积极应用光疗的自刻蚀粘合剂的釉质粘接强度:一项试点研究

IF 0.7 4区 材料科学 Q4 MATERIALS SCIENCE, CHARACTERIZATION & TESTING
M. K. Ayar, Ö. Yeşil
{"title":"积极应用光疗的自刻蚀粘合剂的釉质粘接强度:一项试点研究","authors":"M. K. Ayar, Ö. Yeşil","doi":"10.1007/s11223-024-00681-1","DOIUrl":null,"url":null,"abstract":"<p>The present study assessed the effect of the active application of self-etch adhesives with phototherapy on enamel bond strength. Sixty bovine incisors, individually embedded in acrylic blocks, were divided into two groups according to the adhesive system used: Group 1 (AEO) Adper Easy One and Group 2 (CSEP) Clearfil SE Protect. According to the application technique of self-etch adhesives, each main group was further divided into three subgroups (<i>n</i> =10): (PA) passive application, (AP) active application, and (PAA) phototherapy active application. Shear bond strength (SBS) tests were conducted using a universal testing machine. The data were analyzed via two-way ANOVA and posthoc multiple comparisons using the Tukey HSD test. Furthermore, statistical analysis of the distribution of failure modes was carried out using the χ<sup>2</sup> test (<i>p</i> &lt; 0.05). Two-way ANOVA indicated no significant differences in either adhesive systems (<i>p</i> = 0.797) or application technique (<i>p</i> = 0.869). Similarly, a χ<sup>2</sup> test showed no significant difference in the distribution of failure modes concerning surface treatments (<i>p</i> = 0.905). The use of phototherapy as a diode laser for the active application of the tested self-etch adhesives in the present study exhibited similar initial enamel bonding performance to conventional application methods.</p>","PeriodicalId":22007,"journal":{"name":"Strength of Materials","volume":"9 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enamel Bond Strength of Self-Etch Adhesives with Phototherapy Active Application: a Pilot Study\",\"authors\":\"M. K. Ayar, Ö. Yeşil\",\"doi\":\"10.1007/s11223-024-00681-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The present study assessed the effect of the active application of self-etch adhesives with phototherapy on enamel bond strength. Sixty bovine incisors, individually embedded in acrylic blocks, were divided into two groups according to the adhesive system used: Group 1 (AEO) Adper Easy One and Group 2 (CSEP) Clearfil SE Protect. According to the application technique of self-etch adhesives, each main group was further divided into three subgroups (<i>n</i> =10): (PA) passive application, (AP) active application, and (PAA) phototherapy active application. Shear bond strength (SBS) tests were conducted using a universal testing machine. The data were analyzed via two-way ANOVA and posthoc multiple comparisons using the Tukey HSD test. Furthermore, statistical analysis of the distribution of failure modes was carried out using the χ<sup>2</sup> test (<i>p</i> &lt; 0.05). Two-way ANOVA indicated no significant differences in either adhesive systems (<i>p</i> = 0.797) or application technique (<i>p</i> = 0.869). Similarly, a χ<sup>2</sup> test showed no significant difference in the distribution of failure modes concerning surface treatments (<i>p</i> = 0.905). The use of phototherapy as a diode laser for the active application of the tested self-etch adhesives in the present study exhibited similar initial enamel bonding performance to conventional application methods.</p>\",\"PeriodicalId\":22007,\"journal\":{\"name\":\"Strength of Materials\",\"volume\":\"9 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strength of Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1007/s11223-024-00681-1\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strength of Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1007/s11223-024-00681-1","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了积极应用自酸蚀粘合剂和光疗对牙釉质粘接强度的影响。根据所使用的粘合剂系统,将单独嵌入丙烯酸块的 60 颗牛门牙分为两组:第一组(AEO)为 Adper Easy One,第二组(CSEP)为 Clearfil SE Protect。根据自酸蚀粘接剂的应用技术,每个主组又分为三个亚组(n = 10):(PA)被动应用组、(AP)主动应用组和(PAA)光疗主动应用组。使用万能试验机进行剪切粘接强度(SBS)测试。数据采用双向方差分析,并使用 Tukey HSD 检验进行事后多重比较。此外,还使用 χ2 检验(p < 0.05)对失效模式的分布进行了统计分析。双向方差分析表明,粘合剂系统(p = 0.797)和应用技术(p = 0.869)均无显著差异。同样,χ2 检验表明,表面处理的失效模式分布也无明显差异(p = 0.905)。在本研究中,使用二极管激光进行光疗来主动涂抹测试的自酸蚀粘合剂与传统涂抹方法的初始釉质粘结性能相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Enamel Bond Strength of Self-Etch Adhesives with Phototherapy Active Application: a Pilot Study

Enamel Bond Strength of Self-Etch Adhesives with Phototherapy Active Application: a Pilot Study

The present study assessed the effect of the active application of self-etch adhesives with phototherapy on enamel bond strength. Sixty bovine incisors, individually embedded in acrylic blocks, were divided into two groups according to the adhesive system used: Group 1 (AEO) Adper Easy One and Group 2 (CSEP) Clearfil SE Protect. According to the application technique of self-etch adhesives, each main group was further divided into three subgroups (n =10): (PA) passive application, (AP) active application, and (PAA) phototherapy active application. Shear bond strength (SBS) tests were conducted using a universal testing machine. The data were analyzed via two-way ANOVA and posthoc multiple comparisons using the Tukey HSD test. Furthermore, statistical analysis of the distribution of failure modes was carried out using the χ2 test (p < 0.05). Two-way ANOVA indicated no significant differences in either adhesive systems (p = 0.797) or application technique (p = 0.869). Similarly, a χ2 test showed no significant difference in the distribution of failure modes concerning surface treatments (p = 0.905). The use of phototherapy as a diode laser for the active application of the tested self-etch adhesives in the present study exhibited similar initial enamel bonding performance to conventional application methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Strength of Materials
Strength of Materials MATERIALS SCIENCE, CHARACTERIZATION & TESTING-
CiteScore
1.20
自引率
14.30%
发文量
89
审稿时长
6-12 weeks
期刊介绍: Strength of Materials focuses on the strength of materials and structural components subjected to different types of force and thermal loadings, the limiting strength criteria of structures, and the theory of strength of structures. Consideration is given to actual operating conditions, problems of crack resistance and theories of failure, the theory of oscillations of real mechanical systems, and calculations of the stress-strain state of structural components.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信