developed for the initial plan (46 Gy/23Fr) and boost plan (24 Gy/12Fr), trained with 65 cases and tested with 10 cases. The 8-channel model used one target (PTV) and seven organs at risk (OARs), while the 10-channel model added two dummy contours (PTV ring and spinal cord PRV). Predicted and deliverable doses, obtained through dose mimicking on another radiation treatment planning system, were evaluated using dose-volume indices for PTV and OARs.
Results
For the initial plan, both models achieved approximately 2% prediction accuracy for the target dose and maintained accuracy within 3.2 Gy for OARs. The 10-channel model outperformed the 8-channel model for certain dose indices. For the boost plan, both models exhibited prediction accuracies of approximately 2% for the target dose and 1 Gy for OARs. The 10-channel model showed significantly closer predictions to the ground truth for D50% and Dmean. Deliverable plans based on prediction doses showed little significant difference compared to the ground truth, especially for the boost plan.
Conclusion
DL-based dose prediction using the AIVOT prototype software in HNC patients yielded promising results. While additional contours may enhance prediction accuracy, their impact on dose mimicking is relatively small.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic